VALVE TIMER HKEY


INDEX
1.0 Intro
2.0 KEY: Turning on/off
3.0 Main menus
3.1 Device information menu
3.2 Program menu
3.3 BASE connection menu
4.0 Launch menu
4.1 Option 1) “BASE” manual mode
4.1.1 Valve manual activation and deactivation
4.2 Option 2) “BASE” automatic mode
4.2.1 “BASE” automatic mode (waiting for activation)
4.2.2 “BASE” automatic mode (activated)
4.3 Option 3) “BASE” low battery lock
5.0 BASE menu
5.1 Automatic mode menu
5.2 BASE set up menu
5.2.1 Display BASE program
5.2.2 Copy BASE program
5.2.3 Send BASE program
5.2.4 Change ID number on this BASE
5.2.5 Restore the BASE to factory settings
5.3 BASE: Turning on/off
5.4 Historical data management menu
04
05
06
06
08
10
11
11
11
12
12
13
13
14
14
15
15
15
16
16
17
17
17
ACMO-AVK | IOM Manuals
3
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

1.0 INTRO
The timer activates and deactivates a hydraulic valve at preset times. It is made up of two parts, a
“programming card” (hereinafter the KEY) and a “control unit” (hereinafter the BASE), which activates
the hydraulic valve through a solenoid.
The KEY is made up of a display and four buttons, it communicates with the BASE by radio signal at
short distances. A non-rechargeable battery feeds the two parts. The battery is sized to last ten years,
considering an ordinary use of the system. Timer information is available through the KEY. When the
KEY connects to the BASE wirelessly, it shows the state the BASE is in, it allows setting a new program,
activating /deactivating the valve manually, although not in program.
Here below an example of how to set up the BASE.
The example shows the duration and the time of the turns t1, t2, t3. The first turn starts at 10:00, lasts 2
h and 5 min, the second starts at 15:45, lasts 10 min, the third starts at 19:30, and lasts 45 min. No turns
are set on Saturday and Sunday, t2 is set on Monday, t3 on Tuesday and Wednesday, all turns (t1, t2 and
t3) are set on Thursday, and finally, t1 is set on Friday. There is the possibility to activate no turns/day, all
turns/day or a combination of the three turns/day.
Sun Mon Tue Wed Thu Fr Sa
0 2 3 3 + 1 0
t1 10:00 x 02:05
t2 15:45 x 00:10
t3 19:30 x 00:45
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK | IOM Manuals
4
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

2.0 KEY: TURNING ON/OFF
Press the OK / turn on button for 3 sec. to turn on the KEY.
Press the OK / turn on button for 3 sec. to turn off the KEY.
Note that the KEY turns off automatically after an inactivity time (presettable), calculated from the last use
of the buttons. When the device turns on, some information about the firmware appears.
After 3 seconds the main menu appears.
In case of low battery, the device informs the user it is necessary to replace the battery of the KEY.
Press the OK / turn on button to continue using the KEY, nevertheless, for a correct functioning, it is highly
recommended to replace the battery as soon as possible.
Functions of the KEY buttons:
• OK button: use it to enter, confirm, modify, memorize.
• ESC button: use it to exit, cancel, deny.
• Arrow button: use it to increase/decrease values, move from a menu to another.
LOW BATTERY
OK = CONTINUE
ACMO-AVK | IOM Manuals
5
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

3.0 MAIN MENUS
3.1 DEVICE INFORMATION MENU
Use the arrow button to scroll the menus; press the OK button to enter a menu. Press the ESC button to
exit a menu and return to its title. Now it is possible to scroll again the menus and choose another menu.
Enter the menu to visualize and/or modify the date and time of the KEY.
The “information menu” displays the date, the time and battery status of the KEY as per the following
example:
Press the OK button to modify the year using the arrow buttons, press again the OK button to modify the
month, repeat the operation to modify the day, the hour, and the minute until coming back to beginning
of the “device information menu”. The nn,nn value is the internal battery measurement expressed in Volt;
depending on the value recorded the display shows:
LEVEL: HIGH
LEVEL: MEDIUM
LEVEL: LOW
Press again the arrow button to visualize the card time zone with reference to the Coordinated Universal
Time (UTC). 00:00 indicates the time zone of London.
Menu
INFORMATION
OK=ENTER
Information
Date: 21/03/16
Time: 09:45
Battery: nn,nnV
Level: HIGH
OK=MODIFY ESC=EXIT
Information
Time zone
UTC +00:00
OK=MODIFY ESC=EXIT
Press the OK button to change the time zone. Use the arrow button to select the desired time zone.
Press again the OK button to confirm and save the selected option.
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK | IOM Manuals
6
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

Press again the arrow button to display the card auto power off time:
Press the OK button to modify the time:
Press again the arrow button to display the buzzer status:
Press the OK button to enable or disable the buzzer:
Information
Auto power off
time
3 minutes
OK=MODIFY ESC=EXIT
3 minutes
Auto power off
Time modify
OK=SAVE ESC=EXIT
Information
Buzzer
ENABLED
OK=MODIFY ESC=EXIT
DISABLE
The buzzer ?
OK=YES ESC=NO
Information
FIRMWARE
v06.06 Lan: EN
ESC=EXIT
Information
Hardware W
v01.17 Type: O
Bootloader
v02.24
ESC=EXIT
Press the arrow button to discover the firmware and hardware version in the KEY:
ACMO-AVK | IOM Manuals
7
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

Menu
PROGRAM
OK=ENTER
Sun Mon Tue Wed Thu Fr Sa
0 2 3 3 + 1 0
t1 10:00 x 02:05
t2 15:45 x 00:10
t3 19:30 x 00:45
3.2 PROGRAM MENU
Enter the menu to display and modify the valve automatic program.
Press the OK button to select the program and display the automatic parameters to activate/deactivate the
valve. Below, an example of BASE programming:
Press the OK button to modify the match of turns and days of the week. Use the arrow button to choose
one or more turns. Press again the OK button to move to the following day until the last day of the week.
Press the down arrow button to enter the menus to change the three turns. Press the OK button to change
the starting time. Use the arrow button to modify the hour, then press the OK button to confirm and move
to the minutes. Use the arrow button to modify the minutes, then press the OK button to confirm and move
to the duration. Use the arrow button/OK button as above (hours and minutes). Press for the last time the
OK button to memorize the set values in this menu.
Program
t1 ACTIVATION
09:45 x 00:18
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK | IOM Manuals
8
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

A turn can last from a minimum of 1 minute to a maximum of 23 hours and 59 minutes.
After the last turn, press the down arrow button to move to the next menu:
Program
THRESHOLD FLOW
0,0 l/s
10% hysteresis
100 l/pulse
Press the OK button to modify the threshold flow, use the arrow buttons to set the value, and then press
the OK button to modify the hysteresis. Use the arrow buttons to set the value, and then press the OK
button to modify the pulse weight. Use the arrow buttons to set the value, and then press the OK button
to finish the programming and memorize the set values in this menu.
0.0 l/s means the threshold is disabled. The enabled threshold controls the flow rate only if the valve is
ACTIVE (automatic mode). If the flow rate exceeds the threshold, it DEACTIVATES the valve. The valve
ACTIVATES again once the flow rate falls below the threshold.
In case of instable flow rate, the adjustable hysteresis avoids activating or deactivating the valve
continually.
The pulse weight depends on the type of volume meter connected to the BASE. Program the pulse weight
according to the volume meter for a correct flow rate measure.
Press the down arrow button to enter the last menu and select the type of meter (ultrasonic/non-
ultrasonic).
Press the OK button to enable/disable the ultrasonic meter.
Press the OK button to confirm.
Program
Ultrasonic meter
DISABLED
ACMO-AVK | IOM Manuals
9
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309

3.3 BASE CONNECTION MENU
Enter the menu to connect to the BASE and operate on it.
Note: Start the BASE before operating on it, see chapter “BASE turning on/off”.
Press the OK button to start the radio-scan to detect the BASE.
The following message appears when no BASE is detected:
If the radio scan detects more than one BASE, use the arrow button to choose.
Press the OK button to connect.
When the KEY detects only one BASE, it connects to the BASE directly. No confirmation needed. The
following messages confirm if the connection is successful. The messages display the ID number of the
BASE connected to the KEY.
Once connected, it is possible to enter the first BASE menus.
Menu
CONNECTION
OK=ENTER
RADIO
SCAN
DEVICES
OUT OF RANGE
Choose one of
03 devices
OK=ENTER ESC=EXIT
Selected
01 BAS id:00051
>01 BAS id:00051
02 BAS id:00012
03 BAS id:00549
OK=EXEC ESC=EXIT
Base
Code: 00051
The designs, materials and specifications shown are subject to change without notice. This is due to the continuous development of our product programme.
Unauthorized use is forbidden.
ACMO-AVK | IOM Manuals
10
ACMO-AVK AUTOMATIC CONTROL VALVE SERIES 879
M117 VALVE TIMER HKEY - ver. 1.6
ACMO-AVK_IOM_valve-timer_M117_EN_02-20210309
Andere Handbücher für ACMO 879 Series
2
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis