Balluff BDD 750 S Series Bedienungsanleitung

Touch Display BDD 750-_S…
User’s Guide
English

www.balluff.com
The detailed operating manuals of all devices as well as the declarations of conformity can also be
downloaded from the Internet at www.balluff.com.
All contents included in this manual are protected by the terms of use and copyrights of
Balluff GmbH. Any reproduction, modification, usage or publication in other electronic and printed
media as well as in the internet requires prior written authorization by Balluff GmbH.

Table of content
1. Safety Instructions and Responsibility................................................... 4
1.1. General Safety Instructions....................................................................................... 4
1.2. Use according to the intended purpose................................................................. 4
1.3. Installation..................................................................................................................... 5
1.4. Cleaning, Maintenance and Service Notes........................................................... 5
2. Introduction..................................................................................................... 6
2.1. Operation mode........................................................................................................... 6
3. Electrical Connections................................................................................. 7
3.1. DC Power Supply........................................................................................................ 7
3.2. Auxiliary Voltage Output............................................................................................ 7
3.3. SSI-Inputs ..................................................................................................................... 8
3.4 Control Inputs............................................................................................................... 9
3.4. Relay-Output ................................................................................................................ 9
4. Display and touch screen ......................................................................... 10
4.1. Screen structure for parametrization .................................................................... 10
4.2. Screen structure in operation ................................................................................. 11
4.3. Error Message............................................................................................................ 12
5. Parameter / Overview-Menu Structure .................................................. 13
5.1. General Menu............................................................................................................. 15
5.2. SSI Properties............................................................................................................ 18
5.3. Preselection Values.................................................................................................. 21
5.4. Preselection 1 Menu................................................................................................. 22
5.5. Preselection 2 Menu................................................................................................. 25
5.6. Preselection 3 Menu................................................................................................. 26
5.7. Preselection 4 Menu................................................................................................. 27
5.8. Command Menu........................................................................................................ 28
5.9. Display Menu.............................................................................................................. 30
5.10. Linearization Menu.................................................................................................... 31
6. Appendix........................................................................................................ 32
6.1. Parameter / serial codes.......................................................................................... 32
6.2. Linearization............................................................................................................... 36
6.3. Reading SSI-Value ................................................................................................... 38
6.4. Internal processing and calculation of SSI data................................................. 39
6.5. Dimensions................................................................................................................. 41
6.6. Technical Specifications:......................................................................................... 42

4
1. Safety Instructions and Responsibility
1.1. General Safety Instructions
This operation manual is a significant component of the unit and includes important rules and
hints about the installation, function and usage. Non-observance can result in damage and/or
impairment of the functions to the unit or the machine or even in injury to persons using the
equipment!
Please read the following instructions carefully before operating the device and
observe all safety and warning instructions! Keep the manual for later use.
A pertinent qualification of the respective staff is a fundamental requirement in order to use
these manual. The unit must be installed, connected and put into operation by a qualified
electrician.
Liability exclusion: The manufacturer is not liable for personal injury and/or damage to
property and for consequential damage, due to incorrect handling, installation and operation.
Further claims, due to errors in the operation manual as well as misinterpretations are
excluded from liability.
In addition the manufacturer reserves the right to modify the hardware, software or operation
manual at any time and without prior notice. Therefore, there might be minor differences
between the unit and the descriptions in operation manual.
The raiser respectively positioner is exclusively responsible for the safety of the system and
equipment where the unit will be integrated.
During installation or maintenance all general and also all country- and application-specific
safety rules and standards must be observed.
If the device is used in processes, where a failure or faulty operation could damage the
system or injure persons, appropriate precautions to avoid such consequences must be
taken.
1.2. Use according to the intended purpose
The unit is intended exclusively for use in industrial machines, constructions and systems.
Non-conforming usage does not correspond to the provisions and lies within the sole
responsibility of the user. The manufacturer is not liable for damages which have arisen
through unsuitable and improper use.
Please note that device may only be installed in proper form and used in a technically perfect
condition (in accordance to the Technical Specifications). The device is not suitable for
operation in explosion-proof areas or areas which are excluded by the EN 61010-1 standard.
.

5
1.3. Installation
The device is only allowed to be installed and operated within the permissible temperature
range. Please ensure an adequate ventilation and avoid all direct contact between the device
and hot or aggressive gases and liquids.
Before installation or maintenance, the unit must be disconnected from all voltage-sources.
Further it must be ensured that no danger can arise by touching the disconnected voltage-
sources.
Devices which are supplied by AC-voltages must be connected exclusively by switches,
respectively circuit-breakers with the low voltage network. The switch or circuit-breaker must
be placed as near as possible to the device and further indicated as separator.
Incoming as well as outgoing wires and wires for extra low voltages (ELV) must be separated
from dangerous electrical cables (SELV circuits) by using a double resp. increased isolation.
All selected wires and isolations must be conform to the provided voltage- and temperature-
ranges. Further all country- and application-specific standards, which are relevant for
structure, form and quality of the wires, must be ensured. Indications about the permissible
wire cross-sections for wiring are described in the Technical Specifications.
Before first start-up it must be ensured that all connections and wires are firmly seated and
secured in the screw terminals. All (inclusively unused) terminals must be fastened by turning
the relevant screws clockwise up to the stop.
Overvoltage at the connections must be limited to values in accordance to the overvoltage
category II.
For placement, wiring, environmental conditions as well as shielding and
earthing/grounding of the supply lines the general standards of industrial automation
industry and the specific shielding instructions of the manufacturer are valid.
1.4. Cleaning, Maintenance and Service Notes
To clean the front of the unit please use only a slightly damp (not wet!), soft cloth. For the rear
no cleaning is necessary. For an unscheduled, individual cleaning of the rear the
maintenance staff or assembler is self-responsible.
During normal operation no maintenance is necessary. In case of unexpected problems,
failures or malfunctions the device must be shipped for back to the manufacturer for checking,
adjustment and reparation (if necessary). Unauthorized opening and repairing can have
negative effects or failures to the protection-measures of the unit.

6
2. Introduction
The SSI display device is designed for panel mounting. It is universally applicable, with its
intuitive operation and the extensive features.
2.1. Operation mode
All functions are can be configured in the parameter menu.
The device can be set to one of the following operation modes:
•MASTER
-The clock for the connected sensor is produced
-The both clock terminals (CLK, / CLK) are configured as outputs in this case
•SLAVE
-The clock for the encoder is generated by an external device (the SSI master).
-The both clock terminals (CLK, / CLK) are configured as inputs in this case

7
3. Electrical Connections
The terminal screws should be tightened with a slotted screwdriver (blade width 2mm).
3.1. DC Power Supply
The unit accepts DC supply from 18 to 30 V at the terminals 1 and 2. The power consumption
depends on the level of the supply voltage with approx. 100 mA and the additional current
required at the Auxiliary Voltage Output.
All GND terminals are internally interconnected.
3.2. Auxiliary Voltage Output
Terminal 3 and 4 provide an auxiliary output for supply of sensors and encoders.
The output voltage depends on the power supply.
The encoder voltage is approx. 1 V lower than the power supply voltage at terminal 1 and 2
and should be loaded with max. 250 mA.
The auxiliary voltages output is switchable from 24 VDC to 5 VDC.

8
3.3. SSI-Inputs
At Terminal 5, 6, 7 and 8, the connection is available for SSI signals. The basic settings must
be set in the menu SSI PROPERTIES.
Wiring for MODE Master:
Wiring for MODE Slave:

9
3.4 Control Inputs
The three control inputs at terminal 10, 11 and 12 have HTL PNP characteristics.
In the COMMAND MENU the programmable functions for the control inputs can be assigned.
Available functions are: reset the display value, display switching, locking the touch screen or
release the lock function of the control or relay outputs.
Wiring of the control inputs:
Unconnected PNP inputs are always “LOW” and unconnected NPN inputs are always “HIGH”.
All inputs are designed to receive impulses from electrical impulse sources.
Notice for mechanical switching contacts:
When exceptionally mechanical contacts are used, please connect an external capacitor
between GND (-) and the corresponding input (+). A capacity of 10 µF will reduce the input
frequency to
20 Hz and miscounting due to contact bouncing will be eliminated.
3.4. Relay-Output
Two relay outputs with potential-free changeover contacts are available at terminal 27, 28, 28,
30, 31 and 32. Switching conditions can be set in the PRESELECTION MENU. The switching
states are displayed (display with unit and status bar) as K1 and K4.
DC-switching capacity max 150 VAC/ max 2 A / 50 W
Wiring of the relay outputs

10
4. Display and touch screen
4.1. Screen structure for parametrization
The parameter menus and the parameters are described in chapter 5.
Start setup procedure:
To edit the parameters,
press the touchscreen for 3 seconds.
Menu selection:
Select the parameter menu via arrow buttons and
confirm with “OK”.
The menu selection can be terminated
with „C“.
Parameter selection:
Select the parameter via arrow buttons and
confirm with „OK“.
The parameter selection can be terminated with
„C“.
Parameter editing:
Edit the parameter via arrow button up and down,
shift cursor via left and right and save with „OK“.
The parameter editing can be terminated with „C“.
Parameter changes becomes active only after closing the menu
selection.
.