3
Contents
Foreword................................................................................... 4
Intended Use............................................................................. 5
Safety Instructions .................................................................... 6
Preparations.............................................................................. 7
Parts Designation...................................................................... 8
Control Panel.......................................................................... 10
Hand Controls......................................................................... 11
Product Description/Functions................................................ 12
Drain control knob............................................................... 12
Fill function ......................................................................... 12
Auto fill function (option)...................................................... 12
Scalding protection.............................................................. 12
Temperature display............................................................ 12
Emergency stop .................................................................. 12
Shower handle .................................................................... 12
Functions lock .....................................................................14
Door lock............................................................................. 14
Air Spa™ (option)................................................................ 14
Sound & Vision® (option).....................................................14
Disinfection unit (option)...................................................... 16
Battery back-up................................................................... 16
Head cushion, Back support cushions and Leg rest
(accessories).........................................................................16
Operating Instructions............................................................. 18
Fill the foot well with water .................................................. 18
Bathing the resident ............................................................ 18
Shower the resident ............................................................20
Air Spa................................................................................. 22
Sound & Vision.................................................................... 22
Ending the bathing cycle..................................................... 24
Disinfect bath after each resident........................................ 24
Using a Standing & Raising Aid with Parker® ........................ 26
Resident transfer from Sara 3000™ to Parker.................... 26
Using a Ceiling lift with Parker ................................................ 28
Resident transfer from a ceiling lift to Parker ...................... 28
Disinfection Instructions.......................................................... 30
Care and Preventive Maintenance.......................................... 44
Troubleshooting...................................................................... 50
Technical Specifications ......................................................... 52
Labels on the Parker............................................................... 56
Approvals and List Standards................................................. 58
Electromagnetic Compatibility................................................. 59
Parts and Accessories............................................................ 63
ArjoHuntleigh Addresses .............................................Last page

4
Foreword
Thank you for purchasing
ArjoHuntleigh Equipment.
Your Parker is part of a series of quality prod-
ucts designed especially for hospitals, nursing
homes and other health care uses.
We are dedicated to serving your needs and
providing the best products available along
with training that will bring your staff maxi-
mum benefit from every ArjoHuntleigh prod-
uct.
Please read this Instructions for
Use thoroughly!
Please read this Instructions for Use (IFU) in its
entirety before using your Parker bathing sys-
tem. Information in this IFU is crucial to the
proper operation and maintenance of the equip-
ment, will help protect your product, and ensure
that the equipment performs to your satisfaction.
Some of the information in this IFU is important
for your safety and must be read and understood
to help prevent possible injury.
ArjoHuntleigh strongly advise and warn that only
ArjoHuntleigh designed parts, which are
designed for the purpose, should be used on
equipment and devices supplied by Arjo-
Huntleigh, to avoid injuries or malfunctions
caused by the use of inadequate parts.
Unauthorized modifications on any Arjo-
Huntleigh equipment may affect its safety. Arjo-
Huntleigh will not be held responsible for any
accidents, incidents or lack of performance that
occur as a result of any unauthorized modifica-
tion to its products.
Service and Support
A service routine has to be done to your Parker
to ensure the safety and operating procedures of
your product. See chapter, Care and Preventive
Maintenance.
If you require further information, please contact
ArjoHuntleigh for comprehensive support and
service programs to maximize the long-term
safety, reliability and value of the product.
Contact ArjoHuntleigh for replacement parts.
Contact information appears on the last page of
this IFU.
Definition in this IFU:
Means:
Safety warning. Failure to understand and obey
this warning may result in injury to you or to oth-
ers.
Means:
Failure to follow these instructions may cause
damage to all or parts of the system.
Means:
This is important information for the correct use
of this system or equipment.
Means:
The name and address of the manufacturer.
WARNING
CAUTION
NOTE

5
Intended Use
This equipment must be used in accor-
dance with these safety instructions.
Anyone using this equipment must also
have read and understood the instruc-
tions in this Instructions for Use (IFU).
If there is anything you do not com-
pletely understand, ask your ArjoHunt-
leigh representative.
This bath is intended for assisted bathing and
showering of adult residents in care facilities
(excluding use at home).
Parker must be used by appropriately trained
caregivers with adequate knowledge of the care
environment, its common practices and proce-
dures, and in accordance with the guidelines in
the Instructions for Use (IFU).
Any other use is prohibited. The bath should
only be used for the purpose specified here.
Resident assessment
We recommend that facilities establish regular
assessment routines.
Caregivers should assess each resident according
to the following criteria prior to use:
• Theresident'sweightshouldnotexceed 210
kg / 463 lbs (Max Patient Weight).
• Activeandsemi-activeresidents(i.e.ableto
sit upright self supported on the side of a
bed or toilet) can use the bath. Correct
transfer equipment shall be used, if needed.
• Residents with no capacity to support them
selves at all (i.e. able to sit upright with sup-
port) can use the bath, only with a ceiling
and a 2-point spreader bar with loop sling
for transfer and bath.
• The resident should have the ability to
understand and respond to instructions, or
have limited physical capacity to move, to
ensure a safe position during the bathing
procedure.
If a resident does not meet these criteria an alter-
native equipment or system shall be used.
Indication for Use
To relieve pain and itching and as an aid in the
healing process of inflamed and traumatized tis-
sue, and it serves as a setting for removal of
contaminated tissue.
Installation & Service
requirements
The Parker must be installed by appropriately
trained personnel according to the Assembly and
Installation Instructions, requirements in the
Assembly and Installation Instructions can only
be superseded by local code.
The expected life of this equipment, unless other-
wise stated, is ten (10) years, subject to preven-
tive maintenance being carried out in accordance
with the instructions for Care and Preventative
Maintenance found in this IFU.

6
Safety Instructions
WARNING
To avoid injury to both resident and
caregiver, never modify the equip-
ment or use incompatible parts.
WARNING
To avoid explosion or fire, never use
the equipment in oxygen rich environ-
ment, in presence of heat source or
flammable anaesthetic gases.
WARNING
To avoid electric shock, never use
other electrical equipment near this
device.
WARNING
To avoid injury, ensure that the resi-
dent is not left unattended at any time.

7
Preparations
Site preparations
Prior to installation of Parker bath the
floor and walls within the required area
must be finished.
Material: The floor should be made of a slip-
resistant material, free of bumps.
Floor Slope: When using a floor drain, the
slope towards the drain should not exceed 1:50.
Floor attachments: The floor construction
must be suitable for anchoring the bolts
•
Actions before first use
1 Visually check the package for damage. If
the product looks damaged due to freight,
make a complaint to the transport agency.
2 The packaging should be recycled accord-
ing to local regulations.
3 Install the Parker by qualified personnel.
See Assembly and Installation Instructions.
4 Check that all parts of the product are sup-
plied. Compare with the Parts Designation
page in this IFU. If any part is missing or
damaged - do NOT use the product.
5 Unpack the hand control(s) from the plastic.
6 Read the IFU.
7 Disinfect the product according to the
Disinfection Instructions in this IFU.
8 Perform a functionality test. See Care and
Preventive Maintenance.
9 Choose a designated area, where the IFU
should be kept and is easily accessible at all
times.
Make sure the Parker thermostatic mixer
has been calibrated according to the Assem-
bly and Installation Instructions by quali-
fied personnel or an ArjoHuntleigh
technician.
11 Make sure to have a rescue plan ready in
case of a resident emergency.
12 If you have any questions, please contact
your local ArjoHuntleigh representative for
support and service. The contact numbers
appear on the last page of this IFU.
Actions before every use
1 Checkthat all partsare in place.Compare to
the Parts Designation.
2 If any part is missing or damaged - do NOT
use the product.
10 WARNING
To prevent scalding, make sure
that the water mixer has been cali-
brated. Confirm that responsible
organization has established cali-
bration routines.
3WARNING
To prevent cross-contamination,
always follow the disinfection
instructions in this Instructions for
Use.

8
Parts Designation
1 Trigger handle
2 Lock button
3 USB connection
(with Sound & Vision option)
4 USB memory stick
(with Sound & Vision option)
5 Disinfectant flowmeter
(with Disinfection option)
6 Sound & Vision hand control
(with Sound & Vision option)
7 Disinfection spray handle
(with Disinfection option)
8 Door lock handle
9 Shower stand (for GB only)
10 Filling spout
11 Shower holder / shower handle
12 Emergency stop button
13 Grab handle
14 Hand control
15 Cover
(with Disinfection and/or Sound & Vision
option)
16 Control panel
17 Door hinge
18 Sound & Vision light
(with Sound & Vision option)
19 Water sensory knobs (3 knobs)
20 Drain
21 Drain control knob with built-in surface
overflow outlet
22 Disinfectant/Rinsing Inlet
(with Air Spa option)
23 Tub
24 Air Spa outlets (9)
(with Air Spa option)
25 Height adjustable feet
26 Compartment for disinfectant bottle
(with Disinfection option)
27 Sound & Vision speakers
(with Sound & Vision option)
28 Disinfection suction part
(with Disinfection option)
29 Disinfectant bottle (3 litre)
(with Disinfection option)
30 Lock keys for disinfectant compartment
(with Disinfection option)
31 Head cushion (Accessory)
32 Back support cushions (Accessory)
33 Leg rest (Accessory)
Type B Applied part.
Degree of Protection -
Electrical shock

9
2
19
24
26
25
16
17 21 22
10 12
11
9
13
8
20
18
23
M X
8
7
6
5
2
14
15
4
1
6
3
7
5
33
32
31
30
29
28
27

10
Control Panel
Parker
1 LED for shower indication
2 Filling water and Shower temperature dis-
play with scalding protection
3 Bath water temperature display with
scalding protection.
4 LED, lock function indicator
5 Mixing gradient
6 LED, ON/OFF disinfectant indicator
(option)
7 Disinfection ON/OFF
(option)
8 Fill ON/OFF
(Auto fill option)
9 Shower ON/OFF
10 Air Spa - whole tub ON/ Intensity/OFF
(option)
11 Air Spa - foot well ON/ Intensity/OFF
(option)
12 Function lock ON/OFF
13 Knob for water temperature adjustment
14 LED, battery back-up indicator
15 LED, mains indicator
7
5
43
8912
2
14 1513
1
11
6
10
Inhaltsverzeichnis
Andere ARJO HUNTLEIGH Badewanne Handbücher
Beliebte Badewanne Handbücher anderer Marken

Lyons
Lyons Elite ETLxx663219 Series Bedienungsanleitung

Woodbridge
Woodbridge BJ500 Montageanleitung

Whirlpool
Whirlpool Ariel ARL-702 Bedienungsanleitung

TEIKO
TEIKO EXCELLENT DUO Bedienungsanleitung

American Standard
American Standard Colony 5-1/2' x 32" Bedienungsanleitung

American Standard
American Standard 3052OD.X0X Kurzanleitung