abc COMBO 25 Bedienungsanleitung

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED
FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL
ABC COMBO

1.Technical specifications
DESCRIPTION
Frequency
Width
Height
Debth
- Pellet
- Wood
UNIT
Boiler power
Water content in a boiler
Required draft
Supply electrical power:
- Ignition stage
- Operation stage
Supply voltage
Boiler weight
Maximum operating pressure
Maximum operating temperature
Flue pipe diameter
Boiler dimensions
Boiler
connectors
Supply line
Return line
Charging
and discharging
Fuel dimensions:
Pellet storage capacity
1
kw 25 40
lit 80 100
Pa 12 14
W 370 480
W 70 180
V 230 230
Hz 50 50
kg 280 360
bar 2,5 2,5
°C 85 85
mm 100 120
mm 827 986
mm 1371 1539
mm 988 1052
Col 1 5/4
Col 1 5/4
Col 1/2 1/2
mm 30x6 30x6
mm 100x100x350 100x100x400
L 170 250
COMBO 25 COMBO 40 COMBO 60
60
120
16
480
180
230
50
410
2,5
85
120
986
1524
1202
5/4
5/4
1/2
30x6
100x100x500
340

2. Display: Functions and use
Figure 1
ON/OFF and resetting alarm
Visualization/Increasing values
Locking the keypad
Visualization/Decreasing values
Buttons
P1 Exit from the menu or sub-menu
P2
P3
P4
P5
P6
Short press Long press (3-5 seconds)
Activating Chrono function within the
Chrono menu
Entering the main menu, saving setup,
activating time setup Entering the system menu,
setting up the keypad
-
-
-
-
LED lights
L1 Heater turned on
L2 Motor – reduction gear turned on
L3 V2 output active - Pump
L4 AUX 1 output active
L5 AUX 2 output active
L10 Pellet level sensor turned on
L11 Auxiliary input active
L12 Micro-switch turned on
2
P1
P2
P3
P4
P5
P6

3.Alarms
4.Visualization
- Exhaust gas temperature
- The water temperature in the boiler
- The water temperature in the ,,Buffer,,
- Fan speed
- illumination
- Number of admissions
- Software serial number
Exhaust Temp: 103
Boiler Temp: 25
Buffer Temp: 25
Fan Speed : 1000
Flame Light: 0
Recipe [nr]: 1
Product Code: 488: 1234
5.User menu
This menu is accessed by short pressing the button P3
3
DESCRIPTION STATUS NUMBER
Blocked Er1
Er2
Er3
Er4
Er5
Er7
Er8
Er11
Er12
Er15
Er16
Er18
Er52
Prob
Safety thermostat HV1
Boiler door opened
Turning off due to lack of fire
Turning off due to excessive temperature in the boiler
Turning off due to excessive temperature of exhaust
Error in encoder: no signal
Error in encoder: failed fan control
Error in real time
Failed ignition
Failure of main power supply
RS 485 connecting error
Lack of pellet in the storage
Micro-switch error
Failure in probe control during the “Check Up” stage
Resetting of all alarms is performed by long pressing the button P2
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked
Blocked

5.1 Combustion power settings
Combustion power can be set via this menu. Setting mode may be manual or
automatic. In the first case the user sets the power by himself, while in the other the
system sets the combustion power in relation to the defined temperature.
Pellet: 1-2-3-4-5-Auto
Wood: 0-1-2-3-4-5-Auto
5.2 Thermostats
These are used to adjust the set temperature in the boiler and/or “Buffer”, if installed.
“Buffer”-thermostat is visible only if P26=1 and P42=1
5.3 Operation mode
This menu enables the user to choose the boiler operation mode: pellet or solid fuel.
Changing the operation mode is possible only when the boiler is turned off.
5.4 Recipe
This menu is visible only when the boiler operation mode is “pellets” and the recipe
change is not allowed.
Only “Pellet recipe” 1 is available.
5.5 Chrono
It is used to set the time of ignition and shutdown of the boiler. Press the button P3
to enter the menu.
4

5.5.1 Modality
It is used to activate and deactivate the program settings.
Press button P3
5
Press button P3 and choose Daily, Weekly or Week End program using the buttons
P4 or P6. Activation of Chrono program is done by pressing the button P3 (selected
field flashes) and then the button P2 (Disabled changes to Enabled)

5.5.2 Chrono Program
Press the button P1 to return one step back and select the field Chrono Program.
Press button P3 to enter the menu
Choose Daily, Weekly or Week End program using the buttons
P4 or P6 and press the button P3 to confirm
Select the day of the week using the buttons P4 or P6 and press
the button P3 to confirm.
6

Within each day there are three programs that can be used. Press the button P3
(selected field flashes) and set the time of ignition of the boiler (ON)
using the buttons P4 or P6. After setting the time press the button P3 to confirm.
Press the button P6 to move to the field for boiler shutdown. Press the button
P3 (selected field flashes) and using the buttons P4 or P6
set the boiler shutdown time.
7

Press the button P5 (symbol “√” appears) and setting of time for a specific day of a
week is now activated.
Press button P1 until the display shows the initial screen. The symbol indicating that
the Chrono program is active now appears in top left corner of the screen.
Programming for operation around midnight
Set the clock to ON for the previous day at a specified time: for example, at 20:30
Set the clock to OFF for the previous day at 23:59
Set the clock to ON for the next day at 00:00
Set the clock to OFF for the next day at a specified time: for example, at 6:30
Thy system turns on on Tuesday at 20:30 and turns off on Wednesday at 6:30.
8

5.5.3 Manual charging with pellets / Load
This option activates manual charging with pellets, while the motor-reducer works
non-stop. Charging stops automatically after 600 seconds or by manual deactivation
at any time by pressing OFF via the button P3.
Activating this function is only possible when the boiler is switched off.
Manual charging with pellets is only used during start-up of the boiler or when there
are on pellets in the storage.
5.5.4 Correction of charging with pellets / Calibration
This function is used to fine-tune the selected combustion power. The range of
correction is from -7 to +7
Example:
1. If the set combustion power level 3 is not sufficient and power level 4 is too much
power in such a case a correction of power level 3 can be made by +1 or 2 or power
level 4 by -1 or 2.
2. The correction can be made even when the pellet is of poor quality and there is a
large ash residue.
6. User Menu 2
This menu is accessed by long pressing the button P3.
6.1 Keyboard settings
6.1.1 Date and Time
In this menu you can adjust the day, month, year and hour.
6.1.2 Language
This menu is used to load data from the motherboard.
9
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Beliebte Kessel Handbücher anderer Marken

Vaillant
Vaillant uniSTOR VIH SW GB 500 BES Bedienungsanleitung

Radijator
Radijator BIO max 23.1 Bedienungsanleitung

Brunner
Brunner BSV 20 Bedienungsanleitung

Buderus
Buderus Logamax GB062-24 KDE H V2 Bedienungsanleitung

Potterton
Potterton 50e Datenblatt

UTICA BOILERS
UTICA BOILERS TriFire Bedienungsanleitung