Alean AL-238P Bedienungsanleitung

AL-238
PPROGRAMMING GUIDE
AL-238P
Installation Manual

AL-238
PPROGRAMMING GUIDE
2
Contents
Part 1 General description ................................................................................................................................................................... 3
1. AL-238P main function ............................................................................................................................................................ 3
2.System wiring instructions ....................................................................................................................................................... 5
3. Main board LED lights status description ............................................................................................................................... 8
4.Main parts description .............................................................................................................................................................. 9
Part 2 System Operation Instruction .................................................................................................................................................. 11
1.User operation guide.............................................................................................................................................................. 11
2.System programming instruction ........................................................................................................................................... 12
3. Control panel programming list and each item default value ................................................................................................ 12
Attachment 1 ............................................................................................................................................................................. 12
Attachment 2 ............................................................................................................................................................................. 13
4. Programming example .......................................................................................................................................................... 23
Part 3.Zone type and password permission description .................................................................................................................... 25
1. Zone type and description .................................................................................................................................................... 25
2. System password permission description ............................................................................................................................. 26
Part 4. Expansion module function application .................................................................................................................................. 26
1. The 4G module uploads the network alarm center, only 1 center can be uploaded ............................................................. 26
2. The IP module is uploaded to the network alarm center, and the IP can be uploaded to 2 centers at the same time ......... 26
3. The user telephone alarm notice .......................................................................................................................................... 27
Address code list ....................................................................................................................................................................... 29

AL-238
PPROGRAMMING GUIDE
3
Part 1 General description
This series of control panel is a kind of intelligent voice-based security technology prevention product that integrates many
advanced technologies and functions. It is widely used in various types of security systems such as villa community, perimeter
alarm system and office building.
The alarm system consists of a control keypad, a control panel, a remote control, an infrared detector, a door magnet, a smoke
detector, and a strong siren. Easy to install, simple to operate, can store 8 alarm calls (such as: user mobile phone number, fixed
phone number, etc.). It can be used alone (not connected to the Internet), or can be used for networking through GPRS/IP. It can
realize computer software management, cloud service alarm system connection, and easy integration with other systems. It is an
ideal choice for installing anti-theft alarm equipment in homes, business places, financial systems and other units.
1. AL-238P main function
1.1、 Features
Up to 40 zones can be connected: with 8 wired zones, up to 40 wired zones can be extended through the 485 expansion
module; up to 40 433MHz or LORA wireless zones can be extended.
The control panel itself supports 2 programmable outputs and one alarm output.
Each programmable output supports 200mA current, supports arming linkage, alarm linkage, software control.
The panel supports a siren interface, which can be set with active or passive output.
DC13.8V power input; 1 group of auxiliary power output (max 1500mA); 1 group of backup battery interface.
Extend 40 relay outputs through 485, which can be used as linkage output, and the
linked zones and attributes can be programmed.
Support 6 groups of timed arming and disarming functions, support Monday to
Sunday optional. Arm and disarm the entire control panel.
The control panel can communicate through phone, SMS, GPRS, IP and other alarm
notifications, support 8 SMS and telephone alarm numbers;
1 GPRS center, 2 IP centers; support alarm calls and SMS notifications. Telephone and text messages can remote arming/
disarming. Each group of SMS numbers can be set to disarm. You can call, program, and listen to the intercom on the phone.
Support 8 LED keypads, LED keypad can display the status of zone, programming, armed and disarmed.
The control panel supports 1 installer password and 1 programming password, 1 hijack password, 16 user passwords
(programmable disarming authority), and 40 zone operation passwords.
Support RS232 interface, support local program upgrade and access 232 serial
printer, real-time alarm printing.
Support 10 seconds recording, record the name of the installation location of the alarm control panel, broadcast the recording
when the alarm, let the alarm personnel know the alarm position at the first time.

AL-238
PPROGRAMMING GUIDE
4
Intelligent voice prompts, support for arming and disarming, programming, alarm voice broadcast, and zone broadcast
content synchronization zone name (use "local control panel name" + "zone name" + "alarm" combination). Voices include
local broadcasts and user phone voice broadcasts. Support remote reminders, off duty reminders and warning reminders for
networked alarm users.
The system comes with a real-time clock, and continues to run under power failure.
The system supports the black box function, which can save the latest 6000 alarm records and operation records separately.
Voice broadcast alarm record and time.
The voice broadcast is queried through the keypad operation: alarm record, operation record, system status, system time,
system version, and GPRS signal strength.
Modular design, the circuit board contains LORA module interface, IP module interface, GPRS module interface, PSTN
module interface. Users can choose.
Support 16 groups remote control, remote control one-button self-learning.
Support multiple arming and disarming methods such as outgoing arming, forced arming, staying arming, and quick arming.
1.2.Electrical performance index
Input power DC12-24V
Backup battery 12V7AH lead acid battery
Auxiliary output DC12V 1500mA
Static current 300mA
Alarm current ≥1000mA
Siren interface Active,DC12V 2000mA;or passive NO output
PGM output DC12V 200mA
Wired zone 2.2KΩ EOL Resistor
Wireless parameters 433MHz,encoding mode 1527,oscillation
resistance220KΩ
Operating temperature -10~55℃
Chassis size 255*265*88mm
Keypad size 161*120*28mm
Weight ≥3kg

AL-238
PPROGRAMMING GUIDE
5
2.System wiring instructions
2.1.System wiring diagram
2.2.AL-238P connection to the power supply
AL-238P adopts wide voltage design, can withstand DC12-24V power supply (factory standard DC13.8V 3A power supply); it will
prompt the system under voltage,when the power supply voltage is lower than 10V;
2.3.AL-238P and the keypad connection
The VCC, A, B, and GND of the keypad correspond to the red, green, yellow, and black
terminals of the master keypad, and up to 8 keypads are connected.
Alarm Control Panel System Wiring Diagram
Siren in terfa ce
Auxiliary output
Power input
PGM1
COM Z ONE 1
Siren interface
active output:
Siren interface
passive output:
plug-in AB and CD of JP2
plug-in BC of JP2
Battery
12V 7AH
RS232 port
Record button
MC1 microphone
Program upgrade
jumper
Password restore
jumper
4G module
Network module
433 wireless
IP network
Battery
PGM2
COM Z ONE 2
COM Z ONE 3
COM Z ONE 4
COM Z ONE 5
COM Z ONE 6
COM Z ONE 7
COM Z ONE 8
Keypad interface
power+
-power
DC power supply-1
Warning sign
Siren
Zone 1
Zone 2
NO PIR detector
NC PIR detector
power+
-power
DC power supply-2
Red
Grn
Yel
Blk
Master keypad
Red GrnYel Blk Central software
Note: Please use wires to plug-in the zone
terminals t hat do not need to be
connected to the detect or.
LoRa module

AL-238
PPROGRAMMING GUIDE
6
2.4.AL-238P connection to wired detector
The AL-238P series control panel can connect up to 8 wired detectors, and supports 4 kinds of zone wiring methods.
The specific connection method is as follows:
1、NC wired detector
connection
2、NO wired detector
connection
3、With 2.2K NO wired
detector connection
4、With 2.2K NC wired
detector
connection
Remarks: Description of the default wiring method between the AL-238P panel zone port and the wired detector
The portof the zone (zone 1 to zone 8) is connected to the "NC signal" of the detector by default;
Please use a wire to plug-in the zone terminals that do not need to be connected to the detector, or close it through keypad
programming. For programming, please refer to the "command 05" in the programming table of the manual;
2.2K
EOL resistor
2.2K
EOL resistor

AL-238
PPROGRAMMING GUIDE
7
2.5.AL-238P connection to siren
AL-238P siren interface description
Siren interface active output: plug-in AB and CD of JP2
Siren interface passive output: plug-in BC of JP2
As shown in FIG:
Plugged-in AB and CD of JP2 jumper of AL-238P panel, the siren interface is active output, and the output power
consumption is DC12V 2000mA;
Plugged-in BC of JP2 jumper of AL-238P panel, the siren interface is passive output;
2.6.AL-238P connection to bus device (8 zones extend module, linkage relay, slave keypad)
The AL-238P control panel is connected to the bus device (8 zones extend module, linkage relay module) through the RS485
keypad communication interface. The power supply of the bus device and its detector is recommended to be powered by a
separate power supply. The total power consumption of all devices attached to the same power supply should not exceed the
power rating of the power supply
Alarm Control Panel System Wiring Diagram
Siren in terfa ce
Auxiliary output
Power input
PGM1
COM Z ONE 1
Siren interface
active output:
Siren interface
passive output:
plug-in AB and CD of JP2
plug-in BC of JP2
Battery
12V 7AH
RS232 port
Record button
MC1 microphone
Program upgrade
jumper
Password restore
jumper
4G module
Network module
433 wireless
IP network
Battery
PGM2
COM Z ONE 2
COM Z ONE 3
COM Z ONE 4
COM Z ONE 5
COM Z ONE 6
COM Z ONE 7
COM Z ONE 8
Keypad interface
power+
-power
DC power supply-1
Warning sign
Siren
Zone 1
Zone 2
NO PIR detector
NC PIR detector
power+
-power
DC power supply-2
Red
Grn
Yel
Blk
Master keypad
Red GrnYel Blk Central software
Note: Please use wires to plug-in the zone
terminals t hat do not need to be
connected to the detect or.
LoRa module

AL-238
PPROGRAMMING GUIDE
8
8 zones expansion module address dial code description: the address dial code range is 0-4; the address dial 0, the zone
number represents 1-8 zone, dial 1 represents 9-16 zone, and so on;
Linkage module address dial code description: the address dial code range is 64-66; the address dial 64, the relay linkage
output point is 1-16, dial 65 represents 17-32 channels, and so on;
Keypad address description: the address range is 0-7; the address is 0, it represents the main keypad, 1 represents the slave
keypad, and so on;
2.7.Backup battery
Backup battery 12V/7AH, the red line of the control panel battery interface is connected to the battery + and the black wire is
connected to the battery -. When the power supply fails, the control panel automatically switches to the backup power
supply.
3. Main board LED lights status description
LED Light LED function LED status
LED1 Power light Light on when in power
LED2 Serial communication light Light on when serial port receives the data
LED3 485 communication light Light on when 485 communication is normal and
flashing, light off when abnormal
LED4 System running light Light flashes once every 1 second when system
runs
normally
LED5 GPRS communication light Light flashes once every time GPRS receives data
LED6 IP module communication
light
Light flashes once every time IP receives data
LED7 LORA communication light Light flashes once every time LORA receives data
GrnYel Blk
Keypad interface
DC power supply-2
8 zones expansion
module(address 0-4)
Partition keypad
(address 1-7)
16-output module
(address 64-66)
Red Grn yel B lk

AL-238
PPROGRAMMING GUIDE
9
4.Main parts description
4.1.Keypad
Keypad layout:
The keypad is mainly divided into two areas: the display area and the keypad
area.
The keypad display area shows the running status of the control panel: such
as arm, alarm, communication , power supply, program, bypass, and zone.
The keypad area is mainly divided into: password input and programming
command input, system arming, disarming, staying arming, bypass and other
function buttons.。
Keypad display status description:
Power light Light on when in power
Arming light Light on when system armed, off when system disarmed
Bypass light Light on when staying armed
Program light Light on when in programming
Communication light Light on as long as one center and software communication is normal
Alarm light Light on when any zone alarm
1-24 zone light The zone lights are off when zones are normal; the zone light will be on the zone is
triggered; the zone light will be on for a long time when zone alarms and the zone light will
flash after the alarm time expires.
4.2.Module function
4G module Network module
4G module is the panel GPRS、GSM mobile network
expansion module; the status of the module LED is as
follows:
LED1=Module power-on status
Constantly light on means the module is turned on; light off:
not initialized or turned off;
LED2=SIM status light;
Constantly light on means the SIM card
is detected, light off means the SIM card is not detected.
LED3=receiver indicator:
When the module serial port receives data, the light is on;
The module is a network extension module of alarm panel,
which can realize TCP/IP communication and achieve the
network alarm function.

AL-238
PPROGRAMMING GUIDE
10
when there is no data, the light is off;
LED4=Send indicator:
When the module serial port sends data, the light is on; when
there is no data, the light is off;
LED5=Network indicator:
Long flashing once every 3s: successful registration of the
network; flashing once every 800ms: network off; light off: no
network registered
LED6=Module power light:
Light on: module power supply; light off: module no power
supply
8 zones module LORA module
8 zones module address dial code range 0-4; the address
dial 0, the zone number represents 1-8 zone, dial 1
represents 9-16 zone, and so on.
LoRa module: The LoRa module is the LoRa communication
extension module of the alarm panel, which supports the
access of LoRa wireless alarm device.
Inhaltsverzeichnis
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung