AROHA CS11 Bedienungsanleitung

EN / NL / DE / FR / IT / ES
Combination smoke and CO detector
Aroha CS11

Alarm volume >85dBa
Silence mode
10 years, not replaceable
1008
Comply to Standard EN14604:2005/AC:2008 and EN50291-1:2018
CAUTION:
1. Before mounting the device, please active the alarm first.
2. Please test the alarm at least once a month.
Manufactured by: Invision Retail
Postbus 135
4900AC Oosterhout, The Netherlands

Product profile
Package content

Figure 1: Application

Figure 2 & 3: Installation

EN Thank you for purchasing our combination smoke and CO alarm device. Please
read this manual carefully to ensure proper use and store it in a safe place for future
reference.
Product specifications
Power: 3VDC
Battery Package: CR123A, Lithium Battery,1600mAh(Included)
Operation Current: <30uA (standby); <70mA (alarm)
Alarm Volume: >85 dB(A) at 3 meters
Smoke Sensitivity: 0.09 - 0.17 dB/m
CO sensor: Electrochemical sensor
CO Sensitivity: 50ppm 60~90min
100ppm 10~40min
300ppm 1~3min
Operating Temperature: -10°C to 40°C
Humidity Range: 15%-95% R.H.(Non-condensing)
Silence Time: Approx. 10 minutes
Complies to Standard EN14604:2005/AC:2008(Smoke) and EN50291-1:2018(CO)
Packing list
1 × Combination smoke and CO detector
1 × Mounting bracket
1 × Screw kit
1 × User manual
Installation instructions
•Check figure 1, 2 and 3 for correct installation locations.
•Smoke, heat and burning things will spread horizontally after rising to the ceiling, so install

the alarm in middle of the ceiling.
•If the length of the room or the hall is beyond 10 meters, you need to install multiple
alarms.
•In rooms with a combustion appliance place the detector at a horizontal distance between
1-3 meters from the CO source;
•Avoid existing air inlets or outlets and other objects on the ceiling;
•Avoid locations behind objects such as curtains and cupboards.
Don’t install on these locations
•High-humidity areas such as kitchens and bathrooms.
•Next to air outlets, fans and central heating.
•Dusty, dirty areas or areas with insects.
•High-temperature and easily polluted places.
•Places with difficult access, making it difficult to operate the test function.
•Within 1.5 meters from lamps.
•Next to doors or windows.
•In the top of rooms with sloping roofs, the corner of the room or other dead-air spaces.
Mounting the detector
•Twist off the mounting bracket from the detector.
•Put the bracket on the installation position and mark the 2 screw holes.
•Drill two 5mm mounting holes and insert two plastic anchor plugs by hammer.
•Screw the mounting bracket to the ceiling or the wall.
•Attach the detector to the mounting bracket and turn clockwise to lock the device.
CAUTION
•The installation instructions must be followed strictly to avoid unsafe conditions.
•Do not paint your detector.
•The battery cannot be replaced; do not try to replace the battery.

Activate and deactivate
The device is deactivated by default before leaving the factory. Before the device can be
used normally, the product must be activated. Flip the switch on the backside to the “ON”
position. To store the unit the switch can be set back to the “OFF”position. The unit also
activates automatically if it is attached to its baseplate.
Test your detector
Test the unit to ensure proper operation by pressing the cover. The alarm will sound if the
unit is working well. If there is no sound, refer to the “Trouble shooting” section.
CAUTION:
•DO NOT test your detector using an open flame. This may damage the alarm or ignite
combustible materials and start a structural fire.
•DO NOT stand close to the detector when the alarm is sounding. Exposure at close
range may be harmful to your ears.
•Test this detector once a month.
Alarm
If an alarm signal sounds immediately move to fresh air and do not re-enter the building
until it has been aired out and your alarm returns to its normal condition. Investigate the
source of the alarm and repair the defect. NEVER IGNORE ANY ALARM, while you can
see smoke, carbon monoxide is invisible and can be deadly.
Silence mode
When the detector is going off you can push the test button to pause it for approx. 10
minutes. During this silence mode the red LED will flash once every 8 second. The silence
feature is only to be used when the source of the alarm is known and safe. The detector will
automatically reset after approximately 10 minutes.
CAUTION: Before using the detectors silence mode, identify the source of the alarm

and be certain a safe condition exists. If the source is unknown, it should be assumed
that the alarm is due to dangerous levels of carbon monoxide.
Maintenance and cleaning
There are a few simple steps you need do to keep it working properly:
•Test the detector once a month.
•Do not paint the detector. Paint will seal the vents and interfere with the sensors.
•Never attempt to disassemble the detector to clean inside. This will damage the alarm.
•Clean the detector at least once a month to remove dust, dirt or debris. Use a vacuum
cleaner with a soft brush and vacuum all sides and covers of the detector.
Some materials, vapours or gases, can affect the reliability of the alarms in the short or
long term. The following is a list of substances that at high levels can damage the sensor or
cause temporary readings that are not CO readings: Ethylene, ethanol, alcohol, iso-
propanol, benzene, toluene, ethylacetate, hydrogen, hydrogen sulfide and sulfur dioxide.
Also most aerosol sprays, alcohol based products, paint, thinner, solvent, adhesive, hair
spray, after shave, perfume, auto exhaust (cold start) and some cleaning agents.
LED indicators
Mode
LED
Audible alarm(beeps)
Power on
Red/Orange/Green 1x
1x
Standby, no alarm
Green 1x every 56sec
None
Smoke alarm
Red 3x every 3 sec
3x every 3 sec
CO alarm
Red 4x every 4 sec
4x every 4 sec
Test
Red 3x long,4x quick 2 times
3x long, 4x quick. 2 times
Silence
Red 1x every 8sec
None
Low battery
Orange 1x every 56sec
1x every 56sec
Faulty
Orange 2x every 40sec
2x every 40sec

End of Life
Orange 3x every 56sec
3x every 56sec
Trouble shooting
Warranty information
Each detector has to be free from defects in material and workmanship under normal use
and service for a period of 2 years from the date of purchase. During the specified warranty
period, we will repair or replace any defective detector that is returned. Please contact us
at info@invisionretail.nl and include your name, address, phone number and order number
along with a brief description of what is wrong with the unit. Damage from neglect, abuse
or failure to adhere to any of the enclosed instructions will result in termination of the
warranty, and the unit will not be replaced or repaired. The manufacturer shall have no
liability for any personal injury, property damage or any special, incidental, contingent or
consequential damage of any kind resulting from gas leakage, smoke, fire or explosion.
Problem
Solution
The alarm does not sound when
testing
Please check whether the switch is in the ON
position
Alarm beeps and flashes
See LED indicator chapter
Nuisance alarms triggered
intermittently or when residents
are cooking, taking showers,
etc.
•Press test button to put detector in silence mode.
•Clean the detector. Please refer to the
“maintenance and cleaning” section.
•Move the detector to a new location.