Contents
EN ----------------------------------------- 01-17
ES ----------------------------------------- 17-34

Overview ------------------------------------
Specifications -------------------------------
Control Panel -----------------------------
Cleaning and Sterilizing Before Use --------
How to Assemble the Breast Pump ---------
How to Use the Breast Pump ---------------
Using the Expressed Milk ----------------------
Storing the Expressed Milk ---------------------
Trouble Shooting ---------------------------
Care and Maintenance ------------------------
Disposal --------------------------------------
04
04
05-07
08-10
10-12
12-13
14
14
14-16
17
17

- 01 -
WARNING
WARNING! Please read this manual carefully before using the product.
It is recommended you consult with a licensed healthcare professional before using the pump
if you have an active implanted device that would be affected by a magnetic field (e.g.
pacemaker, implantable cardioverter defibrillator)
Pumping can induce labor. Do not pump until after giving birth. If you become pregnant while
breastfeeding or breast pumping, consult with a licensed healthcare professional before
continuing.
All breast pump components that come into contact with breast milk should be disassembled,
washed, and sterilized for the first time use and before each use.
Drinking water is recommended for cleaning breast pump components that come into contact
with breast milk.
The parts that come in contact with breasts and breast milk should be disassembled and
cleaned as soon as possible after each use to prevent the growth of bacteria that may be
caused by residual milk.
All parts should NOT be exposed to ultraviolet light and should NOT be sterilized at excessively
high temperatures (<100°C/212°F) for a long time (<5 minutes).
Keep the pump dry. Clean the pump unit with a soft cloth, don't rinse/disinfect it.
Take care when cleaning thesilicone flangeand diaphragm. The breast pump will not function
properly if they get damaged.
•
•
•
•
•
•
•
•

You should avoid rubbing or inserting objects when cleaning the silicone diaphragm. Other-
wise, it may be damaged.
Do not disassemble the pump unit; pump repairs can only be performed by an authorized
service provider.
Never use the pump if it has been damaged, is not working properly, or the pump unit has
been dropped into water.
This is a single-user pump and therefore should not be used by more than one individual.
Sharing the pump among multiple users may present a health risk.
Do not use the pump while sleeping or being overly drowsy.
This product contains small parts and a cable that may present a hazard. Keep out of reach
of children.
The pump should not be used while lying down or engaging in strenuous exercise or activities
with the risk of harm.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
•
•
•
•
•
•
•
- 02 -

the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving antenna.
Increase theseparation between theequipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult thedealer or an experienced radio/TV technician for help.
—
—
—
—
- 03 -

Dust Cover x2
Flange x2
Breast Shield Body x2
Diaphragm x2
Diaphragm Cap x2
Tubing x2
USB-C Cable x1
Pump Unit x1
Duckbill Valve x2
Milk Bottle x2
Milk Bottle Lid x2
Teat x1
Teat Cap x1
Model: XN/MS-2246A
SPU: BR-HL003
Power Input: 5V 2A
Rated Power: 10W
Battery: 3.7V
Charging Port: Type C
Charging Time: 2.5 Hours
Suction Mode: 3Modes
Suction Level: 9Levels
Suction Cycle: 3Cycles (Slow/Middle/Fast)
Specifications
- 04 -
Overview

Control Panel
Left Suction Level
Press "+" or "-" to adjust
between 9 levels.
Press "+" and "-" together to
activate/deactivate the
child lock.
Side Switch Button
(Left/Dual/Right)
Power Button
Long Press:
ON/OFF
Short Press:
Pause/Resume
Timer
2-in-1 Mode
Child Lock Mute
Battery Status
- 05 -
User Mode Status
Expression Mode
Stimulation Mode
Left Side Cycle &
Cycle Button
Mode Switch Button
(Expression/Stimulation/2-in-1)
Right Suction Level
Press "+" or "-" to adjust
between 9 levels.
Press "+" and "-" together to
mute/unmute.
User Mode Button
Long Press: Start/End Recording;
Status icon blinks.
Short Press: Activate/Deactivate;
Status icon stay on or off.
Right Side Cycle & Cycle Button

Fully charge the device before first use. Long press the power button “ ” to turn on the pump
unit, and the battery status icon “ ” will stay on to show the remaining battery. Charge the
pump unit with the USB cable and power adapter (not included) when the battery is low (one
bar of power).
When the pump is turned on, press the side switch button “ ” to choose which side to pump
or to begin pumping on both sides; press the cycle button “ ” to select theoptimal suction cycle.
Press the mode switch button “ ” to select a preferred mode. The icon " " will remain visible
while in stimulation mode. After 2 minutes, the pump will automatically switch to expression
mode, and the icon " " will remain visible. The 2-in-1 mode “ ” scientifically combines the
above two modes to simultaneously stimulate and express breasts; use this mode as needed.
1.
2.
3.
- 06 -
Note: This pump is powered by a built-in li-ion battery. When the
battery status indicator shows one bar of power, it is recommended
to charge the pump as soon as possible using a certified 5V 2A
adapter (not included).
Night Light Button
Charging Port

When your nipples feel the suction power in any mode and at any suction level, press "+" or "-"
to adjust the suction to a comfortable level. There are 9 suction levels to choose from.
Press the "+" and "-" buttons on the left side together to lock the buttons and prevent acciden-
tal activation or adjustment. To mute or unmute the control panel, press "+" and "-" on the right
side simultaneously. When the child lock is enabled and the panel is muted, the status icons ""
and " " remain visible; otherwise, these icons become invisible.
While the pump unit is pumping, long press the user mode button “ " to begin recording; the
status icon “ ” will blink to show that it is recording your pumping process. When you're done
recording, long press the user mode button “ " to stop recording. You can use this function to
personalize and save your own pumping process. To repeat the saved pumping process,
activate user mode by short pressing the user mode button “ " and the pump will detect and
run the saved pumping process automatically. If no saved pumping process can be detected,
it will beep and exit user mode after short pressing the user mode button “ ".
When finished pumping, long press the power button “ ” to turn off the pump. Alternatively,
the pump will shut off automatically after 30 minutes of pumping if no further operation.
4.
5.
6.
7.
- 07 -
Inhaltsverzeichnis
Sprachen: