Beckett AquaSmart Bedienungsanleitung

FrequentlyAsked Questions
1. What is theAquaSmart?
2. What is the Beckett HeatManager calculation?
3. How does this new HeatManager logic compare the HeatManager Classic we are familiar with?
4. How do you know how to set the HeatManager function for different applications?
5. How will the new HeatManager calculation interact with a system utilizing a tankless coil?
6. Does theAquaSmart have any other fuel efficiency features?
7. What other advanced features does theAquaSmart have?
8. Is theAquaSmart available in Gas applications?
9. What can cause theAquaSmart to lockout?
10. What options do I have when mounting theAquaSmart?
11. When wiring theAquaSmart does the color of the wires have any significance?
12. What are the electrical ratings of theAquaSmart?
13. Since theAquaSmart is made of plastic will the wiring knockouts hold up?
14. How difficult is theAquaSmart to program?
15. What happens if I inadvertently overlap temperature settings to be selected?
16. Generally, what is the typical operation of theAquaSmart?
17. How can I be sure that I have installed theAquaSmart correctly?
18. Does theAquaSmart provide any other benefits?
1. What is theAquaSmart?
The BeckettAquaSmart is an advanced triple acting boiler temperature control (BTC) designed for use on residential and light com-
mercial boiler systems. Atriple acting BTC incorporates a High and Low limit with differential functions.The triple acting BTC also
controls circulator functions. This employs a BTC that acts in reverse.The reverse BTC opens to turn the circulator off if boiler water
temperature drops below a set temperature, typically to maintain a minimum boiler temperature in both the High and Low limit func-
tions. The circulator circulates the heat transfer fluid to the heated zone.The BeckettAquaSmart comes equipped with the Depart-
ment of Energy (DOE) 2012 compliant HeatManager. All models include the option of enabling the Beckett HeatManager load-match-
ing energy saving calculation. When selected it provides up to 20% fuel consumption savings.
2. What is the Beckett HeatManager Calculation?
The HeatManager saves fuel by dynamically changing the temperature high operating limit to the minimum temperature necessary
to meet the heating demand. The contractor can adjust the HeatManager calculation to maximize comfort or energy savings. The
HeatManager calculation is designed to operate the boiler at its lowest possible temperature while still meeting the heating demand.
By dynamically changing the boiler temperature, it is designed to reduce the energy used by the system without sacrificing comfort.
Form No. 61772 R00, Printed in the USA 10/10
R.W. Beckett Corporation |P.O. Box 1289 |Elyria, Oh 44036 |1-800-645-2876

3. How does this new HeatManager logic compare to the HeatManager Classic we are familiar with?
As opposed to the new HeatManager calculation the Beckett HeatManager Classic works to hold off the burner from firing if
the outlet water temperature from the boiler is warm enough to still heat the home. This causes the burner to cycle less and
indirectly lowers the average boiler water temperature, which generates fuel savings.
The BeckettAquaSmart HeatManager calculation adjusts the high limit of the boiler based how long the system is on or off. If
the system is calling for heat, the adjusted high limit will increase over time but never above the high limit set point. If the sys-
tem is not calling for heat, the adjusted high limit will decrease over time. The minimum temperature theAquaSmart will allow
the adjusted high limit to drop is based on a number of factors including the high limit, low limit, differentials, and HeatManager
efficiency settings.
TheAquaSmart HeatManager never overrides the low limit, which can be beneficial in keeping hot water available in tankless
coil systems. If Domestic Hot Water Priority (DHWP) is set on one of theAquaSmart’s inputs, a priority heat call will temporarily
override the operation of the HeatManager.
4. How do you know how to set the HeatManager function for different applications?
The default HIGH efficiency setting should work best for most systems. However, there are many system factors that may have
an effect on its ability to react to changes quickly enough and supply adequate heat, such as the amount of connected radiation,
boiler size, system design temperatures, etc. The efficiency setting adjusts how aggressively the HeatManager calculation at-
tempts to reduce the boiler operating temperature. If a loss of comfort is experienced, decreasing the efficiency setting will help
regain comfort at the expense of fuel savings.
5. How will the new HeatManager calculation interact with a system utilizing a tankless coil?
The HeatManager calculation will positively affect the hot water available in a system utilizing a tankless coil.
Because the HeatManager does not change the low limit setting to accommodate the tankless coil or “hold off”
the burner when it needs to fire, you can expect more consistency in your hot water supply.
6. Does theAquaSmart have any other fuel efficiency features?
Yes, one of theAquaSmart’s advanced features is the Circulator-off delay. Once the call for heat is satisfied
the circulator-off delay holds the circulator pump on for the delay period.The Circulator-off Delay increases the efficiency of the
system by delivering more heat to the Zones instead of keeping it in the boiler or losing it up the chimney.
7. What other advanced features does theAquaSmart have?
There are several. They are as follows:
Circulator-On Delay: Once a call for heat is received the Circulator-On Delay holds the circulator pump off for the delay period.
This allows the boiler to heat up faster and spend less time in the condensing range. Consequently this reduces the amount of
condensation produced, which enhances the life of the boiler.
Domestic Hot Water Priority: The Domestic Hot Water Priority (DHWP) setting ensures that hot water will be produced when
needed by temporarily overriding the HeatManager Dynamic Temperature Reset functionality when there is a call for domestic
hot water. The Domestic Hot Water Priority has a maximum duration of twenty minutes. Circulator Seize-up Protection: There
are times when the circulator may be inactive for an extended period of time, especially during the summer months. This
feature will briefly energize the circulator periodically exercising the circulator pump, which helps to prevent seize-up during the
summer months.Automatic Freeze-up Resistance: Automatic Freeze-up Resistance is when the circulator circulates water
to all zones calling for heat during most control or system failure modes which delays or prevents pipes from freezing. This
normally happens when the burner has been in failure for one hour or theAquaSmart has been in lockout for one hour (Except
in low voltage situations).
R.W. Beckett Corporation |P.O. Box 1289 |Elyria, Oh 44036 |1-800-645-2876

Advanced 2N1 Self-checking Sensor: The 2N1AquaSmart sensor measures both “boiler water temperature” and “presence of wa-
ter” (low water cut-off) functions. TheAquaSmart’s 2N1 sensor continually performs internal self-checks to determine if the sensor is
operating properly. With theAquaSmart you can also view Boiler Cycle History
8. Is theAquaSmart available for Gas applications?
Yes, both Oil and Gas offerings are available.
9. What can cause theAquaSmart to lockout?
There are four reasons for theAquaSmart to lockout.
TheAquaSmart will lockout when the 2N1 Self-checking Sensor either detects an internal error or is not communicating prop-
erly with the control. TheAquaSmart will not reset from this condition until it can detect a properly working sensor.
When an internal safety check, such as the check on the B1 relay contacts has failed, the control will lockout. To reset from this
condition hold the “ENTER (RESET)” key for 5 seconds. If the error occurs again, replace the control.
TheAquaSmart will lockout when the “ENTER (RESET)” key is held for 5 seconds or longer. (Manual Shutdown) The control’s
operation will be temporarily suspended and will resume normal operation once the “ENTER (RESET)” button is released.
TheAquaSmart will lockout when a low water condition is detected. If the control is set to “MAN” you will need hold down the
“ENTER (RESET)” key for 5 seconds. If the control is set on “Auto” it will reset automatically.
10. What options do I have when mounting theAquaSmart?
There are two basic mounting options for theAquaSmart™ control, the immersion well method and the surface method. The surface
method is also referred to as a wall mount. Mounting theAquaSmart directly to the immersion well is the most common method. The
AquaSmart temperature sensor mounts in standard immersion wells. Surface mounting is sometimes required and is part of the
AquaSmart™ base design. It is also retrofit compatible with most standard boiler temperature controls.
11. When wiring the AquaSmart does the color of the wires have any significance?
Besides for using the white wire for neutral, black for hot and green for the ground there is no significance to the colors of the wires.
On the other hand the terminals on theAquaSmart are approved for copper wire only.
12. What are the electrical ratings for theAquaSmart?
The Burner Circuit is 120Vac for the oil control and 24Vac for gas while the Circulator Control is 120Vac. TheAquaSmart has a
120Vac Zone Control and is 24 Vac thermostats compatible.
13. Since theAquaSmart is made of plastic will the wiring knockouts hold up?
Yes, theAquaSmart control has five different knockouts. There is one on both the right and left side and three more on the bottom of
the unit. The knockouts are reinforced with a steel plate to secure conduit connectors and provide grounding.
14. How difficult is theAquaSmart to program?
TheAquaSmart control is equipped with an installer easy-to-use keypad along with a prominent
backlit LCD digital display. All of the basic functions, including High and Low Limit and High and
Low Differential are easily accessible on the face of the programming panel.
15. What happens if I inadvertently select temperature settings that overlap each other?
TheAquaSmart will not allow overlapping temperature settings to be selected. For example: If the HIGH LIMIT is set to 180°F and
both the HIGH DIFF and LOW DIFF are set to 10° F, the control will not allow a LOW LIMIT above 165° F to be entered.
•
•
•
•
R.W. Beckett Corporation |P.O. Box 1289 |Elyria, Oh 44036 |1-800-645-2876
2N1 Sensor with Low
Water Cut-off

16. Generally, what is the typical operation of theAquaSmart?
Following are typical responses to a variety of system actions.
SystemAction AquaSmart Response
Maintaining the Low Limit Burner is turned on until the water temperature reaches the low limit plus the low differential.
ZC is turned off until the water temperature reaches the low limit plus the low differential
Thermostat Call for Heat Burner is turned on as long as the water temperature is below the high limit. Circulator is
turned on after circulator-on delay if the low limit is satisfied.
Thermostat is Satisfied Burner is turned off
Circulator is turned off after circulator-off delay
ZR Call for Heat Burner is turned on as long as the water temperature is below the high limit.
ZR is Satisfied Burner is turned off.
Maintaining the High Limit Burner is turned off until the water temperature falls below the high limit minus the high
differential.
17. How can I be sure that I have installed theAquaSmart correctly?
When you have completed the installation of the unit you will go through the Control Checkout Procedure.
These procedures are typical for the default configuration of the control. Before beginning theAquaSmart checkout procedure,
make sure the control is wired and configured as is required by the application. You will find the steps for the check out procedure
in theAquaSmart Information and Operation Manual.
CAUTION! Do not leave the installation site if theAquaSmart operation did not match the descriptions in any of the steps in the
checkout procedure. Make all necessary adjustments until the correct operation is verified. The checkout procedure helps to verify
that the high and low limits are working properly and that the thermostat is wired correctly to the control.
18. Does theAquaSmart provide any other Benefits?
Yes, there are benefits provided in several different areas.
The homeowner should know that in a short period of time theAquaSmart will pay for itself when the HeatManager is enabled.
That’s right. Due to the up to 20% energy savings from our energy efficient features the homeowner will realize up to $300 sav-
ings per year in a typical home. With conserving energy and saving money theAquaSmart is precisely what consumer is looking
for.
Additionally, the homeowner benefits from increased comfort and peace of mind. TheAquaSmart will give priority to
a call for Domestic Hot Water. This helps to ensure a steady supply of hot water to the home. TheAquaSmart will also
give the homeowner added peace of mind due to its automatic freeze-up resistance feature.
Our Environment definitely Benefits with theAquaSmart. Did you know that if every Boiler in the United States used the
AquaSmart control it would reduce our nation’s fuel consumption by the equivalent of 24.6 million barrels of fuel/year?
We all can be a part of this solution.
R.W. Beckett Corporation |P.O. Box 1289 |Elyria, Oh 44036 |1-800-645-2876
Form No. 61772 R00, Printed in the USA 10/10
Andere Handbücher für AquaSmart
5
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Beckett Controller Handbücher

Beckett
Beckett HeatManager 2.5 7515 Bedienungsanleitung

Beckett
Beckett GENISYS 7565 Bedienungsanleitung

Beckett
Beckett GeniSys 7575 Bedienungsanleitung

Beckett
Beckett GeniSys Display Betriebsanleitung

Beckett
Beckett GeniSys 120V Bedienungsanleitung

Beckett
Beckett HeatManager 2.5 7516 Bedienungsanleitung

Beckett
Beckett R7184 Service-Handbuch

Beckett
Beckett Heat Manager 61572 04 Bedienungsanleitung

Beckett
Beckett AQUASMART 7600 Bedienungsanleitung

Beckett
Beckett HeatManager 2.5 7514 Bedienungsanleitung