Avonic AV-CON300-IP Bedienungsanleitung

www.avonic.eu
User Manual
Version 1.0
AV-CON300-IP
PTZ camera controller over IP and serial

2
www.avonic.eu 2
Contents
Introduction......................................................................................................................................................... 3
Congratulations. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3
Contact. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3
Join Avonic.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3
Safety Notes.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 3
Package contents........................................................................................................................................ 4
Contents. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 4
Product Overview......................................................................................................................................... 4
Features .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 4
Installation............................................................................................................................................................ 5
Connections. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 5
Serial Communication Control .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 7
VISCA network connection diagram.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8
RS485 network connection diagram. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8
IP network connection diagram. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 8
OSD Menu .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 9
Overview of Buttons .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 10
Menu Structure .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 11
Switch between serial and IP mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 15
Serial Mode Display.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 15
IP Mode Display .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 15
Control settings.. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 16
Create a custom IP address and assign it to a Channel Button . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 18
Reassign a [CH] Button IP shortcut after deletion of an IP address .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 18
Maintenance...................................................................................................................................................... 19
Controller Maintenance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 19
Unauthorized Use. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 19
Troubleshooting............................................................................................................................................. 19
General advise. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 19
Power Issues. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 19
IP functionality issues .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 20
Serial functionality issues. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. 20
Specications.................................................................................................................................................... 21

Thank you for your Avonic purchase. Before beginning to operate this device, please read the
manual in order to make sure the best performance is obtained. Save this manual for future
reference.
For any questions or suggestions, contact your reseller or the local distributor of
Avonic. Find the local distributor on the website of Avonic. For the most recent version
of the manual or datasheet, look at the Avonic website: www.avonic.eu
facebook.com/
avonicPTZ linkedin.com/
company/avonic/ twitter.com/
avonic
• InstallationandservicingshouldonlybedonebyQualiedServicePersonnel
and conform to all local codes.
• This unit is designed for indoor use only and it must not be installed where
exposed to water or other liquids and moisture.
• Before powering on the device, check the input power voltage carefully.
• Avoid shock and vibration when transporting and installing the device.
• Electronicdevices produce heat. Donot blockthe ventilationslots of thedevice
and make sure the installation environment is well ventilated to avoid
overheating.
• Before cleaning, unplug the power cable. Use a soft, damp cloth to clean the
device, do not use strong or abrasive detergent to clean that will damage the
device.
• If you wish to dispose this product, please contact Avonic to obtain info about
the disposal procedure.
3
www.avonic.eu 3
Join Avonic
Safety Notes
Contact
Congratulations
Introduction

www.avonic.eu 4
Quantity Description Avonic SKU
1 pc PTZ Camera Controller AV-CON300-IP
1 pc Power Supply 12V/2.5A AV-CON300-PSU
1 pc 5 way phoenix connector AV-PHOENIX-5
1 pc RJ45 to DIN-8 cable for RS232 AV-CON300-DIN
Contents
Package contents
The Avonic AV-CON300-IP is an advanced PTZ camera controller with serial and ip controlling
capabilities. With this controller it is possible to control up to 255 cameras and using up to 255
presets per camera.
The controller supports the Visca, Visca over IP, Pelco-D and Pelco-P protocol and can be
connected with standard RJ45 connnectors for easy integration . The Avonic AV-CON300-IP is
therefore compatible with all Avonic PTZ cameras as well with other brands that support these
protocols.
Switch easily between serial and ip control, auto and manual focus, save and load presets, and
connect multiple controllers to multiple cameras.
Product Overview
• Optical 3D joystick gives a comfortable pan / tilt / zoom operation.
• Control for camera OSD menu operation.
• VISCA protocol can be used to control up to 35 cameras over 5 channels. Over Pelco up
to 50 cameras, 10 per channel.
• VISCA over IP protocol can be used to control up to 255 cameras.
• PTZ and lens control speed can be adjusted through their respective control buttons.
Features

www.avonic.eu 5
1. Firmware upgrade connector (9-pin DSUB male)
2. Camera control channel CH1-CH5 (RJ45)
3. 5-pin Phoenix interface (only CH1)
4. Lan/Ethernet connection standard RJ45
5. 12V DC power supply connector
6. Power switch
Connections
Installation
RJ45 channels (CH1-CH5) Serial Control
The Avonic AV-CON300 comes with a single RS232 connecting cable with RJ45 plug to Mini
DIN-8 plug. With this cable only 1 channel can be connected to the controller. This channel
can control up to 7 (VISCA) or up to 10 (PELCO) cameras.
To control the cameras assigned to the other channels, more RJ45 cables are required. The
Mini DIN 8 connector is used for RS232. The RS485 requires only 2 wires and can often be
attached to a 2-pin Phoenix connector at the camera. The RJ45 pin-layout diagram is as
follows:

www.avonic.eu 6
RJ-45 Mini DIN-8

www.avonic.eu 7
RJ45 channels (CH1-CH5) Serial Control continued
The camera(s) assigned to channel 1 can also be controlled using the 5-pin Phoenix connector.
The connection diagram is as follows:
Function
1. RS422 (-)
2. RS422 (+)
3. GND (G)
4. RS485 (-)
5. RS485 (+)
COM port settings
In default working mode, an Avonic camera is able to connect to the Con300ip controller with
RS-232 or RS-485 serial interface.
The camera can be controlled via RS-232, the parameters of RS-232C are as follows:
• Baud rate: 2400/4800/9600/115200
• Start bit: 1 bit.
• Data bit: 8 bits.
• Stop bit: 1 bit.
• Parity bit: none.
The camera can be controlled via RS-485, Half-duplex mode. The parameters are:
• Baud rate: 2400/4800/9600
• Start bit: 1 bit.
• Data bit: 8 bits.
• Stop bit: 1 bit.
• Parity bit: none.
Serial Communication Control

www.avonic.eu 8
When connecting multiple cameras through RS-232, use daisy chaining network architecture. Max
cable length for RS-232 is 10-15m.
To connect multiple cameras by RS485, the cameras are attached to a 2-wire twisted pair bus (max
length 1200m) that is terminated at both ends with a 120 Ω impedance resistor. The maximum distance
from the bus to the camera or controller is 5m.
Connect an Avonic ip controller to a LAN using a standard lan switch.
Addressing is done via IP, the Visca address in a visca over ip environment is always 1.
VISCA network connection diagram
RS485 network connection diagram
IP network connection diagram
Controller
IP controller
Ethernet
Ethernet
Ethernet
(PoE) Switch
PC
Camera
In Out
RS-232 RS-232 RS-232
In Out In Out
Camera
Camera
Camera

www.avonic.eu 9
OSD Menu
Select Protocol 1. Net Channel
2. CH 1
3. CH 2
4. CH 3
5. CH 4
6. CH 5v
Visca over IP Manage Custom add. list of addresses
Add New Custom add. Compatible
Transport Protocol
Port Number
IP Address
Assign IP channels CH1 ~ CH5
Real-Time Refresh
Visca over Serial Compatible
Tally Connect
Tally Mode
Real Time Refresh
Ethernet DHCP
IP Address
Subnet Mask
Gateway
Serial Port Baud Rate CH1 ~ CH5
Instruction Repeater
Rocker PAN reverse
TILT reverse
Rocker Switch Correct
Buzzer ON/OFF
Sleep Time
Language
About Device
Reset Device
MENU

www.avonic.eu 10
1. 7. 20. 8.
2. 9.
10.
3. 11.
12.
4.
5. 19.
6.
13. 14. 15. 16. 17. 18.
1. Manual Iris Control 11. Toggle White Balance modes
2. Manual Brightness Control 12. CH1~CH5 select camera buttons
3. Auto Exposure 13. Reset preset position
4. Manual selection of camera 14. Auto focus ‘ON’ button
5. Set preset position of camera 15. Manual focus
6. Zoom in and out ‘rocker’ button 16. Control of PTZ speed
7. Toggle button between Net and Serial mode 17. Position Key [0~9]
8. Red gain 18. PTZ control joystick
9. Blue gain 19. Joystick button
10. Toggle menu on/off 20. Information Display
Overview of Buttons
Andere Handbücher für AV-CON300-IP
1
Inhaltsverzeichnis
Andere Avonic Controller Handbücher

Avonic
Avonic AV-CON300 Bedienungsanleitung

Avonic
Avonic AV-CON300 Bedienungsanleitung

Avonic
Avonic AV-CON300-IP Bedienungsanleitung

Avonic
Avonic CM-CON100 Bedienungsanleitung

Avonic
Avonic CD500 Bedienungsanleitung

Avonic
Avonic CM-CON100 Bedienungsanleitung

Avonic
Avonic CM-CON100 Bedienungsanleitung

Avonic
Avonic AV-CON100 Bedienungsanleitung

Avonic
Avonic CM-CON100 Bedienungsanleitung

Avonic
Avonic CM-CON100 Bedienungsanleitung