Anyload OCS-T Bedienungsanleitung

OCS‐T
HighResolutionDigitalCraneScale
UserGuide

Content
1. Safety Guide .............................................................................. 1
2. Features ..................................................................................... 1
3. Specifications ............................................................................ 2
4. Capacity .................................................................................... 3
5. Dimension & Weight ................................................................. 3
6. Display & Keys ......................................................................... 4
Scale Keys............................................................................. 4
Remote Keys ......................................................................... 4
Indicators .............................................................................. 5
Message ................................................................................ 5
7. Operations ................................................................................. 6
Power On/Off ........................................................................ 6
Zero ....................................................................................... 6
Tare In/Out ............................................................................ 6
Lock/unlock .......................................................................... 7
Accumulate ........................................................................... 7
View ...................................................................................... 7
Delete Last Weight ................................................................ 7
Clear All Weight .................................................................... 8
Unit Switch ........................................................................... 8
8. User Setup ................................................................................. 8
Auto-Off Timing ................................................................... 8
Display Brightness ................................................................ 9
Idle Mode Timing ................................................................. 9
9. Battery Maintenance ................................................................. 9
10. Troubleshooting .................................................................... 10
11. Loading Procedures ............................................................... 12
Pleasereadthismanualcarefullybeforeusing.Version:V1.0A‐3

High Resolution Digital Crane Scale User Guide
Page1of12
1. SafetyGuide
Forgoodperformanceandprecisemeasurement,becareful
withdailyoperationandmaintenance.
DoNOToverloadscale.Thiswilldamageloadcellandvoid
warranty.
DoNOTleaveloadhungonthescaleforlong.Thiswill
decreasescale’saccuracyandshortenloadcell’slife.
Inspectshackleandhookbeforeusing.Checkclips,pinsand
screwsregularly.
Checkbatteryfrequently.Whenscalerunsoutofpower,charge
batterywithitsdedicatedcharger.
Rotateloadratherthanscaleifneeded.
DoNOTusescaleunderthunderorrain.
Hangscaleonshelfindryandwell‐ventilatedroom.DoNOT
placescaleonthegrounddirectly.
DoNOTattempttorepairscaleyourself.Contactyourlocal
representative.
2. Features
Thisscaleisacombinationofsoundandprovenmechanical
design,withtoday’smostadvancedelectronicstoprovideasuperb
featureset.Itisversatile,reliable,accurateandeasytooperate.
SuperbQuality.StrictlyinaccordancewithOIMLR76,Chinese
GB/T11883‐2002nationalstandards,andEuropeanCE
directives.
GreatSafety.Aluminum‐castingcase,highfirmhookand

High Resolution Digital Crane Scale User Guide
Page2of12
shackle,dedicatedweighingloadcellforsafetyinstallation.
StrongReliability.Cutting‐edgetechnology,qualityintegrated
circuitforhighperformanceandlongtimestability.
BroadApplicability.Popularandapplicableinstorage,textile,
metallurgyindustry,andsoforth.
EasytoUse.Ultra‐redremotecontrollingdesign.Easyto
operateonthescaleorindistance.
CompleteFunction.Resolutionswitch,unitconversion,auto
power‐off,batteryinspection,etc.
3. Specifications
AccuracyClassChineseGB/T11883‐2002ClassIII
EquivalenttoOIMLR76
TareRange100%F.S.
ZeroRange4%F.S.
StableTime≤10sec
Overload100%F.S.+9e
SafetyLoad150%F.S.
UltimateLoad400%F.S.
Battery6V/4.0Ahleadacidrechargeablebattery.
Charger100~220VAC50/60Hzinput
7.2VDC/1000mAoutput
Display35mm(1.4inch)LEDmodule
Op.Temp.‐10℃~+40℃
Op.Humidity20℃≤90%

High Resolution Digital Crane Scale User Guide
Page3of12
4. Capacity
ModalMax.Cap.Min.Cap.Res.Division
OCS‐1‐T1,000kg10kg0.5kg2,000
OCS‐2‐T2,000kg20kg1kg2,000
OCS‐3‐T3,000kg20kg1kg3,000
OCS‐5‐T5,000kg40kg2kg2,500
5. Dimension&Weight
L
255
210
A
B
C

High Resolution Digital Crane Scale User Guide
Page4of12
ModalABCLN.W.
OCS‐1‐T68mm112mm40mm420mm11.0kg
OCS‐2‐T68mm112mm40mm420mm11.0kg
OCS‐3‐T68mm112mm40mm420mm11.0kg
OCS‐5‐T68mm112mm45mm450mm12.5kg
6. Display&Keys
ScaleKeys
KeyNameFunction
On/OffPress1stopoweron/offscale.
Returntoweighingmode.
ZeroManualZero.
Increaseflashingdigit.
TareTarein/out.
Rightscrollflashingdigit.
HoldLock/unlockreading.
Confirm.
RemoteKeys
KeyNameFunction
ZeroSameas.
TareSameas.
HoldSameas.
Acc.Accumulateweight.
Decreaseflashingdigit.

High Resolution Digital Crane Scale User Guide
Page5of12
Del.
Deletelastweight.
Clearallweight.
Leftscrollflashingdigit.
F1View.
Inputdecimalpoint.
F2Unitswitch.
OffPress1stopoweroff.
Returntoweighingmode.
2nd2ndfunction.
Indicators
LEDNameNote
ST B
.
Stablelitwhenweightisstable
Z ERO
Zerolitwhenweightisatzero
TARE
Taredlitwhenscaleistared
H OL
D
Holdlitwhenscaleislocked
lb
lblitwhenunitislb
kg
kglitwhenunitiskg
Message
MessageStandforNote
----- detectweight
||||? inIdleMode
Setup SETUPUserSetupMenu
Bat?? BATterybatterylifepercentage
P0000 PasswordinPasswordMode
|end| ENDsaveandexit
|off| OFFpoweroff

High Resolution Digital Crane Scale User Guide
Page6of12
|over OVERloadoverloading
|2nd| 2ND2ndfunction
|err| ERRorinvalidoperation
|acc| ACCumulateaccumulateweight
|del| DELetedeletelastweight
|Clr| CLeaRdeleteallweight
7. Operations
PowerOn/Off
Pressfor1stopower‐onscale.Scaleperforminitialization
andpower‐ontest,*****showstwice,thencapacity|5000
shows,batterylifepercentagebat90shows,weightdetection
-----showsandthenautozero.
ForinformationaboutAuto‐Zero,refertoScaleConfigurationin
TechnicalManual.
Pressor for1stopower‐offscale.Batterylife
percentagebat90shows,offmessage|off|shows,andthencut
offpower.
Zero
Pressor tozero.
Z ERO
lighton.
Ifloadisinmotion,ortared,oroutofManual‐ZeroRange,|err|
shows.
ForinformationaboutManual‐ZeroRange,refertoScale
ConfigurationinTechnicalManual.
TareIn/Out
Ingrossmode,pressor totarein.
TARE
lighton.

High Resolution Digital Crane Scale User Guide
Page7of12
Ifloadisinmotion,ornegative,oroutofTareRange,|err|
shows.
Tarewillreducetheapparentoverloadrangeofscale.For
example,ifa5000*2kgscalehasa1000kgcontainerasitstare,
thescalewilloverloadatanewweightof4018kg(5000–1000+
additional9divisions).
Innetmode,pressor totareout.
TARE
lightoff.
Lock/unlock
Pressor tolockscreen.
H OLD
lighton.
Pressor tounlockscreen.
H OLD
lightoff.
Accumulate
Presstoaccumulatecurrentweight.
|acc|shows,indicatingweightisaccumulated.Scaleuses
displayedweight,sogrossornetweightisaddedintothesame
accumulator.
Ifloadisinmotion,ornegative,ordoesnotreturntozero
before,|err|shows.
View
PresstoenterViewmode.
Displayflashesaccumulatedweight.
Pressor toviewhigh5‐digitorlow5‐digit.
Pressor toexitViewmode.
DeleteLastWeight
Presstodeletelastaccumulatedweight.
|del|shows,indicatinglastaccumulatedweightisdeleted.
Deletefunctiononlydeletesthelastweight.

High Resolution Digital Crane Scale User Guide
Page8of12
Iflastaccumulatedweighthasbeendeleted,|err|shows.
ClearAllWeight
Pressfirstandthenpress toclearallaccumulated
weight.
|clr|shows,indicatingallweightiscleared.
UnitSwitch
Presstoswitchunitinbetweenkg,lb,andUserUnit.
Whenunitiskg,
kg
LEDlighton.Whenunitislb,
lb
LEDlight
on.WhenunitisUserunit,
kg
and
lb
LEDalllightoff.
FormoreinformationaboutUserUnit,refertoScale
ConfigurationinTechnicalManual.
8. UserSetup
Pressfirstandthenpress or toenterUserSetup
menu.setupshows.
Auto‐OffTiming
Pressor toenterAuto‐OffTiming. off??
shows.
Pressor and tochangetimingvalue.
Auto‐OffTimingcanbesetto:0(disabled),5(5min),10(10min),
15(15min),30(30min),60(60min).Itisdisabledbydefault.
Auto‐Offfunctionmaximizesscale’sbatterylifeagainstpeople’s
carelessnessnottopoweroffscalewhenit’snotworking.
Auto‐Offstartscountdowntimerwhenthere’snoactionorload
isstable.Anykeypressingormotioninloadrestarts
countdowntimer.
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Anyload Skala Handbücher

Anyload
Anyload EC100 Bedienungsanleitung

Anyload
Anyload T15 Series Bedienungsanleitung

Anyload
Anyload NPS Series Handbuch

Anyload
Anyload EB300 Bedienungsanleitung

Anyload
Anyload OCS Series Bedienungsanleitung

Anyload
Anyload OCS-S Series Bedienungsanleitung

Anyload
Anyload EB100 Bedienungsanleitung

Anyload
Anyload ES-HA Series Bedienungsanleitung

Anyload
Anyload ES-HB Series Bedienungsanleitung

Anyload
Anyload OCS Series Bedienungsanleitung