ANDO Technik Galcon 800248 Bedienungsanleitung

Electrically Operated Advanced
Computerized Irrigation Controller
Installation and Operating Manual
Controller Model 800248 –
Operating 1 to 24 valves + Main Valve or Pump
Controller Model 800244 –
Operating 1 to 4 valves + Main Valve or Pump

- 2 -
Controller Features:
• Control the operation of 1 to 24 valves + main valve or pump
• Operating 24 VAC electrical valves
• Sensor input
• Weekly or cyclical irrigation programming for a number of values
• Independent weekly or cyclical irrigation programming for individual
valves
• Fertilization programming of individual valves
• Programming for garden lighting system
• Optional percentage modication of irrigation duration
• Irrigation duration from 1 minute up to 9 hours
• Irrigation frequency from once daily to once every 30 days
• Computerized manual operation of individual valves or valve groups
• Detection of short circuits; short-circuited valve cutoff with visual
warning
• Memory backup of program for 20 years (batteries unnecessary)
• Clock backup with 9V battery (not included)
• Galcon's warranty and service
Input power: AC 230V 50Hz
Output power: 24V 20VA
Environmental conditions: -33°C - 65°C, 2000 m altitude
IP54

- 3 -
CONTENTS
Installation Preparation
1. Adjusting irrigation controller to valves 5
2. Manual-Mechanical Operation 5
Installation and Wiring Instructions 6
1. Controller installation 7
2. Adding to or Replacement of 4-Valve Model 8
3. Connecting solenoid wires 9
4. Safety instructions 12
5. Connecting controller to power source 13
6. Sensor connection 14
Programming the Irrigation Controller
1. General Information 15
2. Setting current time and day of the week 16
Programming of valve-group irrigation 17
1. Programming weekly irrigation 18
2. Programming cyclic irrigation 20
3. Selecting valves for weekly/cyclic programming 21
4. Setting irrigation duration times for weekly/cyclical
programming 22

- 4 -
Programming controller for Individual valve – Independent
Program I
1. Valve selection for Independent Program I 23
2. Setting irrigation duration time for Independent Program I 24
3. Irrigation by day of the week 25
4. Selecting cyclic irrigation schedule 27
Advanced Controller Programming for Valve-Groups and
Independent Program I
1. Fertilization supplement 28
2. Fitting valve to sensor 29
3.Garden lighting system 30
4. Irrigation duration extended or shortened according
to percentage 31
5. Suspension 32
6. Computerized manual operation 33
7. Testing 34
8. Program RESET 34
Maintenance
1. Low battery warning 35
2. Missing AC power 35
3. Filter 35
4. Water pressure 35
5. Troubleshooting detection and repair 36
Additional Accessories 37

- 5 -
The irrigation controller is designed to operate
standard electrical valves of up to 24VAC 2.2 W.
The valves are not supplied with the controller.
1. Close the main water valve.
2. Install valves in the irrigation system.
The main electrical valve may be installed at the
entrance to the irrigation system. The main valve
will open automatically when one of the valves is
open, and will automatically close with the closing
of the last valve.
The main valve is shown on the display panel and
on the connection toolbar by the letter M.
It is not necessary to program the main valve.
2. Mechanical Manual Operation
The irrigation valves may be opened/closed
unrelated to the operation of the controller. This
mode is useful when irrigation is necessary
immediately, and either a lock of time or
knowledge makes operating the irrigation
controller impossible.
The manual operating handle is located under the
solenoid.
1. To open the valve turn the handle counter-
clockwise (illustrated in 2)
2. To close the valve turn the handle clockwise
(illustrated in 1)
• When the electricity is turned on the valve
cannot be closed manually.
• To operate a valve with the controller, the
manually operated handle must be in a closed
position (1).
1. Adjusting the Irrigation Controller to the Valves
ATTENTION !
Direct water flow according to the arrow
above entrance pipe (A). (Illustration 1)
ATTENTION !
If there is a main manual valve, this
should also be opened manually
Installation Preparation

- 6 -
Installation and Wiring Instructions
ATTENTION !
It is recommended to position controller in
an accessible place and at eye-level.
• Open the controller door with the attached key.
• To get to the connector board, release the lock screws on the left
side of the controller beneath the main cover and open the panel.

- 7 -
Installation and Wiring Instructions
1. Controller Installation
Install the controller on the wall or in a controller cabinet by mounting it with two screws at the
designated holes . Use the included plugs to cover these screws.
Place a 9V Alkaline Non-rechargeable battery in the appropriate place.

- 8 -
Installation and Wiring Instructions
2. Adding or Replacing 4 Valve Module
Attention: Modules may be added or replaced only in the AC-800248 Model
In order to add or replace a 4 valve module the following procedures must be performed:
1. Turn selector to Testing mode.
2. Turn off electricity.
3. Wait one minute.
4. Remove battery.
5. With a "cross-head" screwdriver, open screws
on front of module.
6. Add or replace module with a push or pull as
shown in illustration.
7. Fasten screws at front of module.
8. Replace battery in position.
9. Turn on electricity.
* The number of valves the controller will now
operate will appear on the LCD display.
* The current time must be set.
THE PROGRAMS INSTALLED IN THE CONTROLLER WILL BE STORED
DESPITE CUTOFF FROM ELECTRICITY VOLTAGE (MEMORY OF 20 YEARS!)

- 9 -
Installation and Wiring Instructions
3. Connecting Solenoid Wires
General
Two wires identical in color and polarity are connected to each solenoid. One wire (either one) must
connect to the desired valve in module. The second wire must be connected to joint C point in
model. Distance between controller and valves usually are longer than solenoid wires. The valve
control cable may be used to connect wires. The valve control cable connects the controller to
solenoid connector box.
Valve Control Cable Features
• Valve control cable transmits only 24 volt
• Number of wires in valve control cable must be at least the same number of selected valves, in
addition to two – one for master valve and one for joint wire. To facilitate wiring, it is recommended
to use differently colored wires.
• It is recommended to use cable with larger number of wires to allow for additional valve
connections in future, or in order to substitute faulty wire.
• Minimum width of valve control cable wires must be 0.5 mm2. If valves are at a distance of more
than 100 meters from controller, consultation with Galcon is necessary in order to set correct width.
• Valve control cable must be xed on wall with nail clasps or alternately underground in properly
protective pipe.
• It is recommended not to use a cable composed of several connected parts. If necessary, the
cable parts should be connected with protective connection box.
• Connection of valve control cable to valves must be made with electrical connectors in properly
protective connector box (not included). It is recommended at the number if connection points in
designated box exceed number of valves.
THE PROGRAMS INSTALLED IN THE CONTROLLER WILL BE STORED DESPITE
CUTOFF FROM ELECTRICITY VOLTAGE (MEMORY OF 20 YEARS!)

- 10 -
Installation and Wiring Instructions
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis