Airthereal EVENING TIDE Bedienungsanleitung

USER MANUAL
READ AND SAVE THESE INSTRUCTIONS
EVENING TIDE EVT-18K
18KW ELECTRIC TANKLESS
WATER HEATER
EVT-18KEvening Tide

1
CONTENTS
2
2
5
6
8
15
16
18
INTRODUCTION
COMPONENTS
SPECIFICATIONS
IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION GUIDELINE
CONTROLS
TROUBLESHOOTING
LIMITED WARRANTY

COMPONENTS
Front Cover
Cable Entry
Control Key
Cold Water Inlet
LED Display
Hot Water Outlet
2
INTRODUCTION
Congratulations on your purchase and welcome to Airthereal!
To fully benefit from the support that Airthereal offers please register at www.airthereal.com/register
EVT-18KEvening Tide
OUTWARD

3
TEMP Sensor
Thermostat
Heating Element
Triac
Transformer
Connection Plug
To Display
Water Flow Meter
PRODUCT INNER STRUCTURE

4
ELECTRICAL DIAGRAM
CONNECTION
DISP: Connection plug to display
FLOW: Connection plug to the flow sensor
IN: Connection plug to the input temperature sensor
OUT: Connection plug to the output temperature sensor
SCR1
POWER IN SCR2 ISP
LEAKAGE DISP
OUT FLOW
IN
Overheat
L1
L1'
L2
L2'

SPECIFICATIONS
5
Remarks:
The above wire size and circuit breaker size are for this EVT-18K unit only. If you need other high-
power appliances, please do further research for that.
EVT-18K
240 V
18 kW
2 x 40 AMP
75 A
2X (8AWG/2)
0.475 GPM / 1.8L/min
7.25 PSI - 108.78 PSI
3/4" NPT
Wall Mounted
Digital Panel
17.25'' x 12.22'' x 3.43''
16.53 Lbs
Model
Voltage
Power
Min. Required Circuit Breaker Size
Max. Amperage
Recommended Wire Size
Min. Water Flow to Activate the Unit
Safe Operating Pressure
Water Connections
Installation
Temperature Setting
Dimensions (LxWxH)
Weight
SIZING GUIDE
Please use the chart below to see how many gallons per minute your tankless water heater can
produce with your incoming water temperature. The gallons per minute is calculated assuming
108°F outlet temperature.
Inlet Temp (°F)
41
50
59
68
77
Model
EVT-18K
GPM
1.7
2.0
2.4
2.9
3.8
Suggested Usage
Kitchen Faucet
Shower
Shower
Shower
Shower
Outlet Temperature (°F)
108

IMPORTANT SAFETY INSTRUCTIONS
6
WARNING:
When installing or using any high voltage electrical appliance basic safety precautions should always
be followed. Under no circumstance should you attempt to clean, install, inspect, repair, disassemble,
or otherwise service this water heater without first shutting off all power to the unit directly at the
circuit breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE
THIS WARNING.
THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED
PLUMBER IN ACCORDANCE WITH ALL NATIONAL, STATE, PROVINCIAL AND LOCAL
ELECTRICAL & PLUMBING CODES. PLEASE READ THESE INSTRUCTIONS THOROUGHLY
AND COMPLETELY PRIOR TO INSTALLATION & USE. FAILURE TO DO SO COULD CAUSE
PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH. This manual should be given to the
homeowner after installation and should be retained for future reference.
GENERAL SAFETY
1. Risk of Fire - DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance. Keep rags and other combustibles away.
2. FOR HOUSEHOLD, INDOOR USE ONLY.
3. Risk of electric shock, CONNECT ONLY TO A CIRCUIT THAT ISPROTECTED BY
A GROUND-FAULT CIRCUIT INTERRUPTER (GFCI).
4. This appliance MUST be permanently connected to the fixed double pole circuit breaker and the
appliance must be installed vertically. DO NOT install this appliance near tinder or a strong
magnetic field place.
5. If there is damage to a wire, you must contact a qualified electrician to replace it.
6. The minimum environmental temperature for safe storage and operation of the water heater must
be above 33°F, if not, may cause water heater damage and dangerous conditions.
7. This appliance is forbidden to be switched on if you think it might be frozen, as this could result
in serious damage to the unit. Wait until you are sure that it has completely thawed out before
you switch it on.
8. DO NOT install this hot water unit in a location where it may be subject to freezing temperatures.
IF YOU IGNORE THIS WARNING, THE UNIT MAY GET PERMANENT DAMAGE DUE TO
INTERNAL COMPONENTS FREEZING.

7
Time To Produce a Serious Burn
More than 5 minutes
1 1/2 to 2 minutes
About 30 seconds
About 10 seconds
Less than 5 seconds
Less than 3 seconds
About 1 1/2 seconds
About 1 second
Temperature
120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F
Water temperature over
125°F can cause severe
burns instantly or death
from scalds.
Children, disabled and
elderly are at highest risk
of being scalded.
See instruction manual
before setting temperature
at water heater.
Feel water before bathing
or showering. Temperature
limiting values are available,
see manual.
If the hot water unit has
been paused during use,
you may initially get a short
burst of very hot water when
you turn it on again. Please
run water through for a few
seconds to settle down the
water temperature.
Water Temperature Safety
Safety and energy conservation are factors to be considered
when selecting the water temperature setting of the water
heater's thermostat. Water temperatures above 125°F can
cause severe burns or death from scalding. Be sure to read
and follow the warnings outlined on the label pictured below.
The chart shown below may be used as a guide in determining
the proper water temperature for your home to prevent burns.
Time/Temperature Relationship in Scalds
DANGER: Households with small children, any disabled
person, or elderly persons may require a 120°F or lower
thermostat setting to prevent contact with overly "HOT"
water. The temperature of the water in the heater is
regulated by the electronic control on the front of the
water heater.
Notice: Mixing valves are recommended for reducing point
of use water temperature by mixing hot and cold water in
branch water lines. It is recommended that a mixing valve
complying with the Standard for Temperature Actuated
Mixing Valves for Hot Water Distribution Systems be installed.

8
INSTALLATION GUIDELINE
MOUNTING
Step 1
Step 2
1. Locate the installation position for the water heater.
2. Place the bracket on the wall and use a pencil to mark the screw hole locations. Make sure the
outlet and inlet are pointed downward vertically.
Drill four 0.24”(6mm) diameter holes on the wall. Insert the plastic anchors into the holes.
11.69 inch
Hole
Plastic Anchor
Drill

9
Step 3
Step 4
Hang the water heater onto the bracket with the outlet and inlet pointed downward.
Make sure the water heater is secure before continuing.
Place the bracket onto the wall and drill mounting screws directly into the plastic anchors to secure
the bracket.
Bracket
ST 4.2*30mm
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Heizung Handbücher anderer Marken

Empire Heating Systems
Empire Heating Systems WCC65 Bedienungsanleitung

Wetekom
Wetekom 92 86 43 Bedienungsanleitung

Desa
Desa SPC170-F Bedienungsanleitung

Watlow
Watlow Watrod Electric Tubular Heaters Bedienungsanleitung

Haverland
Haverland ECO-DRY GPS Series Stücklistenhandbuch

Stelpro
Stelpro ASILVC2060 Series Bedienungsanleitung