Adkins Studio Plate Service-Handbuch

operators handbook
The Future of Heat press technology...
Studio
Plate
Heat
press

Copyrights
© 2012 A. Adkins & Sons Limited, High Cross, Lancaster Road,
Hinckley, Leicestershire.
Studio Plate Press is the registered trademark of A. Adkins & Sons
Limited.
No part of this publication may be reproduced by any means without the
prior written permission of A. Adkins & Sons Limited.

Preface
Dear User
Welcome to the growing group of Adkins Studio Plate Press users.
The product you have purchased has been carefully designed and
manufactured to ensure that you, the user, will gain the maximum
benefit.
All Adkins products are specifically designed to ensure ease of use
with particular attention to safety requirements.
Should you discover any fault or damage upon receipt of this
product, you should immediately contact your supplier.

Contents
1. Introduction Studio Plate Press 1
1.1 Specifications of the Studio Plate Press 2
1.2 Safety Tips 3
2. Installation 4
2.1 Transport instructions 4
2.2 Installing the machine 4
2.3 Electrical requirements 4
2.4 Adjusting the pressure 5
3. How to operate the Studio Plate Press 6
3.1 Starting with the Studio Plate Press 6
3.2 Working with heat transfer materials 6
3.3 Pressing pad assembly 7
3.4 Shutting down the machine 7
4. Maintenance of the Machine 8
4.1 Daily maintenance 8
4.2 Periodic maintenance 8
4.3 Cleaning 8
5. Machine Drawings and Diagrams 9
5.1 General Layout 10
5.2 Control Unit operation 11
5.3 Exploded Diagram and Parts List 12
6. Design Change 13
7. Guarantee (Limited Warranty) 14
Declaration of Conformity 15

Page 1
1. Introduction Studio Plate
Press
The Studio Plate press is a budget priced press suitable for most low
and medium pressure operations. This simple robust machine has digital
controls for both heat and dwell accuracy and ease of operation but
requires only minimal operating space.
The work area of the Studio Plate press is 11.5 cm and/or 15 cm
diameter (4.5 in and/or 6 in diameter).
The Studio Plate press is produced in two versions, nominally 230
Volts AC for the ‘European’ market and nominally 110 Volts AC for
the ‘American’ market.

Page 2
1.1 Specifications of the Studio Plate Press
The Studio Plate Press is a manually operated heat press for transfer
printing and material fusing. It is ideal for medium volume production.
The work area of the Studio Plate Press is 11.5 cm and/or 15 cm
diameter (4.5 in and/or 6 in diameter).
Specifications European
Machine USA Machine
Power consumption 250 Watts 250 Watts
Power supply 230 Volts AC 110 Volts AC
Max. working temperature 260oC 500oF
Display timer range 0 - 9999 sec 0 - 9999 sec
Machine height open 56 cm 22 in
Machine height closed 45 cm 18 in
Machine width 17 cm 6.5 in
Machine depth 27 cm 10.5 in
Net weight 11 kg 24 lbs
Press pad dimensions 11.5 cm and/or 15 cm
diameter 4.5 ins and/or 6 in
diameter
Fuses 3A 3A

Page 3
1.2 Safety Tips
Our customer service department has its own service
engineers and, if required, maintenance is available.
The Studio Plate Press meets the European Legislation
standard. Under normal conditions accidents are rare.
However listed below are some practical points to ensure your
safety.
Always use both hands when opening or closing the press
for positive control of the movement of the handle.
Always switch off the current (and pull plug out of the
socket) when undertaking maintenance work or when
cleaning the machine.
Ensure that there is sufficient space around the machine.
Cables and connections must not get jammed. Although
the heat radiation of the press is low, there should be
enough space for cooling down.
Avoid contact with the heat plate.
DO NOT REMOVE THE INSTRUMENT COVER
UNLESS QUALIFIED TO DO SO - touching internal parts
is dangerous and may cause shock hazard. All electrical
connections inside covers are live. Never operate Press with
any covers and/or guards removed.
PROTECT THE MAINS CABLE - damage to the mains
cable may cause fire or shock hazard. When unplugging, hold
by the plug only and remove carefully. Take care that the
mains cable does not come into contact with the heat plate (or
moving parts of the mechanism) during operation of the
machine.
OPERATING AMBIENT TEMPERATURE RANGE - the
operating ambient temperature range is 32oF - 104oF, (0oC -
35oC) and humidity of 20 - 80%.
MACHINE FUSES - type: ultra-rapid (FF) fuses 1¼” 240
Vac max. 3 Amps. (110 Vac max. 3 amps)
WARNING - THIS APPARATUS MUST BE EARTHED
(GROUNDED)
CAUTION
This machine gets hot whilst operating. Take care not to touch
any surfaces that are labelled “Caution this plate is HOT”.
MACHINE OPERATION
Only persons trained to do so should operate this machine.

Page 4
2. Installation
2.1 Transport instructions
The machine comes to you either shrink-wrapped or in a box. If you
have to transport the machine at any time it is recommended that you
use a similar box and packing method. Please let the machine cool
down and lower the handle to the locked position.
2.2 Installing the machine
2.2.1 Remove all packaging from the heat press.
2.2.2 Check to ensure that no damage has been caused to the
machine during transit.
2.2.3 Place the machine on a sturdy horizontal surface that is within
easy reach of the operator and allow space for the handle to
move up to the loading position. Ensure that no items
vulnerable to heat radiation are too close to the machine.
2.3 Electrical requirements
The Studio Plate Press should be connected to the mains supply,
(nominally 230V AC for the European Market or 110V AC for
America) by the mains cable provided and a suitable plug.
The press is designed for 230 volts AC 50/60 hertz and require
exclusive use of a power outlet rated for at least 10amps (Europe), OR
for 110 volts AC 5%, 15 amps (America).
Ensure that the supply rating on the machine specification plate
corresponds with your local supply and that the correct plug is fitted.
MAINS LEAD
The wires in this mains lead are coloured in accordance with the
following code:
Green and Yellow: EARTH
Blue: NEUTRAL
Brown: LIVE
As the colours of the wires in the mains lead of this apparatus may not

Page 5
Electrical requirements (cont.)
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:-
1. The wire coloured green and yellow must be connected to the
terminal in the plug that is marked by the letter E, or by the
safety earth symbol coloured green, or green and yellow.
2. The wire coloured blue must be connected to the terminal,
which is marked with the letter N, or coloured black.
3. The wire coloured brown must be connected to the terminal,
which is marked with the letter L, or coloured red.
NOTE:
Replacement of the mains cable must be done by a competent service
engineer.
HEATING ELEMENT
The heating element fitted to the Studio Plate Press is rated at 250
Watts.
Never connect to any outlet or power supply having a different
voltage/frequency from that on the machine data plate.
2.4 Adjusting the pressure
This press is fitted with a pressure-adjusting table, which enables the
table plate assembly to be raised or lowered.
a) To increase pressure or to use thinner materials turn table
anti-clockwise.
b) To decrease pressure or to lower the table plate assembly to
enable thicker materials to be used, turn the table clockwise.
NOTE
DO NOT adjust the pressure when the machine is clamped shut
CAUTION
Never increase the pressure to the extent of requiring undue force,
as this will place excessive stress on the press frame, resulting in
permanent damage to the press. If, on raising the handle, the
machine is lifted off the work surface then the clamping force is
excessive!
Please refer to page 11 showing the operation of the control unit.

Page 6
3. How to Operate the Studio
Plate Press
3.1 Starting with the Studio Plate Press
3.1.1 Plug into your supply outlet and switch supply on.
N.B. Please ensure the mains plug is easily accessible to the
operator so that in the event of a fault the machine can be
unplugged.
3.1.2 Turn on the Studio Plate Press; the on/off switch is on the
left bottom side of the machine. Set the machine controls as
necessary. See instructions for adjusting the pressure, 2.4 and
the operation of the time/temperature unit, Page 11. When the
set temperature is steady in the display the machine is ready to
use.
The head should be up when warming to operating
temperature.
3.2 Working with Heat Transfer Materials
Always ascertain from the supplier of material and transfer
paper, that the material to be used is suitable for, and has been
prepared for transfer printing.
3.2.1 Ensure that the heat setting and dwell time setting are correct
for the material being used.
3.2.2 Adjust the pressure setting of the machine by rotating the
table of the machine. (See exploded diagram in this manual)
clockwise for less pressure and anti-clockwise for more
pressure.
3.2.3 Place the article to be transfer printed/fused etc., onto the
pressing pad and locate the transfer paper/fusible material on
top of the article in position required.
3.2.4 Gently pull the toggle handle forward ensuring that the article
is firmly clamped between the heat plate and pressure pad.
3.2.5 When the pre-set dwell time has been reached, a buzzer will
sound. The heat plate should then be lifted by pushing the
handle back to its full extent.
Inhaltsverzeichnis
Andere Adkins Elektrowerkzeuge Handbücher

Adkins
Adkins Beta Swift Bedienungsanleitung

Adkins
Adkins STUDIO CLAM 38 Service-Handbuch

Adkins
Adkins Studio Large Format Clam Service-Handbuch

Adkins
Adkins Studio Versa Service-Handbuch

Adkins
Adkins OMEGA 750 Series Service-Handbuch

Adkins
Adkins Alpha Calender Roll-Master 1.2 Service-Handbuch

Adkins
Adkins STUDIO EZ AUTO CLAM Service-Handbuch

Adkins
Adkins Studio Clam Service-Handbuch

Adkins
Adkins Beta Maxi Service-Handbuch

Adkins
Adkins STUDIO CLAM 38 Service-Handbuch