Airspan AS4000 Leitfaden

605-0000-452 Issue 1.3dr Date 7/02/00
AS4000
Wireless Local Loop System
Demand Assignment
Central Terminal
Installation and Commissioning

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 2of 8
This Page Intentionally Blank

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 3of 8
Notice
1. This manual is subject to revision.
2. All rights reserved.
3. Right of modification reserved.
4. This manual is supplied without liability for errors or omissions.
5. No part of this manual may be reproduced or used except as authorised by contract or
other written permission.
6. This equipment is conditioned by the requirement that no modifications will be made to
the equipment unless the changes or modifications are expressly approved by ACC
Communications
7. Prerequisite skills: Personnel installing, commissioning, and maintaining the Airspan
products must have a basic knowledge of telephony and radio communications, and
have experience in installing, commissioning and maintaining telecommunications
products. ACC provides a range of comprehensive training courses specifically aimed
at providing operators/users of Airspan products with the prerequisite skills to install,
commission and or maintain the product. The courses can be tailored to provide the
level of training required by the operator/user.
8. Airspanand Sitespanare Registered Trademarks of Airspan Communications
Corporation.
For additional information on Airspan Systems, please call your ACC Representative, or
contact ACC at: Cambridge House
Oxford Road
Uxbridge
Middlesex
UB8 1UN
Call (44) 1784 886700

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 4of 8
This Page Intentionally Blank

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 5of 8
Safety Instructions - Warnings and Cautions
SAFETY
1. Read and follow all warning notices and instructions marked on the product or included in
this manual
2. Do not allow anything to rest on any power cord and do not locate the product where
persons could step or walk on a power cord.
3. When installed in the final configuration, the product must comply with the applicable Safety
Standards and regulatory requirements of the country in which it is installed. If necessary,
consult with the appropriate regulatory agencies and inspection authorities to ensure
compliance.
4. No hazardous RF radiation is emitted from the equipment. Measured at the surface of
the CRU radome, when transmitting, the maximum total power radiated from the CRU is
0.01% of the UK National Radiological Protection Board basic restriction per kg. of body
part.
WARNING - HAZARDOUS VOLTAGES
On AC installations, hazardous voltages exist. Use caution when verifying or working with
AC power. Remove metal jewellery that could come into contact with AC power.
On DC sections, short circuiting the low voltage, low impedance circuits can cause severe
arcing that may result in burns or eye damage. Remove rings, watches etc. to avoid shorting
DC circuits.
Electro-Static Discharge ESD
Electro-Static Discharge. Many circuits contain devices which are susceptible to damage from
high impedance voltage sources. To avoid such risks always follow anti-static procedures
where marked.

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 6of 8
NOTE
Airspan products do not contain hazardous substances (as defined in UK ‘Control of
Substances Hazardous to Health Regulations 1989’, and the ‘Dangerous Substances
Regulations 1990’). At the end of any Airspan product’s life cycle, the customer should
consult with DSC to ensure that the product is disposed of in conformance with the relevant
regulatory requirements
The Symbol on an Airspan product signifies that it has been certified according to the EMC
directive 89/336/EEC. The product fulfils the requirements according to the following
standards:
EN50082-1 for Immunity.
EN55022 Group 1 Class A for the Central Terminal Emissions.
EN55022 Group 1 Class B for the Subscriber Terminal Emissions.
NOTE
The Subscriber Terminal equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.
CAUTION PA INSERTION
Care should be taken when installing PAs to ensure that the card connector mates with the
backplane connector correctly. Any attempt to ram the card home or force the
card into he slot may cause damage to the connector. Insert the card until the connectors
engage, ease the card into the backplane until fully engaged. Lock top and bottom with a
screwdriver. If resistance is met remove the card and reinsert. If difficulty persists contact the
Airspan service centre.
CAUTION DIP/LNA INSERTION
Care should be taken when installing DIP/LNAs to ensure that the card connector mates with
the backplane connector correctly. Any attempt to ram the card home or force the
card into he slot may cause damage to the connector. The board extractor levers mat be used
to assist with insertion, when the card is home press the body of the DIP/LNA to ensure that
the connector is fully engaged. If resistance is met remove the card and reinsert. If difficulty
persists contact the Airspan service centre

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 7of 8
User Response Form
Mail: Airspan Communications Limited Fax: (44) 01895-467182
Cambridge House
Oxford Road
Uxbridge
Middlesex
UB8 1UN
Document Rating Excellent Good Average Below Average Poor
Accuracy / Completeness qqqqq
Clarity / Organisation qqqqq
Figures qqqqq
Table of Contents/Index qqqqq
The nature of this response is Addition qDeletion qCorrection q
Please enter details of response below (include precise reference to Section, Page, Paragraph)
Please Complete the following for acknowledgement/response:
Name: ........................................ Address ..........................................
Company ........................................ ..........................................
Job Title ........................................ ..........................................
Department ........................................ ..........................................
Telephone ........................................ ..........................................
Thank you for your co-operation and assistance.

AS4000 Central Terminal
Installation and Commissioning Preface
605-0000-452
Issue 1.3dr Date 7/02/00
Page 8of 8
This Page Intentionally Blank

AS4000 Central Terminal
Installation and Commissioning ICL 001
605-0000-452
Issue 1.3dr Date 7/02/00
Page 1of 2 © Copyright Airspan Communications Corporation 2000
ISSUE CONTROL LIST
Title Issue Date Issue Details
Title Page 1.3dr February 2000
ICL-001 1.3dr February 2000
IXL-001 1.3dr February 2000
GSI-001 1.3dr February 2000
GSI-002 1.3dr February 2000
GSI-003 1.3dr February 2000
DLP-001 1.3dr February 2000
DLP-002 1.3dr February 2000
DLP-003 1.3dr February 2000
DLP-004 1.3dr February 2000
DLP-005 1.3dr February 2000
DLP-006 1.3dr February 2000
DLP-007 1.3dr February 2000
DLP-008 1.3dr February 2000
DLP-009 1.3dr February 2000
DLP-010 1.3dr February 2000
DLP-011 1.3dr February 2000
DLP-012 1.3dr February 2000
DLP-013 1.3dr February 2000
DLP-014 1.3dr February 2000
DLP-015 1.3dr February 2000
DLP-016 1.3dr February 2000
DLP-017 1.3dr February 2000
Appendix 1 1.3dr February 2000
Appendix 2 1.3dr February 2000
Appendix 3 1.3dr February 2000
Appendix 4 1.3dr February 2000
1.3dr February 2000

AS4000 Central Terminal
Installation and Commissioning ICL 001
605-0000-452
Issue 1.3dr Date 7/02/00
Page 2of 2
CHANGE TYPE/DATE PURPOSE PAGES AFFECTED
Issue #, Month Year
1.0 Initial Document All
1.1 April 99 Commissioning details
added DLPs6-17 and Appendix’s
1.2 August 99 Update to
commissioning for
Sitespan 3.4
DLPs 6-14
1.3 December 99 Modification to
commissioning process DLPs 6-12
Andere Handbücher für AS4000
6
Inhaltsverzeichnis
Beliebte Touch-Terminal Handbücher anderer Marken

Wincor Nixdorf
Wincor Nixdorf iPOS plus Advanced Bedienungsanleitung

Ingenico
Ingenico AXIUM EX4000 Bedienungsanleitung

Heisei Electronics
Heisei Electronics Q-POS 815 Bedienungsanleitung

Amano
Amano MTX-15 Bedienungsanleitung

FLOWBIRD
FLOWBIRD CWT Compact Touch Bedienungsanleitung

Demco
Demco SP7 Bedienungsanleitung

Motorola
Motorola MTP850 Bedienungsanleitung

YASKAWA
YASKAWA 62H-MDC0 Bedienungsanleitung

MVG industries
MVG industries NeptuLink Bedienungsanleitung

Price Industries Limited
Price Industries Limited FDC Gebrauchsanweisung

Honeywell
Honeywell TemaKey Bedienungsanleitung

EBN
EBN BPC65-B-A16G Bedienungsanleitung