Agilent Technologies G2545A Technisches Dokument

Agilent Technologies
Agilent G2545A
Hybridization Oven
Installation, Operation, and
Maintenance Guide

2HybridizationOvenInstallation, Operation, and Maintenance
Notices
© Agilent Technologies, Inc. 2004 - 2010
No part of this manual may be reproduced in
any form or by any means (including elec-
tronic storage and retrieval or translation
into a foreign language) without prior agree-
ment and written consent from Agilent
Technologies, Inc. as governed by United
States and international copyright laws.
Manual Part Number
G2545-90001
Edition
Fourth Edition, January 2010
Printed in USA
Agilent Technologies, Inc.
5301 Stevens Creek Blvd.
Santa Clara, CA 95051
Warranty
The material contained in this
document is provided “as is,” and
is subject to being changed,
without notice, in future editions.
Further, to the maximum extent
permitted by applicable law,
Agilent disclaims all warranties,
either express or implied, with
regard to this manual and any
information contained herein,
including but not limited to the
implied warranties of merchant-
ability and fitness for a particular
purpose. Agilent shall not be
liable for errors or for incidental
or consequential damages in
connection with the furnishing,
use, or performance of this docu-
ment or of any information
contained herein. Should Agilent
and the user have a separate
written agreement with warranty
terms covering the material in this
document that conflict with these
terms, the warranty terms in the
separate agreement shall control.
Technology Licenses
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in accor-
dance with the terms of such license.
Restricted Rights Legend
U.S. Government Restricted Rights. Soft-
ware and technical data rights granted to
the federal government include only those
rights customarily provided to end user cus-
tomers. Agilent provides this customary
commercial license in Software and techni-
cal data pursuant to FAR 12.211 (Technical
Data) and 12.212 (Computer Software) and,
for the Department of Defense, DFARS
252.227-7015 (Technical Data - Commercial
Items) and DFARS 227.7202-3 (Rights in
Commercial Computer Software or Com-
puter Software Documentation).
Safety Notices
CAUTION
A CAUTION notice denotes a haz-
ard. It calls attention to an operat-
ing procedure, practice, or the like
that, if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and
met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly per-
formed or adhered to, could result
in personal injury or death. Do not
proceed beyond a WARNING
notice until the indicated condi-
tions are fully understood and
met.

Hybridization Oven Installation, Operation, and Maintenance 3
Content
1 Safety and Regulatory Information 5
Intended Use 6
Important Safety Warnings 6
Safety and Regulatory Certifications 7
Technical and Environmental Specifications 8
Symbols 9
Fuses and Battery 9
Cleaning 9
Recycling the Product 9
2 Installation 11
Step 1. Prepare the site 12
Step 2. Inspect the shipment 13
Step 3. Unpack and set on the bench 15
Step 4. Install the Oven 16
3Operation19
Control Panel Interface 20
Operating the Hybridization Oven 22
To set a temperature 22
To load or unload the hybridization chamber 22
To calibrate the oven 24

5
Hybridization Oven
Installation, Operation, and Maintenance
Agilent Technologies
1
Safety and Regulatory Information
Intended Use 6
Important Safety Warnings 6
Safety and Regulatory Certifications 7
European Declaration of Conformity 7
Canadian EMC Statement 7
Sound Emission Certification for Federal Republic of Germany 8
Technical and Environmental Specifications 8
Symbols 9
Fuses and Battery 9
Cleaning 9
Recycling the Product 9
This chapter provides important safety and regulatory information about
the Agilent G2545A Hybridization Oven.

1 Safety and Regulatory Information
6HybridizationOvenInstallation, Operation, and Maintenance
Intended Use
This unit is for professional, industrial, or educational use, where the
preparation or testing of materials is done at approximately atmospheric
pressure and no flammable, volatile, or combustible materials are being
heated. This unit is not intended for hazardous or household use.
Important Safety Warnings
There are several important safety notices that you must always keep in
mind when you use the Hybridization Oven.
Many internal parts of the instrument carry dangerous voltages
If the oven is connected to a power source, even if the power switch is
off, potentially dangerous voltages exist on:
•the wiring between the oven power cord and the AC power supply
•the AC power supply itself
•the wiring from the AC power supply to the power switch
With the power switch on, potentially dangerous voltages also exist on:
•all electronics boards in the oven
•the internal wires and cables connected to these boards
WARNING
All these parts are shielded by covers. With the covers in place, it should be difficult
to accidentally make contact with dangerous voltages. Unless specifically
instructed to, never remove a cover.
WARNING
If the power cord insulation is frayed or worn, the cord must be replaced. Contact
your Agilent service representative.

Safety and Regulatory Information 1
Hybridization Oven Installation, Operation, and Maintenance 7
Safety and Regulatory Certifications
European Declaration of Conformity
Canadian EMC Statement
ICES/NMB- 001:2004
This ISM device complies with Canadian ICES- 001.
Cet appareil ISM est conforme a la norme NMB—001 du Canada.
Manufacturer's Name: Sheldon Manufacturing, Inc.
Manufacturer's Address: 300 N. 26th Avenue
Cornelius, OR 97113, USA
Declares that the product as originally delivered:
Product Name: Hybridization Oven
Part Number: 1013AG, 1013AG-2
(as Agilent model G2545A)
complies with the essential requirements of the following applicable European Directives, and
carries the CE marking accordingly:
•The Low Voltage Directive 2006/95/EC
•The EMC Directive 2004/108/EC
DECLARATION OF CONFORMITY
According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014

1 Safety and Regulatory Information
8HybridizationOvenInstallation, Operation, and Maintenance
Sound Emission Certification for Federal Republic of Germany
Sound pressure LpA < 70 dB at operator and bystander positions, normal
operation, according to EN27779 (Type Test). This statement is given to
comply with the requirements of the German Sound Emission Directive,
from 18 January 1991.
Technical and Environmental Specifications
Below are the oven’s technical and environmental specifications.
•Class 1 equipment
•Pollution degree 2
•Installation Category II
•Indoor use only in ordinary atmospheres
•Operating ambient temperatures between 15 °C and 35 °C
•Relative humidity between 15 % to 85 %
•Altitude not to exceed 2000 m operating
•G2545A is rated for mains connection to 100–120 VAC or 220–240 VAC,
50/60 Hz, 6A, with main supply voltage fluctuations up to ±10% of the
nominal voltage
Below are the unit specificiations:
Net weight Unloaded unit weight, without rotator: 34.0 kg
(75.0 lbs)
Interior dimensions 31.8 cm x 30.5 cm x 36.8 cm
(12.5 in wide x 12 in deep x 14.5 in high)
Temperature Operating temperature range: Amb. +5 °C to 70 °C
Precision: 0.1 °C
Rotation Speed 8.94 meters/sec (20 mph)

Safety and Regulatory Information 1
Hybridization Oven Installation, Operation, and Maintenance 9
Symbols
Warnings in the manual or on the oven must be observed during all
phases of operation, service, and repair of this oven. Failure to comply
with these precautions violates safety standards of design and the
intended use of the oven. Agilent Technologies assumes no liability for the
customer’s failure to comply with these requirements.
Fuses and Battery
The oven uses one 5 × 20 mm fuse, 6.3 A, 250 V, type T. This fuse is
located at the rear of the oven, above the power cord receptacle.
Cleaning
See “Cleaning” on page 26.
Recycling the Product
For recycling, contact your local Agilent sales office.
See accompanying instructions for further description or discussion of
a control or user item.
Indicates a hot surface.
Indicates earth (ground) terminal.
Indicates potential shock hazard behind this partition.

1 Safety and Regulatory Information
10 Hybridization Oven Installation, Operation, and Maintenance
Andere Handbücher für G2545A
1
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Agilent Technologies Ofen Handbücher



















