AEMC 1005 Bedienungsanleitung

MEGOHMMETER 1005
1015
ENGLISH User Manual
AEMC
INSTRUMENTS
MEGOHMMETER
MODEL 1005
Battery
Check
OFF MΩ- 500 V
10 Ω +
10 Ω −
0
.
1
0
.
5
1
5
1
0
5
0
1
0
0
5
0
0
1
0
0
0
0
1
2
3
4
5
6
7
8
9
1
0
0
1
0
0
2
0
0
3
0
0
4
0
0
5
0
0
6
0
0
V
600V
-
+
6
!
MΩ
OFF
MΩ- 1000 V
MΩ- 500 V
1000 Ω
AEMC
INSTRUMENTS
MEGOHMMETER
MODEL 1015
Battery
Check
10 Ω +
10 Ω −
0
.
1
0
.
5
1
5
1
0
5
0
1
0
0
5
0
0
1
0
0
0
0
1
2
3
4
5
6
7
8
9
1
0
0
1
0
0
2
0
0
3
0
0
4
0
0
5
0
0
6
0
0
V
600V
-
+
6
!
MΩ
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 1402.01 / 1403.01
Model #: 1005 / 1015
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

Table of Contents
1. INTRODUCTION............................................................................... 2
1.1 International Electrical Symbols................................................2
1.2 DenitionofMeasurementCategories .....................................3
1.3 ReceivingYourShipment..........................................................3
1.4 OrderingInformation.................................................................3
1.4.1 AccessoriesandReplacementParts............................3
2. PRODUCT FEATURES ...................................................................... 4
2.1 Description................................................................................4
2.2 Features....................................................................................4
2.3 Model1005ControlFeatures ...................................................5
2.4 Model1015ControlFeatures ...................................................6
3. SPECIFICATIONS............................................................................. 7
3.1 ElectricalSpecications ............................................................7
3.2 GeneralSpecications..............................................................8
3.3 SafetySpecications ................................................................8
4. OPERATION .................................................................................... 9
4.1 SafetyCheck(VoltageTest) .....................................................9
4.2 InsulationResistanceTesting(MΩRange) ..............................9
4.2.1 TestVoltage ..................................................................9
4.2.2 SpotTesting ................................................................10
4.2.3 RatioTesting ...............................................................10
4.2.4
TipsForSuccessfulInsulationResistanceTesting ......... 11
4.2.5 InsulationMeasurement-Connections ...................... 11
4.2.6 InsulationResistanceMeasurementsonMotors........14
4.3 Continuity Measurements .......................................................15
4.4 ResistanceMeasurements(Model1015Only)......................15
5. MAINTENANCE ............................................................................. 16
5.1 Maintenance ...........................................................................16
5.1.1 Battery Test .................................................................16
5.1.2 BatteryandFuseReplacement ..................................17
5.1.3 Cleaning......................................................................17
RepairandCalibration...........................................................................18
TechnicalandSalesAssistance ............................................................18
Limited Warranty ...................................................................................19
WarrantyRepairs...................................................................................19
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

2
Megohmmeter Models 1005 and 1015
CHAPTER 1
INTRODUCTION
WARNING
Thesesafetywarningsareprovidedtoensurethesafetyofpersonnel
andproperoperationoftheinstrument.
• Readthisinstructionmanualcompletelyandfollowallthesafetyinfor-
mationbeforeattemptingtouseorservicethisinstrument.
• Safetyistheresponsibilityoftheoperator!
• Testsaretobecarriedoutonlyondeadcircuits!Checkforlivecircuits
beforemakingresistancemeasurements(safetycheck).
• Alwaysmakeconnectionsfromtheinstrumenttothecircuitundertest.
• Thesemegohmmetersare sourcesofhighvoltage,asisthesample
connectedtothem.Allpersonsperformingorassistinginthetestsmust
followallsafetyprecautionstopreventelectricalshocktothemselves
andtoothers.
• AEMC considers the use of rubber gloves to be an excellent safety
practice even if the equipment is properly operated and correctly
grounded.
• When testing capacitance samples, make sure that they have been
properlydischargedandthattheyaresafetotouch.Dielectricinsula-
tionsamplesshouldbeshort-circuitedforatleastvetimestheamount
oftimetheywereenergized.
• Neveropenthebackoftheinstrumentwhileconnectedtoanycircuitor
input.
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or rein-
forced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
In conformity with WEEE 2002/96/EC
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

Megohmmeter Models 1005 and 1015
3
1.2 Definition of Measurement Categories
Cat. I: Formeasurements on circuits not directly connected to theAC
supply wall outlet such as protected secondaries, signal level,
andlimitedenergycircuits.
Cat. II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
Cat. III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installationandcircuitbreakers.
Cat. IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceiving your shipment, makesure that the contentsareconsis-
tentwith the packing list.Notify your distributor ofany missing items. If
theequipmentappearstobedamaged,leaclaimimmediatelywiththe
carrierandnotifyyourdistributoratonce,givingadetaileddescriptionof
anydamage.Savethedamagedpackingcontainertosubstantiateyour
claim.
1.4 Ordering Information
MegohmmeterModel1005..................................................Cat. #1402.01
MegohmmeterModel1015..................................................Cat. #1403.01
Both include a carrying case, shockproof rubber housing, set of black and red leads, black
test probe, red alligator clip, spare fuse (inside megohmmeter), 4 x 1.5V alkaline “AA” bat-
teries (not installed), and a user manual.
1.4.1 Accessories and Replacement Parts
Setofreplacementleads..................................................... Cat. #2118.41
CarryingCase...................................................................... Cat. #2118.40
Fuses,setof5,1.6A............................................................Cat. #2970.22
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com for availability
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

4
Megohmmeter Models 1005 and 1015
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheMegohmmeters,Model1005and1015,areanaloginstrumentswith
foureasy-to-readscales.
TheMΩscaleisaneasy-to-readlogscalegraduatedfrom0.1to1000MΩ
(yellow background) at 500V and 1000V (Model 1015). The Ωscale is
linearwitharangefrom0to10Ω(whitebackground).
Tousethe0to1000ΩscaleontheModel1015,takethereadingonthe
0 to 10Ωrangeandmultiplythereadingby100.TheACvoltagescaleis
linearwitharangeof0to600VAC(whitebackground).Continuitytestsare
donewithatestcurrentof200mA.
Thecoloredbatteryscalehasarangeofgreenforagoodbatteryanda
rangeofredorlowerforadefectivebattery.
A built-in battery tester is provided by simply pressing the yellow push
buttonwhentheselectorswitchisintheOFFposition.
Voltmeter(safetycheck)witharangeof0to600VACisstandardandworks
when the selector switch is in the 500V position or the 1000V position
(Model1015only).
2.2 Features
• Measuresinsulationat500V(Model1005)
• Pushbuttonforbatterycheck
• Designed for harsh environments: offshore, mining, heavy-duty
eld,industrial,commercialelectricalandmilitaryuse
• 0to10Ω+ and 0 to 10Ω-continuityranges
• Continuity200mAtestcurrent
• Smallandlightweight
• Large,direct-reading,coloredscale
• 600Vtestvoltagerange(safetycheck)
• Yellownon-slipshockproofcase
• Measuresinsulationat1000V(Model1015Only)
• 0to1000Ωresistancerange(Model1015Only)
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

Megohmmeter Models 1005 and 1015
5
2.3 Model 1005 Control Features
–
1 2
3
4
5
6
7
Figure 1
1. Line(–)terminal
2. Earth/Ground(+)terminal
3. Mechanicalzeroadjustmentscrews
4. 4-positionrotaryswitch
5. Protectiverubberhousing
6. Push-to-testbutton
7. Batterycheckandindicationdisplay
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

6
Megohmmeter Models 1005 and 1015
2.4 Model 1015 Control Features
–
1 2
3
4
5
6
7
Figure 2
1. Line(–)terminal
2. Earth/Ground(+)terminal
3. Mechanicalzeroadjustmentscrews
4. 4-positionrotaryswitch
5. Protectiverubberhousing
6. Push-to-testbutton
7. Batterycheckandindicationdisplay
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

Megohmmeter Models 1005 and 1015
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
INSULATION TESTS
DC Test Voltage:500V(Model1005)
500Vand1000 V(Model1015)
Megohm Range: 0.1 to 1000MΩ
Short Circuit Current: ≤6mA
Accuracy: ±5%ofreading
Discharging Time (Auto): 1s/µF
CONTINUITY TESTS
Range: 0 to 10Ω- ;0to10Ω+
Short Circuit Current: ≥200mA
Open Circuit Voltage: 4.5to6.5V
Accuracy: ±3%fullscale
RESISTANCE TESTS (Model 1015 Only)
Range: 0 to 1000Ω
Short Circuit Current: ≥2mA
Open Circuit Voltage: 4.5to6.5V
Accuracy: ±3%fullscale
VOLTAGE TESTS (Safety Check)
Voltage Range: 0to600VAC
Frequency: 45to400Hz
Accuracy:3%offullscale
Input Impedance:300kΩ
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com

8
Megohmmeter Models 1005 and 1015
3.2 General Specifications
Power Supply: 4 x 1.5VAAbatteries
Dielectric Test:6000V,50/60 Hz,1minute
Meter Movement: Ruggedtautbandsuspension
Dimensions: 6.6x4.2x2.2"(167x106x55mm)
Weight:1.45lbs(650 g)
Operating Temperature Range:
14°to131°F(-10°to55°C),20-80%RH
Storage Range:-40°to158°F(-40°to70°C),10-90%RH
Terminals: “-”Line(black);“+”earth(red);accepts4mmbananaplugs
Reference Conditions: 63° to 73°F (17° to 23°C), 45-55% RH; Supply Voltage: 5.3 to 5.7V;
Voltage Frequency: 45 to 65Hz; Electric Field: <1V/M; Magnetic Field: <40A/M; Position:
Horizontal ± 5°.
3.3 Safety Specifications
IEC 1010-1: Safety requirements for electrical equipment for measure-
ment,controlandlaboratoryuse
VDE 0413-1:Insulationtesters
VDE 0413-4: Ohmmeters
VDE 0100:Specicationsforthecreationofhighcurrentinstallationsof
nominalvoltagelessthan1000V
IEC 801: Electromagnetic compatibility for measurement and control
equipmentinindustrialprocesses
Part2:Sectionsrelatingtoelectrostaticdischarges
Part3:Sectionsrelatingtoradiatedelectricelds
Part4:Sectionsrelatingtoelectrostaticdischarges
Part5:Sectionsrelatingtoelectricshocks
IEC 68.2.6: Vibrations
IEC 68.2.27:Shocks
IEC 68.2.29:Shakes
IEC 68.2.31:Bumps
IEC 68.2.32:Freefall
UL 94: Self-extinguishingcapability
Specications are subject to change at any time without notice
www.GlobalTestSupply.com
Quality AEMC Products Online at: sales@GlobalTestSupply.com
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Meter Handbücher anderer Marken

PCB Piezotronics
PCB Piezotronics 3711E1110G Bedienungsanleitung

Schmidt
Schmidt ZF2 Bedienungsanleitung

Rae
Rae ToxiRAE Pro CO2 Bedienungsanleitung

HP
HP 4338A Bedienungsanleitung

Lutron Electronics
Lutron Electronics PM-9102 Bedienungsanleitung

Lutron Electronics
Lutron Electronics HT-3015 Bedienungsanleitung