Abloy DA460 Leitfaden

Abloy Oy
An ASSA ABLOY Group company
ABLOY® DA460 SWING DOOR OPERATOR
Installation and commissioning manual
All manuals and user guides at all-guides.com
all-guides.com

2
------------------- THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS -------------------
Warning - IT IS IMPORTANT FOR SAFETY OF PERSONS TO FOLLOW THESE INSTRUCTIONS.
-------------------------------------------- SAVE THESE INSTRUCTIONS --------------------------------------------
Warning! Warning!
Do not allow children to play with fixed controls.
Frequently examine the installation for imbalance and signs of wear or damage to cables, springs and
mountings. Do not use if repair or adjustment is necessary.
Disconnect the supply when cleaning or other maintenance is being carried out.
Before installing the operator, chec that the door is in good mechanical condition and it opens and
closes properly.
Ensure that entrapment between door and the surroundings is avoided.
Ensure that the operator is suited for installation. Chec temperature, humidity, door weights, etc.
restriction, what is mentioned in this manual or other Abloy® Oy material.
Note!
Instructions, design specifications and illustrations which are contained in this manual are not binding.
Rights reserved for changes without previous notice.
APPROVALS STANDARDS
Low Voltage directive 73/23/EEC as amended by the directive 93/68/EEC
EMC directive 89/336/EEC
Statement of fire doors by Technical Research Centre of Finland
All manuals and user guides at all-guides.com

3
CONTENTS
Approvals......................................................................................... 2
Revision.........................................................................................4
Content of delivery....................................................................... 5
General information...................................................................................6
Operation................................................................................. 7
Main switch and mode switch..................................................................7
Door weight.................................................................................8
Installation..........................................................................9
Internal connections..................................................................... 14
Commissioning............................................................................. 15
A safe door................................................................................................. 18
External connections.................................................................... 19
Connection examples............................................................................... 21
Self diagnostic...............................................................................28
Maintenance............................................................................ 29
Spare parts.....................................................................................30
All manuals and user guides at all-guides.com

4
REVISION
Following pages has been revised:
Page Revision
12, 13 The lenght of sliding arm has increased. Pictures has been updated.
As at 29.02.2008.
All manuals and user guides at all-guides.com

5
DA460 Swing door operator
- screws 4 pcs M8x22
DA103 Mounting plate
- screws 6 pcs 5,5x32
DA147 Standard arm
- screws 2 pcs 5,5x32
and 1 pcs M8x30
DA148 Extended arm
- screws 2 pcs 5,5x32
and 1 pcs M8x30
DA149 Sliding arm
- screws 2 pcs 5,5x50
and 1 pcs M8x30
DA150 Extension piece
- 10 mm + M8x35
- 20 mm + M8x35 + M8x45
- 60 mm + M8x90
CONTENT OF DELIVERY
All manuals and user guides at all-guides.com

6
GENERAL INFORMATION
Technical data
Measures
595 (L) x 85 (H) x 107 (W) mm
Weight 6,5 g
Supply voltage 90-264 VAC, 47-63 Hz
Rated output 70 W
Enclosure class IP20
Temperature range
Storage -30...+85°C (in dry premises)
Operation: -15...+50°C (in dry premises)
The automatic swing door operator must not be installed in applications
where it is subjected to water or snow.
Interfaces
Voltage output 24 VDC, stabilized, output current 500 mA
Voltage output 12 VDC, stabilized, output current 1,0 A
The total load must not exceed 12W
Potential free relay output, preset to operate 2 seconds
2 A @ 30 VDC resistive load
Features
Usage for heavy density of pedestrian traffic
Push&Go as a standard feature
Normal and delayed impulse
Adjustable hold open time 0...60 s or sequential use
Fire detector connection
Free Swing operation
Door hold force
Prepull before opening
Secondary DC inlet for power bac up (24 VDC (±15 %), 3A)
Maximum opening angles:
With standard arm 100 degrees
With sliding arm on the opening side 100 degrees
With sliding arm on the closing side 90 degrees
All manuals and user guides at all-guides.com
all-guides.com

7
OPERATION
Abloy® DA460 is an electromechanical swing door operator for heavy use. The
door operator includes new free swing function: when using the door manually it
operates lightly without motors resistance and the door can be left in open position
when required. It can be used on both single and double, internal and external,
fire and emergency exit doors.
Safety features
Opening cycle: If the door is obstructed in opening cycle. The door is set free and
hold open time is started. After 1 second, new trial is done to open the door.
Maximum amount for trials is 4. If this is exceeded or hold open time is end, the
door is closed.
Closing cycle: If the door is obstructed in closing cycle. The door is set free and
4 new trials are done to close the door. If the closing is still obstructed,
the operator tries to close the door at one minute intervals.
AUTO
MAN
OPEN
MAIN SWITCH AND MODE SWITCH
Main switch Mode switch
When the power is switched on, the mains switch lights up.
1= on 0= off
Functions of mode switch
AUTO:
The operator opens the door for the duration of the hold open time.
MAN:
Manual use.
OPEN:
The door is held permanetly open.
NOTE! There is 3 seconds constant delay when mode switch is
changed from position OPEN to AUTO or MAN.
All manuals and user guides at all-guides.com

8
Standard arm
50
60
70
80
90
100
110
120
130
140
150
160
170
180
60 70 80 90 100 110 120 130 140 150
Door weight [ g]
Door width [cm]
Sliding arm
Door wi th [cm]
50
60
70
80
90
100
110
120
130
140
150
160
170
180
60 70 80 90 100 110 120 130 140 150
Door weight [ g]
DOOR WEIGHT
All manuals and user guides at all-guides.com

9
INSTALLATION
Tools required
Drill
Set of ball ended allen wrenches
# 2 Phillips head screwdriver
Flat blade screwdrivers, 2 pcs
Steps of installation
- Preparing installation
- Installing the mounting plate
- Mounting the operator and the arm
- Connecting the operator to mains
- Commissioning
- Testing
- Connecting impulse devices
Preparing installation
- Chec the proper function of the door
- hinges
- door clearance
- Chec the proper function of the loc
- loc case
- stri er plate
Removal of housing
Note! Remove the protective earth wire from cover and connect it bac after
installation.
Keep the mains disconnected when removing or mounting cover.
All manuals and user guides at all-guides.com

10
Installing the mounting plate
Operator is to be installed on the transom, with the main switch located towards
the hinge.
Use the mounting plate DA103 with the door operator ensuring the installation
base is level and securely fixed to a flat surface.
Installation measurements for standard arm and for sliding arm DA149 to the
closing side installation.
When installing operator to the opening side of the door, refer to page 13.
Hinge line
63 296,5 530 593
28,5
28,5 13
41,5
70
83
39,5
o 30
10
o 10
o 10 o 10
All manuals and user guides at all-guides.com
Andere Handbücher für DA460
2
Inhaltsverzeichnis
Andere Abloy Garagentoröffner Handbücher
Beliebte Garagentoröffner Handbücher anderer Marken

Craftsman
Craftsman 139.53924 Bedienungsanleitung

Chamberlain
Chamberlain MyQ 940ESTD Bedienungsanleitung

Automatic Technology
Automatic Technology GDO-9V1 SecuraLift Bedienungsanleitung

Westfalia
Westfalia 19 36 07 Bedienungsanleitung

Chamberlain
Chamberlain HD520EVP Bedienungsanleitung

Cardin
Cardin BL Series Bedienungsanleitung