Anolis ArcPower Rack Unit Pixel CE: ArcPower Rack Unit Pixel... Bedienungsanleitung

version 1.7

2
Table of contents
1. Important safety instructions........................................................................................ 3
2. Operating determinations.............................................................................................. 3
3. Description of the ArcPower Rack Unit Pixel .............................................................. 5
4. Conguration of terminals ..................................................................................................... 6
5. Installation....................................................................................................................... 6
5.1 Connection to mains .................................................................................................. 6
5.2 Installing the ArcPower Rack Unit Pixel into a rack.................................................... 7
5.3. DMX 512 operation ................................................................................................... 7
5.4. Dots connection ........................................................................................................ 8
6. DMX protocol ................................................................................................................. 9
7. Fixture menu................................................................................................................. 10
7.1 Conguration............................................................................................................ 10
7.2 Information ............................................................................................................... 14
7.3 Personality ............................................................................................................... 15
7.4 Manual mode ........................................................................................................... 17
7.5 Stand-alone setting ................................................................................................. 17
7.6 Special Functions..................................................................................................... 17
8.Technical Specications............................................................................................... 20
9. Maintenance ................................................................................................................. 22
9.1 Replacing the air lters............................................................................................. 22
9.2 Replacing the main fuse........................................................................................... 23
9.3 Disposing of the product .......................................................................................... 23
10. ChangeLog ................................................................................................................. 23
ArcPower Rack Unit Pixel

3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Important safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
-follow all instructions and heed all warnings in this manual.
CAUTION!
Be careful with your operations. With a high voltage you can suer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
WARNING
To prevent injury, this device must be securely attached to a rack in accordance
with the installation instructions.”
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators or other devices that produce heat.
Do not use this device near water. Clean only with dry cloth.
Only use accessories specied by the manufacturer.
Refer all servicing to qualied service personnel. Servicing is required when the device has been damaged
in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into
the device, the device has been exposed to rain or moisture, does not operate normally, or has been dropped.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both
overload and short circuit protection.
This device falls under protection class I.Therefore the ArcPower Rack Unit Pixel
has to be connected to a mains socket outlet with a protective earthing connection!
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched o until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.

4
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fastened.
The maximum ambient temperature 50° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not qualied
for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!

5
3. Description of the ArcPower Rack Unit Pixel
1 - Handle
2 - Air lter holder
3 - graphic touch screen
4 - LED pixel zone 1 output
5 - LED pixel zone 8 output
6 - DMX OUT (3-pin XLR)
7 - Input for trigger and
12V output
8 - DMX IN (3-pin XLR)
9 - Ethernet (RJ45)
10 - Mains input
11 - Fuse holder
12,13 - Free slots for optional
zones (e.g. Fan zone, Real Time
Zone,0-10V Zone)
Rear panel

6
4. Conguration of terminals
DMX In/Out Ethernet
(XLR mounting sockets) (RJ 45 female)
LED pixel zone output Trigger input and 12V output
5. Installation
5.1 Connection to mains
CAUTION!
The ArcPower Rack Unit Pixel must be installed by a qualied electrician in
accordance with all national and local electrical and construction codes and
regulations.
These servicing instructions are for use by qualied service personnel only.
To reduce the risk of electric shock do not perform any servicing other than that
contained in the operating instructions unless you are qualied to do so.
This device falls under protection class I. Therefore the ArcPower Rack Unit Pixel
has to be connected to a mains socket outlet with a protective earthing connection.
The ArcPower Rack Unit Pixel CE is equipped with auto-switching power supply that automatically adjusts to any
50-60Hz AC power source from 100-240 Volts. Connect the xture to the mains by means of inbuilt power cord.
The ArcPower Rack Unit Pixel US (ArcPower Rack Unit Pixel US (LV)) is equipped with auto-switching power
supply that automatically adjusts to any 50-60Hz AC power source from 100-277 Volts. Connect the xture to
the mains by means of inbuilt power cord.
If you need to install a cord plug on the power cord to allow connection to power outlets, install a grounding-type
Pin 1: Shield
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 1: TX+ Pin 5: Not connected
Pin 2: TX- Pin 6: RX-
Pin 3: RX+ Pin 7: Not connected
Pin 4: Not connected Pin 8: Not connected

7
(earthed) plug, following the plug manufacturer’s instructions. If you have any doubts about proper installation,
consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Green /Yellow Green Earth
This device falls under class one and must be earthed (grounded).
Wiring and connection work must be carried out by qualied sta.

8
5.2 Installing the ArcPower Rack Unit Pixel into a rack
The ArcPower Rack Unit Pixel is designed for mounting into 19-inch equipment rack.
Fasten the ArcPower Rack Unit Pixel into rack by means of two screws on each side the ArcPower Rack Unit
Pixel front panel.
5.3. DMX 512 operation
The ArcPower Rack Unit Pixel is equipped with 3-pin XLR sockets for DMX input and output. Only use a shiel-
ded twisted-pair cable designed for RS-485 and 3-pin XLR connectors in order to connect the xture with the
DMX controller or one xture with another.
To build a DMX chain.
1. Unplug xtures from the mains before installation.
2. Connect the LED modules to the ArcPower Rack Unit Pixels.
3. Connect ArcPower Rack Unit Pixels each other. Max. 32 xtures may be connected on a DMX link.
Terminate the DMX link by installing a termination plug in the output of the last xture.
The termination plug is a male 3-pin XLR plug with a 120 Ohm resistor soldered between Signal (–)
and Signal (+).
4. Connect ArcPower Rack Unit Pixels to mains.
5. Set each ArcPower Rack Unit Pixel.
6. Connect the DMX controller to the rst xture.

9
5.4. Dots connection
Dots (ArcDot-CE, ArcDot-US, ArcSource Outdoor 4MC-Pixel-CE, ArcSource Out 4MC Pixel -US) can be can
be interconnected directly or by using T- connectors see the picture below.
To connect Dots
1. Disconnect the ArcPower RackUnit Pixel from mains.
2. Connect Dots to the ArcPower RackUnit Pixel. Number of dots depends on version of the ArcPower Rack
Unit Pixel and length of cables in the installation (see table below). Connect active terminators to each Dots line.
3. Connect the ArcPower RackUnit Pixel to mains.
4. Run procedures "Search Pix" and "Sort Pix" from the menu "Conguration" (Conguration-->ArcZone
Pixel--> Commands)
5. Save adjusted values using the the option "Save" It is important to save Dots conguration at every change
in the menu "Commands".
6. Disconnect the ArcPower RackUnit Pixel from mains and replace active terminators by passive terminators*.
7. Connect the ArcPower RackUnit Pixel to mains and to the pixel control system (e.g. Robe Media Server).
* Active terminators can remain permanent connected if there is place for them (they are bigger than passive
terminators).
Always disconnect the ArcPower Rack Unit Pixel from AC power before
connecting/disconnecting pixel module!
Example of installation:
Direct connection
Connection by means of
T-connectors
The minimum cable length of 0.3m between
two T-connectors has to be kept in case that the
pixel searching and sorting is executed from
the ArcPower Rack Unit Pixel menu.
Max. number of
Dots per output
L max (max. length of cable from AP Rack
Unit Pixel to terminator on one pixel output)
ArcPower Rack-
Unit Pixel CE
ArcPower Rack-
Unit Pixel US
ArcPower Rack-
Unit Pixel US (LV)
25 100 m
24
23
22
21
20 20 m 20 m
19 60 m 40 m
18 75 m 50 m
17 90 m 60 m
16 100 m 65 m
15 70 m
14 80 m
13 90 m
12 100 m

10
6. DMX protocol
3CH mode
(RGB)
4CH mode
(RGBW) Value Function Type of
control
Pixel 1
1 1 0-255
Red
Red LED saturation control (0-100%) proportional
2 2 0-255
Green
Green LED saturation control (0-100%) proportional
3 3 0-255
Blue
Blue LED saturation control (0-100%) proportional
-40-255
White
White LED saturation control (0-100%) proportional
Pixel 2
4 5 0-255
Red
Red LED saturation control (0-100%) proportional
5 6 0-255
Green
Green LED saturation control (0-100%) proportional
6 7 0-255
Blue
Blue LED saturation control (0-100%) proportional
-80-255
White
White LED saturation control (0-100%) proportional
Pixel 3
7 9 0-255
Red
Red LED saturation control (0-100%) proportional
8 10 0-255
Green
Green LED saturation control (0-100%) proportional
911 0-255
Blue
Blue LED saturation control (0-100%) proportional
-12 0-255
White
White LED saturation control (0-100%) proportional
:
Pixel 128
382 509 0-255
Red
Red LED saturation control (0-100%) proportional
383 510 0-255
Green
Green LED saturation control (0-100%) proportional
384 511 0-255
Blue
Blue LED saturation control (0-100%) proportional
-512 0-255
White
White LED saturation control (0-100%) proportional
:
Pixel 170
508 -0-255
Red
Red LED saturation control (0-100%) proportional
509 -0-255
Green
Green LED saturation control (0-100%) proportional
510 -0-255
Blue
Blue LED saturation control (0-100%) proportional
- - 0-255
White
White LED saturation control (0-100%) proportional
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Anolis Controller Handbücher