Band-it 240 PB Bedienungsanleitung

Introduction ........................................................................................................page 01
Safety precautions ......................................................................................................03
Mounting ......................................................................................................................05
Electrical connection......Main power..........................................................................
PCB layout .........................................................................09
Inputs...................................................................................10
Outputs................................................................................22
Status communication ...Front LEDs...........................................................................32
Audio ...................................................................................35
Event-log ......................................................................................................................37
Passwords ...................................................................................................................38
Control Box ................................................................................................................39
HY3-pack replacement ...............................................................................................41
Maintenance.................................................................................................................43
First aid .......................................................................................................................44
Schematic examples ...............................................45
Specifications ..............................................................................................................04
08
Frequently asked questions &
BANDIT 240PB Installation manual v.408
World leader in
active security
INSTALLATION MANUAL
ONTENTS
BANDIT 240PB
C
UK 230 VAC

BANDIT 240 PB v.408
Introduction - p. 1
INTRODUCTION
By selecting this device, you have acquired advanced active access-prevention technology.
With BANDIT we offer you an affordable system which guarantees operational reliability, top
performance and a discrete design.
More and more private and public buildings are being equipped with a protection system
against burglary. When armed, these systems detect a burglary attempt. The detection is
generally communicated by means of a siren and/or strobe or sometimes an automatic
phone call to an alarm control centre or police station. In real terms these notifications are
satisfying, but the subsequent human intervention often arrives more than 10 minutes
after the event! Burglars are aware of this and use this time to steal the most valuable
things and get away in time.
BANDIT offers a unique and active solution to this problem. For this system is totally capable
of filling a large office, store or other room, within a few seconds, with a non transparent fog.
This fog prevents persons from entering the room for at least 10 minutes after setting off the
alarm, since they cannot see a thing. The ejected fog has a soft mint smell (to avoid possible
fire interpretation by outsiders), it is colourless and leaves no traces. So the fog safely and
quickly disables the vision capabilities of unwanted visitors.
BANDIT is installed in those rooms that contain the most valuable objects; by doing so,
burglary damage is effectively limited to a strict minimum.
Advantages:
- Fills 1000 Ft³ (28 m³) of space per second of fog expulsion.
- Extremely compact and discrete design.
- A system free of maintenance with very high operational reliability (by lack of moving
components).
- The standard integrated “Power saver” and good thermal isolation, maintains a very
low energy consumption, between 30 and 40 W/h, depending on the adjusted fog
expulsion period.
- Continuous control of liquid level. When the level is too low to guarantee a full
expulsion period it will be shown by an LED and an electrical contact will occur. In this
case you’ll have to replace the internal HY-3 pack. The recognition and acceptance of
the new HY-3 pack (such as the resetting of the HY-3 shortage notification), occur
automatically. For recharging, the empty HY-3 pack has to be returned to your BANDIT
dealer.
- In case of interrupted power supply voltage (230 VAC), operation is guaranteed:
electronics ~24 hours, fog generator ~2 hours.
- The device is prepared through plug-in connectors, to be extended with a control box
and/or a wireless remote control.
- A powerful and flexible alarm central connection. With this the unit can be programmed
by means of a PC/laptop (Win95/98/2000/XP). This kind of programming facility offers
a comfortable and practically unlimited programming possibility.
- Includes a ‘real time clock’ and extended log for 1000 events, whereby every event is
documented with time and description of it. This electronic log is equipped with an
internal battery (10 years), in order to save all data in the event of a total power failure
occurs.

BANDIT 240 PB v.408
p. 2 - Introduction
- The internal failure check system constantly controls the perfect operation of:
- the internal power fuses and heat fuses
- the power voltage of the 13,2 volt battery
- the communication with the HY-3 pack
- the status of the inputs and outputs
- the temperature of the heat exchanger, the HY-3 pack, and the PCB environment.
- the presence of power supply voltage.
- the internal tamper circuit (anti-sabotage circuit).
- By means of a connecting cable (communication link) between a IBM compatible PC or laptop,
you will be able to read out the unit (settings, log and/or internal values). The required CD with the
Bandit Software can be requested for free at your local BANDIT dealer, or can be downloaded from
our web site www.bandit.be. This program runs with Win95, 98, 2000 as well as with XP and offers
a friendly Windows like users program.
It is advised to perform a yearly fog generator test. See also Maintenance, page 43.
Standards:
- Complies with European CE and EMC Standards.
- Complies with International Standard: IEC 839-1-3
- Approved by the Belgian Ministry of Internal Affairs
- Complies with the British Standard: BS 7939 : 1999
- Complies with the Dutch Standard of the NCP: IOE 03301-M and IQA 06901-M
- Complies with the French Standard of the CNPP: test report n°AI 040006
approval n° 2004-0001
- Complies with the Danish Standard of the F&P: class 1, AIA 212
registration n° 10.212-00418
Industrial property:
- BANDIT is a registered trade mark.
- HY-3 is a registered trade mark.
- The BANDIT fog generator process is internationally protected by several patents.
CText and drawings in this document are subjected to author protection.
Copyright: BANDIT NV, B-3660 Opglabbeek, Belgium.
Producer:
BANDIT nv./sa. H. R. Tongeren: 78.324
Nijverheidslaan 1547 : (32) 89 85 85 65
B-3660 Opglabbeek Fax : (32) 89 85 23 64
Belgium web : www.bandit.be
((

Safety precautions - p. 3
SAFETY PRECAUTIONS
Location:
- To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
- Install the device in such a way to allow a good airflow.
- Only install the appliance as described, i.e. In vertical position, with the text on the
front panel being readable from the floor. The maximum angle of inclination is 15° to
the front and 10° in all other directions.
- System malfunction is possible at ambient temperatures above 50°C. Keep the appliance
away from heat sources such as radiators, heating elements, stoves or other heat
producing devices.
- The appliance is unexpectedly heavy, ~62 Lbs (28 Kg). It needs to be fixed on a sufficiently
solid surface. Use sufficiently strong fixing materials, preferably our 240 floor or wall
mounting, which are very solid and reliable supports for your unit.
Electrical connection:
- This appliance only operates on 230 VAC / 50 - 60Hz (210-240 VAC) supply voltage with
grounding. Always check the voltage on the rear cover of the device.
- This device has a max. Peak consumption of 3.5 A / 230 VAC. Use only power cable and
grounding of minimum 1.5 mm² (preferably flexible with end splices). Use the strain
relief which is ~0.5 In. beneath the entrance of the power supply input.
- If you detect a strange smell or smoke, the appliance has to be switched off immediately
by turning the main supply fuse to “off”.
- In case of doubt, immediately contact your BANDIT dealer or manufacturer, mentioned on
the back cover of this manual.
- There are no repairable components inside the appliance. Leave all repairs to authorised
persons and/or the manufacturer.
- The PCB contains a heat sink. On all parts and areas beneath and around this cooling
plate, there are uninsulated “dangerous voltage” points. This “dangerous voltage” can
cause electrical shocks.
- For further connection instructions, see page 8.
Cleaning:
- Do not use volatile fluids, such as alcohol, thinner, petrol or spirit to clean the outside
of the appliance. Use a clean, damp cloth.
- The black front textile has to be cleaned with a vacuum cleaner with soft brush mouth (dust
signs). The frequency of cleaning depends on the quantity of dust present in the room to be
secured.
Fog ejection control:
- The ejection nozzle is normally about 5°C warmer than the temperature of the environment,
so not warm enough to get burned by. However during fog ejection and the first two minutes
after, this nozzle can reach a temperature up to 120°C . Avoid direct contact with the nozzle
after a fog ejection to prevent skin burns.
- A fog ejection test only should be performed when:
a) All persons in the surrounding area and fire safety personnel have been notified, and
b) There is nobody in the immediate surroundings and/or direction of ejection.
- During a fog ejection test, it is prohibited to look towards the direction of the ejection nozzle
from a distance less than 25 Ft (8 metres).
BANDIT 240 PB v.408

p. 4 - Specifications
SPECIFICATIONS
Descriptions:
- Dimensions:
- Weight:
- Max. Mains supply failure:
- Reaction time:
- Fog ejection image:
Fog generator:
- Fog ejection capacity:
- Fog ejection pressure:
- Maximum fog ejection period:
- Warm-up time:
- Max./min. Environmental temp.:
- Maximum heat loss:
- Heat exchange capacity:
- Nominal ejected droplet size:
HY-3 pack:
- HY-3 fluid contents:
- Nominal working pressure:
- Maximum allowed internal pressure:
- Construction material:
- Build-in electronics:
Electrical:
- Min./max mains power supply:
- Nominal 12 V low voltage:
- Max peak current at 230 VAC:
- Average power consumption:
- Capacity heating element:
- Inputs:
- Outputs:
- Current back-up:
- Power control:
- Electronics:
10.6 In. wide x 14.4 In. high x 10 In. deep.
62 Lbs (28 Kg).
Fog generator +2 hours and electronics +24 hours.
1 second between alarm signal and fog ejection.
Cone shaped straight ahead (optional), or
1000 Ft³ filling of space / second with 1 Ft. eye object.
230 PSI (1.6 Mpa).
18 seconds.
50 minutes from cold condition.
maximum 50°C / 120°F and minimum 0°C / 30°F.
40 W/hour.
18 kW/hour.
section 0,000016 In. / 0.004 mm (full aerosol).
1.4 litre (0.37 gal.).
230 PSI (1.6 Mpa).
870 PSI (6 Mpa).
rvs 304L and aluminum AlMgS1.
digital temperature sensor and analog/digital
E²prom memory level.
tamper switch and control LED.
integrated propellant-expulsion security
direct working 12 V NC valve.
210 to 240 VAC at 50 to 60 Hz.
13.1 V DC from 0 tot max. 500mA load.
3.5 Amps.
40 W/hour.
750 W.
all inputs are insulated by an opto-coupler.
all outputs are potential free relais contacts
12 V / 2 Ah (sealed lead acid battery).
Pulse width modulator (PWM) through zero-cross triac.
Flash micro-controller, Platina Pt1000 sensor converter,
time/date clock with back-up battery and 64K E²prom.
On board communication with HY-3 pack
On board communication: 6-way connector for
connection to "Control Box" and 5-way plug for
wireless remote control.
Serial communication with communication link
BANDIT 240 PB v.408
(R60 standard version)
60° wide coon

As a professional, you’ll have to consider properly, what would be the most effective place to
install the appliance. Here are some guidelines which can help you with your decision:
þ Logically, you’ll place the appliance so that the fog expulsion points in the direction of the
supposed burglary entrance or in the area which contains the most valuable objects.
Should this entrance provide a potential big air passage to outside (i.e. a garage door,
a glass frontage which is sensitive for break-in, etc.), You’ll have to prevent the ejection
nozzle being pointed in this direction to avoid the potential fog ejection to be blown
outside. In this case, you’ll have to point the nozzle towards a side wall to break the
ejection pressure. This way, the fog will “cloud out” and only a little amount of
fog will be blown directly to the outside.
þ Avoid the ejected fog forming a oneway trap. The ejected fog is supposed to form a
strong take-away reducing barrier. Burglars are not supposed to be caught.
Further, if there is a false alarm, the chance to catch innocent persons, is bigger than to
catch burglars in a real burglary!
þ Determine the place in such a way that the ejection nozzle does not point in the direction
of fragile objects. The powerful fog expulsion could blow down these objects.
þ There has to be a free passage area for the ejected fog, of at least 20 Ft. before it
bounces against a fog blocking obstacle, i.e. a front wall. The space of about 20 Ft. in
front of the ejection nozzle will be the first to be filled out with fog, and this within 2
seconds.
þ If there are already PIR-sensors installed in the
room to be guarded and you don’t want to take
any risks with false triggering because of fog
expulsion, you’ll have to replace these PIR’s
with combo-sensors (PIR/radar). If you have to
install a new installation, use combi-sensors for
volumetric detection in ereas where BANDIT is
installed. Radar never detects floating clouds,
most PIR’s do sporadically.
þ Make sure that no burglar can come near the
unit without being detected first by a sensor.
This sensor has to start a fog expulsion,
independently of an eventual entrance delay.
Mounting - p. 5
MOUNTING
The unit is packed in a cardboard box:
15.35 x 15.35 x 1.57 In. which contains:
- BANDIT 240 PB device.
- double sided warning sticker “Burglary...”
- this installation manual.
- "HY-3 grip" tool
Wall with
concealed
wiring or
groove
Ceiling
+ 2 . In
Appliance slightly
inclined forward ~ 5°,
maximum 15°
Keep a minimum of
1 Ft. of space at the
left hand side of the
unit,in order to open
the hatch to the
HY-3 pack.
BANDIT 240 PB v.408

þ Make sure the BANDIT is firmly secured to wall or floor, to prevent a burglar with prior
knowledge from throwing the unit quickly through a window.
Use an optional available BANDIT wallmounting to install the unit against a wall:
There are two kinds of wallmounting: flat or swivel. Use the re-usable mounting help
“Handy boy” to install the unit, as this tool carries the unit and makes it possible that any
person can install the device easily by himself.
- For wallmounting against a solid brick wall, use plugs and screws supplied within
- For wallmounting against a double plaster wall, use special metal plaster-plugs
available in any hardware store.
- For wallmounting against a single layer plaster wall: install the unit only in an inner
corner and order in addition an optional plaster inner corner support plate. Don’t install
the unit with a normal wallmounting against these kind of walls to avoid the device
falling on the floor after a while, due to its weight.
p. 6 - Mounting
þ For floor mounting, use BANDIT floor mounting. This floor mounting is screwed into the
floor or stuck to it with included double-sided adhesive tape. The device is installed at 2
In. (50 mm) off the floor to avoid possible damage due to cleaning tools or water.
Hidden mounting of the appliance
þ For installation into a closet, order the device with option /L. This unit is supplied with 4
rubber supports (feet), a 2 In. extended ejection nozzle (a standard closet door has a
thickness of approximately 3/4 In). and a heat resistant black door rosette (ejection
nozzle passage). This way you can hide the device and at the outside only the rosette
will be visible. Make sure you provide a ventilation grid above and beneath to avoid too
much rising of the temperature in the closet due to BANDIT ‘s heat loss. With an ambient
temperature above 50°C / 120°F, the unit will activate its technical output [Okout] and you
can expect damage on the internal lead battery.
F
BANDIT 240 PB v.408
Do not use any other rosette than the
one supplied with the unit. The supplied
rosette is made of a special heat and
steam resistant material. Fix the rosette
by using the special nut delivered with
it.
Hole drilled through
cabinet door
(hole saw dia. 2 In.)
Ejection nozzle, available
in R/60 or R/0 (straith) version
4 rubber feet
max. 1” (24 mm)
Black finish
rosette
Rosette
assembly nut
M50 x s. 1.5
Cabinet door
Cabinet schelf

p. 7 - Mounting
Mounting aid: handy boy.
This optional tool is used to install the device against a wall. It is attached with two pins to
the wall mounting and so it makes a solid shelf.
On this temporary shelf, BANDIT is wired and adjusted. After installation, the two pins
are pulled out, releasing the handy boy, so it can be used again in the next installation.
You’ll save yourself a lot of trouble to keep the device at a working height while connection
works are being performed.
Mounting more than one BANDIT 240 devices in one large room.
l
f
g
o
w
o
F
60 Ft.
115 Ft
Example of mounting in a shop of
6980 Ft². Fog image after 8 sec. of
fog expulsion.
l
f
g
o
o
w
F
33 Ft
60 Ft
Example of mounting in a shop of
1980 Ft². Fog image after 8 sec. of
fog expulsion.
The BANDIT 240 has a room filling capacity
of ~1000 Ft³ per second. This corresponds with
~100 Ft²/sec. The max. surface area which
can be secured with one device is equal to
the max. fog expulsion period = 18 s x 100 Ft²/s
which is 1800 Ft². For larger surfaces, such as:
large shops and office spaces, one has to
install more devices, one device each 1500 Ft²
with a normal ceiling height of 9 Ft. Install the units in such a way that the fog stream of one
device points next to, but not in the direction of the next unit. This way, there is a round stream
of fog throughout the entire place. This guarantees the fastest filling of the room.
While mounting, keep in mind to provide a free passage for the fog stream. After a while, the
store keeper has forgotten about the units and stacks boxes and displays right in front of the
fog ejector of the devices.
BANDIT 240 PB v.408

p. 8 - Connection to main power supply
ELECTRICAL CONNECTION
The BANDIT 240PB is equipped with simple and yet versatile interface. This version is only
programmable through PC or laptop using the communication link.
This unit is intended to be connected to an existing alarm system or be installed as a stand-alone
unit.
The build-in electronic system takes care of controlling and securing:
- the fog generator (3 x temperature + frequency control of valve).
- tamper switch of the rear cover, HY-3 pack hatch and optional connected "Control Box".
- control of front- and PCB LED, and internal siren.
- read out of inputs and jumper adjustments.
- control of tamper-, technical- and programmable outputs.
- control of internal battery, glass fuses and internal fan.
- digital and analogue communication with the HY-3 pack.
- serial communication with PC/laptop (com port)
The complete electrical system is accessible by removing the rear cover of BANDIT (unscrewing
4 x M4 cross head screw). The rear cover is tamper secured, so be sure that the unit is not in
guard mode and that the control room (optional) is warned.
Connection on the main power supply: on the left, beneath the PCB, you’ll find a
3 way terminal block with integrated main fuse. The PCB is marked with “230 VAC supply”.
Connect the left connector strip (N) to the mains neutral (blue or white wire), the middle one to
the green-yellow ground wire and the right connector (L) to the mains phase (black wire).
Switching phase and neutral has no effect to the function of BANDIT .
The unit is secured for mains failures and can be practically seen as an Ohmic power load.
Connect the power cable through the strain relief connector (~0.5 In. beneath the left entrance in
the metal back frame).
LN
Supply
230 VAC
Power supply
12 V
500 mA
+ -
Power supply glass fuse (5 x 20 mm)
F1 = 4 AT slow
- For complete PCB (printed circuit board) layout with description of connector strips, see page 9.
- For detailed description of
- For properties of the in and outputs, see page 10 through 31.
LED functions, see page 32 through 34.
- Preferably use a separate fuse, directly coming
from the main power supply or connect to
existing power circuit of installed controlling alarm
system (BANDIT has a peak current consumption
of 3.5 Amps. for each unit).
- For easy installing, use flexible connection wires
3 x 1.5 mm² with end splices.
BANDIT 240 PB v.206
F1 4AT

p.9 - PCB layout
PCB layout
BANDIT 240 PB v.408
LN
N
N
Prim. transfo
Sec. Transfo
Heater 750W
heatexchanger
230 VAC
Power supply
6.3AT
1.25AT
500mAT
F1 4AT
red
JMP
F2
F3
F4
Programmable
output n° 2
Programmable
output n° 1
Technical OK
output
Tamper loop
output [Tmpout]
Programmable
input n° 3
Programmable
input n° 4
Programmable
input n° 2
Programmable
input n° 1
12 VDC supply
(max. 500 mA)
Mains power supply
connection block with
integrated fuse (4 AT)
Mains power connecting
cable, min 1.5 mm²
12 V =
+ + + + + c c cc c c- - - - -
Supply Xin1 Xin2 Xin3 Xin4 Tmpout OKoutOKout Xout1 Xout2
X+ X+ X+ X+ Ta com com comnc nc ncnc nc ncno no nono no no
X- X- X- X- Tb
500 mA.
inputs: 12 V = / 10 mA. outputs: maximum 24 V / 1A.
Red
White
Green
Blue
Yellow
Black
6 x Control box
PCB connector
Remote control
PCB-connector
Real Time
Clock
click-on
battery
Yellow PWM
heating
Led
Non-touchable mains
voltage zone
Rear cover tamper
spring switch
Andere Handbücher für 240 PB
1
Andere Band-it Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

Swann
Swann SW-P-MC2 Bedienungsanleitung

Ecolink
Ecolink Siren+Chime Bedienungsanleitung

Digital Monitoring Products
Digital Monitoring Products XR150 Bedienungsanleitung

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung