Amprobe TR300 Bedienungsanleitung

TR300
Temperature and
Relative Humidity
Data Logger
Users Manual
• Mode d’emploi
• Bedienungshandbuch
• Manual d’Uso
• Manual de uso
• Användarhandbok

1
English
TR300
Temperature and Relative
Humidity Data Logger
Users Manual
TR300_Rev001
© 2008 Amprobe Test Tools.
All rights reserved.

3
Sensor
2.5”X 2.0” LCD display
Speaker
Alarm LED
Record LED
Start/Stop to turn on and off
the unit
Mode
Set
Up scroll
Down scroll
9V DC adaptor (>= 500mA.
Depth:9mm Inner: 1.35mm.
Outer: 3.5mm) Not Included
USB adaptor (USB cable is
optional accessory)
Tripod mounting screw (tripod
not included)
Primary display: Displays the measured
temperature in °C or °F.
DP: Dew point indicator
REC: recording indicator
Low battery indicator
Secondary display: Displays the air
humidity
Date indicator
Time indicator
Date and time display: Alternates
between date and time display
DP
REC 20.8 °C
36.5 %
Y-M-D 08-02-13
1
2
5
3
4
6789
1 0
12
1 1
1 3
%
DP
REC
Y-M-D
H:M:S
2
3
4
5
6
7
1
8

4
TR300
Temperature and Relative Humidity Data Logger
CONTENTS
Introduction.........................................................................................................................................5
Unpacking and Inspection..................................................................................................................5
Operation ............................................................................................................................................5
Setting Mode .................................................................................................................................5
Sample point:.................................................................................................................................6
Start Mode: ....................................................................................................................................6
Start Time: ......................................................................................................................................7
Sample Rate ...................................................................................................................................8
Alarm Set........................................................................................................................................9
Real Time......................................................................................................................................10
Switch from °F to °C.....................................................................................................................10
Dew point measurement: DP......................................................................................................10
Instrument Connection.....................................................................................................................10
RS232 PC interface capabilities ...................................................................................................11
Download Suite Software installation .......................................................................................11
Operation.....................................................................................................................................11
Troubleshooting................................................................................................................................11
Specifications.....................................................................................................................................12

5
INTRODUCTION
The TR300 Temperature and humidity logger is well suitable to monitor indoor air quality. It
is designed with a wall-mounted hook in the back for easy installation. It has a very large LCD
display, an audible and visible alarm, and a quick response sensor to help monitor easily the
air temperature and humidity. It also has 16K memory capacity storage to record and save
continuous readings.
Please read this manual thoroughly before operation. You will find it very easy to operate and
a valuable instrument to measure & record the air temperature & humidity.
UNPACKING AND INSPECTION
The standard package of this product contains:
1 X TR300 meter
1 X Instruction Manual
1 X Download Suite CD
1 X USB Cable
4 X AA battery
OPERATION
Turn ON and OFF the unit
Press START/STOP pushbutton for less than 1 sec•
The display will show current temperature, humidity, the date and time in alternate fashion.•
Setting Mode (See Fig 4 for Symbols meaning)
Press SET pushbutton to enter the setting mode or use the software program .1.
Use Up and Down pushbuttons to select from:2.
Sample point: ‘PtS’ & ‘P1’ show on the display•
Start mode: Stn’ and ‘P2’ show on the screen•
Start Time: ‘Stt’ & ‘P3’ show on the display•
Sample rate: ‘Sr’ & ‘P4’ show on the screen•
Alarm set: ‘AL’ & ‘P5’ show on the screen•
Real time: ‘rtC’ & ‘P6’ shown on the display•

6
Sample point:
From ‘Pts’ & ‘P1’, press SET key•
Press up and Down pushbuttons to select the sample point from 1h(1000)…….16h(16000).•
The sample point will be divided in half: ½ for temperature and ½ for humidity. Example:
16000 points= 8000 Temp + 8000 RH
Press SET to save and return to P1•
Press MODE to escape without saving the value•
Start Mode:
Press Up and Down keys to select from:
Repeat: ‘rEp’ is displayed on the bottom of the screen. In this mode the meter will•
automatically record again once the memories are uploaded to a PC.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘rEp’
Press SET to save and return to P2
Press MODE to escape
Press Up and Down Press SET to save

7
Key Start: ‘hEy’ is displayed on the bottom of the screen. In this mode, the meter will start•
recording when you press Start/Stop for more than 2 seconds.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘hEy’
Press SET to save and return to P2
Press MODE to escape
Immediately: ‘|Nn’ is displayed on the bottom of the screen. In this mode, the meter will•
start recording immediately after you save the setting.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘|Nn’’
Press SET to save and return to P2
Press MODE to escape and start recording.
To stop the recording, press and hold Start/Stop for more than 2 seconds.
Schedule: ‘SCh’ is displayed on the bottom of the screen. In this mode, the meter will start•
recording from the preset date and time.
From ‘Stn’ & ‘P2’, press SET key
Press Up or Down key to select ‘SCh’’
Press SET to save and return to P2
Press MODE to escape
Start Time:
Press SET to enter the setting mode•
Press Up or Down key to select ‘Stt’ & ‘P3’•
Press SET to enter edit mode for year ‘YEr’•
Press Up or Down key to adjust the year•
Press SET to enter edit mode for month ‘Mon’•
Press Up or Down key to adjust the month•
Press SET to enter edit mode for day ‘dAt’•
Press Up or Down key to adjust the day•
Press SET again to enter the edit mode foe hour’Hor’•
Press Up or Down key to adjust the hour•
Press SET again to enter the edit mode of minute’NI n’•
Press Up or Down key to adjust the minute•
Press SET again to enter the edit mode for Second ‘Sec’•
Press Up or Down key to adjust the second•
Press SET to save the date and time•
Press MODE to quit•

8
Sample Rate
Press SET key to enter sample rate mode•
Press Up or Down key to select ‘Sr & P4’•
Press SET to enter edit mode for HOUR•
‘Hor’
Press Up or Down key to adjust the hour•
Press SET to enter edit mode for MINUTE•
‘N| n’
Press Up or Down key to adjust the•
minute
Press SET to enter edit mode for SECOND•
‘SEc’
Press Up or Down key to adjust the second•
Press SET to save and return to P4•
Press mode to quit and return to main menu•
Y-M-D
Y-M-D
Y-M-D
H:M:S
H:M:S
H:M:S

9
Alarm Set
Press SET key to enter the alarm setting•
Press Up or Down key to select ‘AL & P5’•
Press set key to edit HIGH temperature ‘tH’•
Press Up or Down key to adjust the high temperature•
Press set key to edit LOW temperature ‘tLo’•
Press Up or Down key to adjust the low temperature•
Press set key to edit HIGH humidity ‘HH’•
Press Up or Down key to adjust the high humidity•
Press set key to edit LOW humidity ‘HL’•
Press Up or Down key to adjust the low humidity•
Press SET to save and return to P5•
Press MODE to quit and return to main menu•

10
Real Time
Press SET to enter real time setting•
Press Up or Down key to select ‘rTC & P6”•
Press SET to edit YEAR ‘yEr’•
Press Up or Down key to adjust the year•
Press SET to edit MONTH ‘Non’•
Press Up or Down key to adjust the month•
Press SET to edit DAY ‘dAt’•
Press Up or Down key to adjust the day•
Press SET to edit HOUR ‘Hor’•
Press Up or Down key to adjust the hour•
Press SET to edit MINUTE ‘Mi n’•
Press Up or Down key to adjust the minute•
Press SET to edit SECOND ‘Sec’•
Press Up or Down key to adjust the second•
Press SET to save and return to P6•
Press MODE to quit and return to main menu•
Switch from °F to °C
Press and release MODE key to change from °F to °C•
Dew point measurement: DP
Press and hold MODE key for dew point reading•
Press and release MODE key to change DP from °F to °C•
Press and hold MODE key to return to temperature reading.•
INSTRUMENT CONNECTION
Plug the RS232 cable to the meter to turn it ON.1.
Connect the meter with the PC using the RS232 provided2.
Start the Download Suite software program3.
H:M:S
Andere Handbücher für TR300
1
Inhaltsverzeichnis
Andere Amprobe Datenlogger Handbücher