ARTHUR HOLM ERT Bedienungsanleitung

User Guide
Danish craftmanship
Mediterranean soul
Technology Serving Design
ERT
IP to RS422/RS485 interface control

TABLE OF CONTENTS
REGULATIONS AND SECURITY 5
SAFETY INSTRUCTIONS 5
SYSTEM DESCRIPTION 7
CONTROL AND CONNECTORS 10
SYSTEM CONFIGURATION 13
AHnet ADDRESS CONFIGURATION 18
AHnet PROTOCOL 20
INFORMATION ON DISPOSAL 24
WARRANTY TERMS AND CONDITIONS 25

WELCOME
Thank you for purchasing an ARTHUR HOLM product.
Please, read this installation and operating instructions carefully and keep
them in a safe place for future reference.
We remain at your entire disposal if you have any suggestions.
Henrik Holm
General Manager

ABOUT US
The Company
Arthur Holm has its origins in the Danish furniture designer Jorgen Alex
Jensen, who was active during the sixties and the seventies. His design
inspiration and his concept of ergonomics have been continued by his
family, the design force behind Arthur Holm product range. The result of
combining Scandinavian design tradition with Mediterranean creativity,
exibility and emotion is a wide product range built on more than 25 years
of craftsmanship.
Arthur Holm offers a professional product range where tomorrow’s
technology is shaped into valued materials with design exibility and
customisation, specially created to enhance communication and
collaboration in reception, conference and meeting areas.
The art of customisation
Arthur Holm offers a range of ingenious products whose designs are based
on quality materials and the latest technology. Products which endow
meeting and conference rooms with silent, ergonomic, innovative and
aesthetic solutions that integrate into the furniture, hang from the walls as
works of art or are used as interactive points of information.
The world of Arthur Holm
Arthur Holm offers a selection of unique, elegant, versatile, exible and
ergonomic products that are being used in meeting and conference
rooms, reception areas, auditoriums and public zones of leading
companies throughout the world.
The numbers speak for themselves! We currently own 33 product
patents,have presence in over 45 countries with products and solutions
inmore than 25,000 installations.
It will be our pleasure to work with you, designing your unique and
personalised environment. Our broadcast electronic engineers will
provide the latest technology while our design team will offer you the most
exclusive appearance.
Our team puts its heart, passion and pride in all our designs.

5
SAFETY INSTRUCTIONS
Plugs
• Do not dismantle any part of the device power connector.
• Disconnect the power plug from the AC outlet when the device is not
going to be used for an indenite period of time.
Power and extensions cords
• Use the appropriate power cord with the correct plug type.
• Do not overload wall outlets or power cords.
• Make sure the total ampere passed through an extension cord does not
exceed the maximum allowed by the cable used.
• Do not place anything on the power cord.
• Do not locate this product where a person may walk or trip over the
cord.
REGULATIONS AND SECURITY
ATTENTION: Do not disassemble or modify the device in any way.
This symbol warns of the presence of dangerous un-insulated
voltages inside some of the components, of sufcient magnitude
to expose people to risk of electronic shock.
This symbol draws attention to important use and maintenance
instructions in the manual that accompanies the unit.
This symbol indicates that the equipment conforms to the norms
established by the European Community.
This symbol indicates D.C. current.

6
Wiring connected to hazardous voltage requires installation by
qualied personnel or the use of ready-made exible cables.
For your security, your equipment must be connected to an
electrical outlet with grounding connection protection.
Since the plug is used to disconnect the device, the operating
electrical outlet must be in an easily accessible place.
Environment
• Install the equipment on an elevated, at surface.
• Install the equipment in a ventilated area.
• Avoid exposing the equipment to:
∙Rain or water
∙Excessive heat, cold or humidity
∙Area exposed to direct sunlight
∙Dirty areas
∙Equipment generating strong magnetic elds
• Avoid placing open containers of liquid, near the equipment.
• Keep a minimum distance of 30 mm in order to have good ventilation.
• Never place above the device any sources of ames such as lighted
candles, etc.
• If you are using the device in extreme weather conditions and/or
tropical climates, the equipment should be installed in a room which
ensures a reasonable level of temperature and humidity.
SAFETY INSTRUCTIONS

7
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV
technician for help.
SAFETY INSTRUCTIONS

8
SYSTEM DESCRIPTION
General
ERT interfaces provide an easy and convenient system to control and
diagnose motorised monitors, microphone lifts and other automated
solutions by Arthur Holm helping to reduce the installation costs in terms
of both equipments and time.
Easy to install and set-up, they facilitate a quicker installation and
eliminate the need of external relay boxes and extra power outlets. It
is also possible to have Arthur Holm’s virtual support on site as long as
there is an Internet connection available.
AHlink wireless control is also integrated in ERT interfaces, providing an
easy and direct access to the most common settings through an app
and making the start-up and future interventions hassle free. This means
there is no need to access physically the unit to set-up or diagnose its
installation.
Highlights
• OTAS (One Touch Addressing System)
• IP to RS422/RS485 interface
• ERT-60 2 AHnet inputs (RS-422) / ERT-30 1 AHnet input
• Controls up to 60 units (ERT-60)
• RDM system (Remote Diagnostic and Maintenance)
• Remote/local control and management
• Wireless control through AHlink app
Box Contents
Before the installation of your device please check the contents of the
shipping box, it must contain the following items:
• ERT unit
• Power cord
• Power supply 100-2 40Vac, 50-60Hz. Output 12V
• User guide

9
SYSTEM DESCRIPTION
Available Models
MODEL DESCRIPTION
ERT-30
IP to RS-422 interface to control, congure
and diagnose ARTHUR HOLM motorised
products. 1 AHnet port (RS422/ RS485) to
control up to 30 units. Ethernet RJ45. OTAS
(One Touch Addressing System).
Remote/local control and management.
RDM system (Remote Diagnostic and
Maintenance). Wireless control through
AHlink app.
ERT-60
IP to RS-422 interface to control, congure
and diagnose ARTHUR HOLM motorised
products. 2 AHnet ports (RS422/RS485) to
control up to 60 units. Ethernet RJ45. OTAS
(One Touch Addressing System).
Remote/local control and management.
RDM system (Remote Diagnostic and
Maintenance). Wireless control through
AHlink app.

10
CONTROL AND CONNECTORS
12V D.C.: Power input connector. Plug the power supply supplied.
SETUP: Eight deep switches to control and setup the unit.
DIP1: Activates the radio signal to control the unitP
using AHlink APPMMMMMMMMMMMMMMMMML
DIP2:JActivates the automatic AHnet ID
YUIHHHHHHHHHHHHHHHHconguration on the RS422 bus
DIP3: Not used
DIP4: Activates the rmware upgrade
DIP5: Not used
DIP6: Congures the factory IP address
IP: 192.168.0.128
MASK: 255.255.255.0
GATEWAY: 192.168.0.3
MAC: 70:B3:D5:49:70:00
DIP7: Not used
DIP8: Not used