AEMC Simple Logger L620 Bedienungsanleitung

SIMPLE LOGGER®
THERMOCOUPLE MODULE
L610
L620
L630
ENGLISH User Manual

Owner’s Record
The serial number for the Models L610, L620 and L630 is located on the
side of the case. Please record this number and purchase date for your
records.
SIMPLE LOGGER THERMOCOUPLE MODULE
MODEL #: _______________________________________________
SERIAL #: _______________________________________________
PURCHASE DATE: ________________________________________
DISTRIBUTOR: ___________________________________________

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols................................................2
1.2 Receiving Your Shipment..........................................................3
1.3 Ordering Information.................................................................3
1.3.1 Accessories and Replacement Parts............................3
2. PRODUCT FEATURES ...................................................................... 4
2.1 Indicators and Buttons ..............................................................4
2.2 Inputs and Outputs ...................................................................5
2.3 Mounting ...................................................................................5
3. SPECIFICATIONS............................................................................. 6
3.1 ElectricalSpecications ............................................................6
3.2 MechanicalSpecications ........................................................6
3.3 EnvironmentalSpecications....................................................7
3.4 SafetySpecications ................................................................7
4. OPERATION .................................................................................... 8
4.1 Software Installation .................................................................8
4.1 Recording Data.........................................................................9
4.3 Using the Software .................................................................10
5. MAINTENANCE ............................................................................. 11
5.1 Battery Installation ..................................................................11
5.2 Cleaning.................................................................................. 11
APPENDIX A ....................................................................................... 12
Importing .TXT Files into a Spreadsheet.........................................12
OpeningaSimpleLogger.TXTleinExcel ...........................12
Formatting the Date and Time ................................................13
Repair and Calibration...........................................................................15
Technical and Sales Assistance ............................................................15
Limited Warranty ...................................................................................16
Warranty Repairs...................................................................................16

2
Thermocouple Simple Logger®Models L610 / L620 / L630
CHAPTER 1
INTRODUCTION
Warning
These safety warnings are provided to ensure the safety of per-
sonnel and proper operation of the instrument.
• Read the instruction manual completely and follow all safety
information before operating this instrument.
• Use caution on any circuit: Potentially high voltages and cur-
rents may be present and may pose a shock hazard.
• Readthespecicationssectionpriortousingthedatalogger.
Neverexceedthemaximumvoltageratingsgiven.
• Safety is the responsibility of the operator.
• For maintenance, use only original replacement parts.
• NEVER open the back of the instrument while connected to
any circuit or input.
• ALWAYS connect the leads to the logger before inserting the
leads to the test voltage
• ALWAYS inspect the instrument and leads prior to use.
Replace any defective parts immediately.
• NEVER use the Simple Logger®Models L610, L620 and
L630 on electrical conductors rated above 30V in overvolt-
age category III (CAT III).
1.1 International Electrical Symbols
Thissymbolsigniesthattheinstrumentisprotectedbydoubleor
reinforcedinsulation.Useonlyspeciedreplacementpartswhen
servicing the instrument.
This symbol on the instrument indicates a WARNING and that
the operator must refer to the user manual for instructions before
operating the instrument. In this manual, the symbol preceding
instructions indicates that if the instructions are not followed, bodily
injury, installation/sample and product damage may result.
Risk of electric shock. The voltage at the parts marked with this
symbol may be dangerous.

Thermocouple Simple Logger®Models L610 / L620 / L630
3
1.2 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consistent
with the packing list. Notify your distributor of any missing items. If the equip-
mentappearstobedamaged,leaclaimimmediatelywiththecarrierand
notify your distributor at once, giving a detailed description of any damage.
Save the damaged packing container to substantiate your claim.
1.3 Ordering Information
Simple Logger®Thermocouple Model L610.................... Cat. #2116.15
(Type J)
Simple Logger®Thermocouple Model L620.................... Cat. #2116.16
(Type K)
Simple Logger®Thermocouple Model L630.................... Cat. #2116.17
(Type T)
All models are supplied with software (CD-ROM), 6 ft DB-9 RS-232 serial cable, 9V Alkaline
battery and user manual.
1.3.1 Accessories and Replacement Parts
One 6 ft RS-232 cable with DB9F ....................................... Cat. #2114.27
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com for availability

4
Thermocouple Simple Logger®Models L610 / L620 / L630
CHAPTER 2
PRODUCT FEATURES
2.1 Indicators and Buttons
The Simple Logger®has one button and one indicator. Both are located
on the front panel. The PRESS button is used to start and stop recordings
and to turn the logger on and off.
The Red LED indicates the status of the logger:
•Single Blink: STAND-BY mode
•Double Blink: RECORD mode
•Continuously On: OVERLOAD condition
•No Blinks: OFF mode
1
2
34
(1) Start/Stop Button
(2) Indicator Light
(3) Miniature T.C. Connecto
r
(4) RS-232 Interface
SIMPLE LOGGER
®
THERMOCOUPLE MODULE L620
®
INSTRUMENTS
30 V
CAT III
K
!RS-232
!INPUT
PRESS
LOGGER OPERATION:
1. Press to Start Logging
(Logging = Two Blinks)
2. Press to Stop Logging
(Stand-By = One Blink)
3. Press & Hold 5 sec. to Shut Off
(Off = No Blinks)
Warning: All Data will be Deleted!
!
Continuous LED indicates OUT OF RANGE

Thermocouple Simple Logger®Models L610 / L620 / L630
5
2.2 Inputs and Outputs
The left side of the Simple Logger®incorporates a color-coded miniature
T.C. connector that is compatible with the thermocouple for which your
logger was designed.
The right side of the logger has a female 9-pin “D” shell serial connector
used for data transmission from the logger to your computer.
2.3 Mounting
Your Simple Logger®is equipped with clearance holes in the base plate
tabs for mounting. For less permanent mounting, the Velcro®pads (sup-
plied loose) can be attached to the logger and the surface to which the
logger will be mounted.

6
Thermocouple Simple Logger®Models L610 / L620 / L630
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
Number of Channels: 1
Measurement Range: L610: 32° to 1380°F (0° to 750°C)
L620: -325°to 2280°F (-200°to 1250°C)
L630: -325°to 660°F (-200°to 350°C)
Input: L610: J Thermocouple
L620: K Thermocouple
L630: T Thermocouple
Input Connection: Miniature color-coded thermocouple jacks
Black- J, Yellow-K, Blue-T
Resolution: 12 Bit (better than 0.5°C)
Sample Rate: 4096/hrmax;decreasesby50%eachtimememoryisfull
Data Storage: 16,384 readings
Data Storage Technique: TXR™TimeExtensionRecording™
Power: 9V Alkaline NEDA 1604, 6LF22, 6LR61
Battery Life Recording: Up to 1 year of recording @ 77°F (25°C)
Output: RS-232 via DB9 connector (4800 Baud)
Reference condition: 23°C ± 3K, 20 to 70% RH, Frequency 50/60Hz, No AC external mag-
netic eld, DC magnetic eld ≤ 40A/m, battery voltage 9V ± 10%.
Accuracy: ±0.5% of Reading + 1°C + T/C Accuracy
3.2 Mechanical Specifications
Size: 2-7/8x2-5/16x1-5/8"(73x59x41mm)
Weight (with battery): 5 oz (140g)
Mounting: Base plate mounting holes or Velcro®pads
Case Material: Polystyrene UL V0

Thermocouple Simple Logger®Models L610 / L620 / L630
7
3.3 Environmental Specifications
Operating Temperature: -4 to 158°F (-20 to 70°C)
Storage Temperature: -4 to 176°F (-20 to 80°C)
Relative Humidity: 5to95%non-condensing
Temperature Inuence: 0.1%/°Coverfulltemperaturerange
3.4 Safety Specifications
Working Voltage: EN 61010, 30V, Cat III
*All specications are subject to change without notice

8
Thermocouple Simple Logger®Models L610 / L620 / L630
CHAPTER 4
OPERATION
4.1 Software Installation
Minimum Computer Requirements
• Windows®7, 8, 8.1, 10
• Processor - 486 or higher
• 8MB of RAM
•8MBofharddiskspaceforapplication,400Kforeachstoredle
•One9-pinserialport;oneparallelportforprintersupport
• CD-ROM drive
1. Insert the Simple Logger®CD into your CD-ROM drive.
If auto-run is enabled, the Setup program will start automatically. If
auto-run is not enabled, select Run from the Start menu and type in
D:\SETUP (if your CD-ROM drive is drive D. If this is not the case,
substitute the appropriate drive letter).
2. The Set-up window will appear.
Figure 1
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere AEMC Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung