Avere FXT 5000 Series Bedienungsanleitung

FXT 5000 Series Installation Guide
Avere Systems, Inc.
Apr 05, 2018
www.averesystems.com
Part number 0456-004-0171, rev E (electronic version)
Part number 0456-004-0191, rev E (printed version)


CONTENTS
1 Introduction 1
1.1 Cautions and Warnings .......................................... 1
1.2 The FXT 5000 Series Platform ...................................... 1
1.3 Avere Documentation .......................................... 2
2 Product Specifications and Requirements 3
2.1 Dimensions and Specifications ...................................... 3
2.2 Power and Thermal Specifications .................................... 4
2.3 FXT 5000 Series Front and Rear Illustrations .............................. 6
2.4 Environmental Requirements ...................................... 8
3 Precautions for Product Use 9
3.1 Unpacking and Handling FXT Series Equipment ............................ 9
3.2 Electrical Considerations ......................................... 10
3.3 Racked FXT Series Nodes ........................................ 11
3.4 General Precautions ........................................... 12
3.5 Laser Radiation .............................................. 13
3.6 Thermal Considerations ......................................... 13
3.7 Electrostatic Discharge (ESD) Precautions ............................... 14
4 Installing an FXT 5000 Series Edge Filer Node in a Rack 15
4.1 Precautions ................................................ 15
4.2 Rack Installation ............................................. 16
4.3 Removing an FXT 5000 Series Node from a Rack ........................... 17
4.4 Installing and Removing the Front Bezel ................................ 18
5 Making Network Connections to the FXT 5000 Series Node 21
5.1 IP Address Requirements and Cluster Configuration .......................... 21
5.2 Physical Connections ........................................... 21
5.3 Connecting Network Cables ....................................... 22
5.4 Cable Guidelines ............................................. 24
5.5 Network Connections to the IPMI Port ................................. 26
5.6 Connecting to the Serial Port (if necessary) ............................... 27
6 Power Connections for the FXT 5000 Series Edge Filer 29
6.1 Connecting Power Cables ........................................ 29
6.2 Powering On an FXT 5000 Series Node ................................. 29
6.3 Powering Off an FXT 5000 Series Edge Filer Node ........................... 30
7 Monitoring the FXT 5000 Series Edge Filer 31
7.1 Monitoring System Health ........................................ 31
7.2 Status LEDs ............................................... 31
8 Regulatory Information for FXT 5000 Series Nodes 37
8.1 Electrical Safety ............................................. 37
8.2 Electromagnetic Compatibility ...................................... 37
8.3 Environmental Compliance ....................................... 38
i

9 EU Declaration of Conformity 39
10 Preparing a Node for Return to Avere Systems 41
11 Copyright and Trademark Information 43
11.1 Copyright Information .......................................... 43
11.2 Trademark Information .......................................... 43
11.3 Document Numbers ........................................... 43
ii

CHAPTER
ONE
INTRODUCTION
The FXT 5000 Series Installation Guide is written for system administrators who need to install and administer
Avere FXT Edge Filer hardware nodes in an Avere cluster. It assumes that you have a basic knowledge of networked
storage, including planning for and installing networked data storage components in a data center.
1.1 Cautions and Warnings
The following highlights are used in this document:
1.1.1 Precaution Statements Used in this Document
This document uses the following highlights to draw attention to potentially hazardous or undesirable situations:
A warning indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury.
A caution indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury.
A notice indicates information considered important, but not related to personal harm or injury.
1.2 The FXT 5000 Series Platform
The FXT 5000 Series platform describes a product line of servers, also called filers or nodes, that run the Avere OS
software.
Each model in the FXT 5000 Series contains and uses multiple types of storage media and high-speed Gigabit
Ethernet data ports (either 25GbE or 10GbE) to support high-bandwidth network traffic. FXT 5000 Series nodes
feature NVRAM to protect written data in the event of a power outage or other failure, and redundant power
supplies.
The table below shows the features for each server type.
1

FXT 5000 Series Installation Guide
1.2.1 FXT 5000 Series Specifications
FXT 5200 FXT 5400 FXT 5600 FXT 5850
CPU Cores 16 16 16 16
NVRAM (GB) 4 4 4 4
DRAM (GB) 128 256 384 768
Network Ports 4 10GbE,
4 1GbE
4 10GbE,
4 1GbE
4 10GbE,
4 1GbE
4 dual-rate 25GbE/10GbE,
4 1GbE
SAS HDD
Capacity
7.2 TB – – –
SAS SSD
Capacity
– 4.8 TB 9.6 TB 19.2 TB
Multiple Avere FXT Edge Filer nodes are configured together to provide an Avere cluster.
Note that the FXT 5000 Series is physically different from the FXT 4000 Series and other older Avere products.
Read Differences from FXT 4000 Series and Earlier Models (page 15) in the rack installation section section to
familiarize yourself with the changes before starting to set up an FXT 5000 Series node.
1.3 Avere Documentation
This document explains requirements and precautions for working with FXT 5000 Series hardware, and describes
how to install and set up FXT 5000 Series nodes. This document explains how to install a node in an equipment rack,
the type of network cables to use and how to install them, procedures for applying power and starting up or shutting
down a node, and information about using the chassis’s LED indicators to monitor status and troubleshoot a node.
After following the guidelines in this document, refer to the FXT Cluster Creation Guide
(http://library.averesystems.com/#fxt_cluster) for the software configuration steps to create an Avere cluster
from the hardware nodes you’ve installed.
Here is a quick reference list of other documentation you might find useful in addition to this FXT 5000 Series
Installation Guide. Click the links to visit the http://library.averesystems.com website, where you can download PDF
documents or view online information.
•FXT Cluster Creation Guide (http://library.averesystems.com/#fxt_cluster) - How to create and do the initial
configuration for a production Avere cluster. The cluster creation guide covers the next step after installing and
cabling the hardware according to the instructions in this guide.
•Configuration Guide (http://library.averesystems.com/#operations) - How to configure and administer your
Avere cluster
•Avere Control Panel Dashboard Guide (http://library.averesystems.com/#operations) - How to monitor the
status of your cluster from the Avere Control Panel
•Release Notes (http://library.averesystems.com/#release_notes) - Information about periodic Avere OS
software updates
•FXT 5000 Series Field Service Guide (http://library.averesystems.com/#service) - A technician’s guide to
servicing replaceable parts in the FXT hardware
Additional documentation may be available online - visit http://library.averesystems.com for the most recent
publications.
2 Chapter 1. Introduction

CHAPTER
TWO
PRODUCT SPECIFICATIONS AND REQUIREMENTS
This section gives product specifications and describes requirements for installing and using FXT 5000 Series nodes.
2.1 Dimensions and Specifications
These dimensions apply to each of the FXT 5000 Series models.
2.1.1 FXT 5000 Series Modular Dimensions
Modular Dimensions
The FXT 5000 Series is designed to fit in a standard equipment rack and is one rack unit high.
Height 1U (1.75 inches, 44.5 mm, nominal EIA standard)
Width 19 inches (482.6 mm, nominal EIA standard)
2.1.2 FXT 5000 Series Actual Dimensions
Actual Dimensions
Height 1.7 inches (43 mm)
Width (rack ears) 19.1 inches (485 mm)
Width (main enclosure with slide rails attached) 17.6 inches (447 mm)
Depth (rack ears to main enclosure rear) 27.9 inches (709 mm)
Depth (rack ears to furthest rear protrusion) 28.2 inches (716 mm)
Depth (rack ears to furthest front protrusion, without bezel) 0.9 inches (23 mm)
Depth (rack ears to furthest front protrusion, with bezel) 2.5 inches (64 mm)
2.1.3 FXT 5000 Series Weight
Weight
Gross Weight (includes all packaging) 48 pounds (21.8 kg)
Net Weight (without packaging, including accessories) 39 pounds (17.7 kg)
Node Weight (without packaging, without accessories) 33 pounds (15.0 kg)
3

FXT 5000 Series Installation Guide
2.2 Power and Thermal Specifications
FXT 5000 Series nodes use variable speed fans, so power depends on temperature. Maximum fan speeds are unlikely
to occur even at the highest specified ambient temperature (35° C/95° F). Power and thermal specifications are for a
system using 1+1 redundant power supplies, both supplying power.
2.2.1 FXT Series Nameplate Ratings
Nameplate Ratings for FXT 5000 Series Models
100 - 240 V ac
60 - 50 Hz
9.5 - 4.5 A
2.2.2 FXT 5850 Power and Thermal Measurements
FXT 5850 power at room temperature or at maximum fan speed
FXT 5850 At 22° C (71.6° F) Inlet Temperature At Maximum Fan Speeds
Voltage (V) 100 120 208 230 240 100 120 208 230 240
Frequency (Hz) 60 60 60 50 50 60 60 60 50 50
Current (A) 2.89 2.39 1.41 1.29 1.24 3.57 2.94 1.73 1.57 1.51
Apparent Power (VA) 289 287 293 297 298 357 353 360 361 362
Power Factor 0.99 0.99 0.95 0.95 0.95 0.99 0.99 0.96 0.96 0.96
Real Power (W) 286 284 279 282 283 353 349 345 347 348
Thermal Dissipation
(BTU/Hr)
976 969 951 962 965 1206 1192 1179 1183 1187
2.2.3 FXT 5600 Power and Thermal Measurements
FXT 5600 power at room temperature or at maximum fan speed
FXT 5600 At 22° C (71.6° F) Inlet Temperature At Maximum Fan Speeds
Voltage (V) 100 120 208 230 240 100 120 208 230 240
Frequency (Hz) 60 60 60 50 50 60 60 60 50 50
Current (A) 2.56 2.12 1.30 1.17 1.12 3.29 2.73 1.63 1.46 1.41
Apparent Power (VA) 256 255 270 269 268 329 328 339 336 338
Power Factor 0.99 0.99 0.94 0.93 0.93 0.99 0.99 0.96 0.96 0.95
Real Power (W) 254 252 253 250 249 326 324 325 322 321
Thermal Dissipation
(BTU/Hr)
866 861 865 854 851 1111 1107 1111 1100 1097
4 Chapter 2. Product Specifications and Requirements

FXT 5000 Series Installation Guide
2.2.4 FXT 5400 Power and Thermal Measurements
FXT 5400 power at room temperature or at maximum fan speed
FXT 5400 At 22° C (71.6° F) Inlet Temperature At Maximum Fan Speeds
Voltage (V) 100 120 208 230 240 100 120 208 230 240
Frequency (Hz) 60 60 60 50 50 60 60 60 50 50
Current (A) 2.48 2.06 1.22 1.11 1.06 3.21 2.67 1.56 1.40 1.35
Apparent Power (VA) 248 248 255 255 254 321 320 324 322 324
Power Factor 0.99 0.99 0.94 0.93 0.93 0.99 0.99 0.96 0.96 0.95
Real Power (W) 246 245 240 237 236 318 317 312 309 308
Thermal Dissipation
(BTU/Hr)
839 837 817 809 805 1084 1082 1063 1055 1050
2.2.5 FXT 5200 Power and Thermal Measurements
FXT 5200 power at room temperature or at maximum fan speed
FXT 5200 At 22° C (71.6° F) Inlet Temperature At Maximum Fan Speeds
Voltage (V) 100 120 208 230 240 100 120 208 230 240
Frequency (Hz) 60 60 60 50 50 60 60 60 50 50
Current (A) 2.52 2.09 1.24 1.15 1.10 3.21 2.70 1.59 1.43 1.37
Apparent Power (VA) 252 251 258 265 264 321 324 331 329 329
Power Factor 0.99 0.99 0.94 0.93 0.93 0.99 0.99 0.96 0.96 0.95
Real Power (W) 249 248 242 246 246 318 321 317 316 312
Thermal Dissipation
(BTU/Hr)
851 847 827 839 838 1084 1094 1083 1077 1066
2.2. Power and Thermal Specifications 5

FXT 5000 Series Installation Guide
2.3 FXT 5000 Series Front and Rear Illustrations
These diagrams show the front and rear layouts of FXT 5000 Series nodes. Front views are shown without the
optional bezel.
2.3.1 FXT 5850 Front Illustration
2.3.2 FXT 5600 Front Illustration
2.3.3 FXT 5400 Front Illustration
6 Chapter 2. Product Specifications and Requirements
Andere Handbücher für FXT 5000 Series
1
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Avere Server Handbücher
Beliebte Server Handbücher anderer Marken

iRobo
iRobo IPC2U Bedienungsanleitung

Nortel
Nortel 1000 Con?guration guide Bedienungsanleitung

Asus
Asus AP7500 Bedienungs- und Wartungshandbuch

Avid Technology
Avid Technology AirSpeed 5000 Bedienungsanleitung

HP
HP Integrity rx2600 Installationsanleitung

Milestone
Milestone Husky IVO 350T Bedienungsanleitung












