Baldor Modbus Plus Bedienungsanleitung

Modbus Plus
Expansion Board
Catalog No. EXB015A01
Installation and Operating Manual
8/03 MN1322

Table of Contents
Table of Contents i
Section 1
General Information 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limited Warranty 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Notice 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 2
Expansion Board Description 2-1. . . . . . . . . . . . . . . . . . . .
Section 3
Installation 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Board Installation 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Controls 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Expansion Board Installation 3-2. . . . . . . . . . . . . . . . . .
Dual Expansion Board Installation 3-4. . . . . . . . . . . . . . . . . . .
Section 4
Hardware Setup 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DIP Switch Settings 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable Connection 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerup 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LED Indicators 4-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Terminal Strip Connections 4-5. . . . . . . . . . . . . . . . . . . . .
Section 5
Register Map for Modbus Plus 5-1. . . . . . . . . . . . . . . . . . . .

ii Table of Contents

Section 1
General Information
General Information 1-1
Introduction
The Baldor controls represent the latest technology in microprocessor
based motor controls. In addition to the user programmable parameters
available in every control, many different expansion boards are available
from Baldor to further customize the control to most any application.
Expansion boards are categorized by compatibility into two groups:
Group 1 and Group 2, see Table 1-1. A board from either group may be
used alone in a control. If two boards are to be used, one board must
be from Group 1 and the other from Group 2.
Note: Using two Group 1 or two Group 2 boards in the same control is
not allowed.
Table 1-1 Group 1 and Group 2 Board Categories
Group 1 Board Name Catalog No. Manual No.
Isolated Input EXB003A0X MN1314
Master Pulse Reference/
Isolated Pulse Follower EXB005A0X MN1312
DC Tachometer Interface EXB006A0X MN1311
Isolated Encoder EXB008A0X MN1317
Resolver to Digital Interface EXB009A0X MN1313
Group 2 Board Name
RS-232 Serial EXB001A0X MN1310
RS-422/RS-485 Serial EXB002A0X MN1310
RS-232/485 Serial EXB012A0X MN1310
Four Output Relays/3-15 PSI
Pneumatic EXB004A0X MN1315
High Resolution Analog I/O EXB007A0X MN1316
2 Isolated Analog Output/ 3 Relay
Output EXB010A0X MN1319
Device Net EXB013A0X MN1320
Profibus EXB014A0X MN1323
Modbus Plus EXB015A0X MN1322

1-2 General Information
Limited Warranty
For a period of two (2) years from the date of original purchase,
BALDOR will repair or replace without charge controls and
accessories which our examination proves to be defective in
material or workmanship. This warranty is valid if the unit has not
been tampered with by unauthorized persons, misused, abused, or
improperly installed and has been used in accordance with the
instructions and/or ratings supplied. This warranty is in lieu of any
other warranty or guarantee expressed or implied. BALDOR shall
not be held responsible for any expense (including installation and
removal), inconvenience, or consequential damage, including
injury to any person or property caused by items of our manufacture
or sale. (Some states do not allow exclusion or limitation of
incidental or consequential damages, so the above exclusion may
not apply.) In any event, BALDOR’s total liability, under all
circumstances, shall not exceed the full purchase price of the
control. Claims for purchase price refunds, repairs, or
replacements must be referred to BALDOR with all pertinent data
as to the defect, the date purchased, the task performed by the
control, and the problem encountered. No liability is assumed for
expendable items such as fuses.
Goods may be returned only with written notification including a
BALDOR Return Authorization Number and any return shipments
must be prepaid.

General Information 1-3
Safety Notice
This equipment contains voltages that may be as great as 1000 volts!
Electrical shock can cause serious or fatal injury. Only qualified
personnel should attempt the start-up procedure or troubleshoot this
equipment.
This equipment may be connected to other machines that have rotating
parts or parts that are driven by this equipment. Improper use can
cause serious or fatal injury. Only qualified personnel should attempt
the start-up procedure or troubleshoot this equipment.
PRECAUTIONS
WARNING: Do not touch any circuit board, power device or
electrical connection before you first ensure that power has
been disconnected and there is no high voltage present
from this equipment or other equipment to which it is
connected. Electrical shock can cause serious or fatal
injury. Only qualified personnel should attempt the start-up
procedure or troubleshoot this equipment.
WARNING: Be sure that you are completely familiar with the
safe operation of this equipment. This equipment may be
connected to other machines that have rotating parts or
parts that are controlled by this equipment. Improper use
can cause serious or fatal injury. Only qualified personnel
should attempt the start-up procedure or troubleshoot this
equipment.

1-4 General Information
WARNING: Be sure the system is properly grounded before
applying power. Do not apply AC power before you ensure
that all grounding instructions have been followed.
Electrical shock can cause serious or fatal injury.
WARNING: Do not remove cover for at least five (5) minutes
after AC power is disconnected to allow capacitors to
discharge. Dangerous voltages are present inside the
equipment. Electrical shock can cause serious or fatal
injury.
WARNING: Improper operation of control may cause violent
motion of the motor shaft and driven equipment. Be certain
that unexpected motor shaft movement will not cause injury
to personnel or damage to equipment. Peak torque of
several times the rated motor torque can occur during
control failure.
WARNING: Motor circuit may have high voltage present
whenever AC power is applied, even when motor is not
rotating. Electrical shock can cause serious or fatal injury.
Caution: To prevent equipment damage, be certain that the
electrical service is not capable of delivering more than the
maximum line short circuit current amperes listed in the
appropriate control manual, 230 VAC, 460 VAC or 575 VAC
maximum per control rating.

Section 2
Expansion Board Description
Description 2-1
Introduction
The Modbus Plus expansion board is a Group 2 expansion board. It
allows a Series H control to communicate as a node on the Modbus
Plus network. It has a DB9 connector to make connection to the network
simple.
Group 2 board
Modbus Plus Expansion Board
Catalog No. EXB015A01
A good resource document is the “Modicon Plus Network Planning and
Installation Guide”. Refer to that guide for planning your network and
details such as cable specifications etc.

2-2 Description

Section 3
Installation
Installation 3-1
Board Installation
This section describes the Expansion Board installation procedure.
Caution: Before you proceed, be sure to read and become
familiar with the safety precautions at the beginning of this
manual. Do not proceed if you are unsure of the safety
precautions described. If you have any questions, contact
BALDOR before you proceed.
1. Remove the expansion board from the shipping container.
2. Remove all packing material from the board.
Caution: Be sure all packing materials are removed from the
board. Conductive foam may be present on the connectors
to prevent static build up during shipping. This can prevent
proper circuit operation.
If you are installing only one board, refer to the “Single Expansion Board
Installation”procedure. If you are installing two expansion boards (or a
second board) refer to the “Dual Expansion Board Installation”
procedure.
Inhaltsverzeichnis
Andere Baldor Computerhardware Handbücher
Beliebte Computerhardware Handbücher anderer Marken

EMC2
EMC2 VNX Series Betriebsanleitung

Panasonic
Panasonic DV0PM20105 Bedienungsanleitung

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Bedienungsanleitung

Gigabyte
Gigabyte B660M DS3H AX DDR4 Bedienungsanleitung

Raidon
Raidon iT2300 Bedienungsanleitung

National Instruments
National Instruments PXI-8186 Bedienungsanleitung