2|G7 EXO TECHNICAL USER MANUAL

G7 EXO TECHNICAL USER MANUAL |3
Contents
1 Overview.................................................................................................5
1.1 G7 EXO....................................................................................................5
1.2 Blackline Safety Cloud..................................................................5
1.3 Blackline Live web portal...........................................................5
1.4 G7 EXO Pump....................................................................................6
1.5 G7 EXO Diusion.............................................................................9
1.6 Connection modules ................................................................13
2 Setup.......................................................................................................14
2.1 Location..............................................................................................14
2.2 Mounting...........................................................................................14
2.3 Setup wizard....................................................................................16
2.4 Connectivity light.........................................................................16
3 User interface....................................................................................17
3.1 Buttons................................................................................................17
3.2 Screen overview ...........................................................................17
3.3 Battery..................................................................................................19
3.4 Power on/o....................................................................................20
3.5 USING EXO'S convenience features ................................21
3.6 Maintenance code......................................................................25
3.7 Alarm test ..........................................................................................25
3.8 Siren.......................................................................................................26
3.9 Speaker................................................................................................26
4 Safety alerts and alarms............................................................. 27
4.1 Lower urgency alarm................................................................27
4.2 Yellow warning alarm................................................................27
4.3 Red alert..............................................................................................28
4.4 LiveResponse..................................................................................28
5 Safety features ..................................................................................29
5.1 Functional settings......................................................................29
5.2 Gas sensor settings.....................................................................30
6 Communication.............................................................................. 31
6.1 Text messages.................................................................................31
6.2 Two-way voice calls....................................................................31
6.3 Push-to-talk (PTT).........................................................................32
6.4 Available channels.......................................................................32
6.5 Changing channels.....................................................................32
7 Gas detection.................................................................................... 33
7.1 Bump test..........................................................................................33
7.2 Calibration.........................................................................................34
7.3 Zero sensors.....................................................................................35
7.4 LEL sensor precautions ............................................................36
7.5 PID target gases ............................................................................36
7.6 Gas alert countdown.................................................................37
8 Cartridges ............................................................................................38
8.1 Cartridge options.........................................................................38
8.2 Changing cartridges..................................................................38
8.3 Sensor contaminants ................................................................38
8.4 Sensors in cold weather..........................................................38
9 Gas inlets .............................................................................................. 39
9.1 Manual calibration inlet...........................................................39
9.2 Pump inlets ......................................................................................40
9.3 Gas sampling...................................................................................40
9.4 Pump blocked alarm.................................................................40
10 Electrical ports............................................................................... 41
10.1 Cautions.........................................................................................41
10.2 Denitions....................................................................................41
10.3 Power port...................................................................................42
10.4 A/B interface ports.................................................................43
11 Over-the-air (OTA)
rmware updates.........................................................................47
12 Support...............................................................................................47
12.1 Learn more ..................................................................................47
12.2 Customer care...........................................................................47
13 Specications................................................................................. 48
13.1 Detailed specications........................................................48
13.2 Gas sensor specications...................................................49
14 Legal notices and certications.........................................50
14.1 Legal notices ..............................................................................50
14.2 INMETRO certication..........................................................50
14.3 Intrinsically safe certication...........................................51
CONTENTS

4|G7 EXO TECHNICAL USER MANUAL
WARNINGS
The Warnings listed in this section are intended to alert you to possible
hazards to people and/or equipment. The hazards may be intermittent
or permanent.
WARNING: Only remove EXO's battery in a safe environment with a
clean atmosphere. Specically, the atmosphere free of explosive gas.
See page 19.
WARNING: The EXO quick charger is NOT intrinsically safe. It should
only be used in a safe environment with a clean atmosphere.
Seepage19.
WARNING: DO NOT allow metal tools or personal items to touch the
battery terminals. Touching metal or any conductive material to the
battery terminals is extremely dangerous and will damage the battery.
Seepage 19.
WARNING: An attached trickle charger is ONLY intrinsically safe when
connected as described in the electrical diagrams in section 10.
Seepage 20.
WARNING: Listening to EXO’s siren at high volume for extended
periods of time can cause permanent hearing loss. EXO’s siren volume
should be adjusted for use indoors and in smaller spaces. Wear
appropriate ear protection during testing. Seepage 26
WARNING: EXO’s sensors must only be zeroed with clean air. If a sensor
is zeroed where its targeted gas levels are abnormal, the gas levels EXO
displays will not be accurate. Inaccurate readings are a safety hazard.
Seepage 35.
WARNING: Calibrations must only be performed in areas free of
ammable gases. Seepage36.
WARNING: O-scale (overlimit) readings may indicate an explosive
concentration. Seepage36.
WARNING: If you start the pump while operating at temperatures
of -20C or lower, EXO will generate a pump blocked alarm
(seesection9.4) that persists until the inlet warms up and begins
operating normally. In a multiple inlet sampling cycle, the inlets do not
have time to warm up. For temperatures below -20 C, use only single
gas sampling. Seepage40.
WARNING: G7 EXO Pump cannot detect the following gases: Chlorine
(Cl) and Chlorine Dioxide (ClO). Seepage40.
WARNING: Cables attached to the power port are only intrinsically safe
when properly set up with an electrical barrier. Seepage 42.
WARNING: EXO will NOT monitor during the installation process.
Seepage 47.

G7 EXO TECHNICAL USER MANUAL |5
1.1 G7 EXO
Cloud-Connected Area Monitor
G7 EXO is a cloud-connected area monitor that bundles industry-
leading gas detection with automated compliance and business
analytics tools. For the rst time ever, the days of manually collecting
data from the eld, reviewing spreadsheets and compiling reports are
behind you.
G7 EXO solves the challenges of continuous toxic and combustible gas
monitoring for sites, facilities and fence lines. Automating long-term
area monitoring and connected safety for streamlined eciency, G7
EXO allows teams to focus on their work at hand.
In the event of a safety incident or gas exposure, monitoring personnel
can see what has happened and communicate with workers directly via
text messaging or an optional two-way voice calling feature through
EXO.
1.2 BLACKLINE SAFETY CLOUD
1.3 BLACKLINE LIVE WEB PORTAL
The cloud-hosted Blackline Live web portal monitors and manages
all of your workers and G7 devices, and delivers reports and business
analytics insights.
Blackline Live
Blackline Live’s real-time alerting and live map allows you to quickly
locate and respond to gas events and other incidents in the eld.
You can use Blackline Live to create and customize conguration
proles that determine how a device or a group of devices operates in
the eld. Similarly, alert proles are set up to determine what contacts
should be notied in the event of an incident and what response
protocol monitoring personnel will follow to ensure your team gets the
help it needs.
Blackline Live keeps track of alert history and gas sensor calibrations
and bump tests, eliminating the need to manually retrieve data logs
from the eld.
Lastly, Blackline Live allows you to tailor user access depending on
employee roles: employee, supervisor, administrator and monitoring
team. This ensures that everyone has access to the right tools to
accommodate their role in a comprehensive monitoring program.
For more information about Blackline Live, visit:
support.blacklinesafety.com/products/blackline-live.
Blackline Analytics
With Blackline Analytics, you can review data collected from your
EXO eet to make decisions, follow up with your team and ensure
everything is running smoothly. Choose from a number of dierent
reports and lters to explore your data.
Blackline Analytics is built directly into the Blackline Live portal,
allowing employees with the appropriate user access controls to
see your organization’s data. If users have only been given access to
specific groups of devices, they will only see data attached to those
particular devices.
For more information about Blackline Analytics, visit
support.blacklinesafety.com/products/blackline-analytics.
1 OVERVIEW
The Blackline Safety Cloud is a cloud-hosted system consisting of
cellular networks, satellite networks, the Blackline Live™ web portal
application, your monitoring account and G7 EXO.
EXO comes with basic system access, which allows EXO to connect to
the Blackline Safety Cloud. Depending on your needs and requirements,
additional service plan options are available, including 24/7 safety
monitoring by Blackline’s Safety Operations Center and two-way voice
communication.

6|G7 EXO TECHNICAL USER MANUAL
1.4 G7 EXO PUMP
1.4.1 IN THE BOX
1.4.2 FRONT
G7 EXO Pump has a manual calibration inlet that requires a xed ow regulator to function correctly. It also has four pump inlets that can sample
air from remote areas using internal pumps and external hoses.
Pump cartridge cover
360° Air diusion vents
Connectivity light
Warning alarms
Alerts
Top light
LiveResponse light
Power button
Microphone
OK button
OK
LCD screen
Speaker
SOS latch pull
PTT latch push
Down buttonUp button
Siren
Shoulder Bumper
G7 EXO Pump safety and area gas monitor
This Technical User Manual
1m (3 ft) of hose tted with a quick connect coupling insert
Quick charger with battery pack hex key
Pre-installed multi-gas cartridge
Pre-installed cellular connection module
Pre-installed gas inlet module (one of two)
Optional pre-installed satellite connection module
Certication and support card
G7 EXO Pump comes with the following components:

G7 EXO TECHNICAL USER MANUAL |7
Mounting plate
Top light
Battery retention screws
360° Air diusion vent
Battery power gauge
Battery pack
Siren
1.4.3 BACK
1.4.4 BOTTOM

8|G7 EXO TECHNICAL USER MANUAL
Interface port B
Interface port A
Manual calibration inlet
Pump inlets
Power port
360° Air diusion vent
360° Air diusion vent
Top light
Siren
Top light
Siren
1.4.5 RIGHT SIDE
1.4.6 LEFT SIDE

G7 EXO TECHNICAL USER MANUAL |9
G7 EXO Diusion has a manual calibration inlet that requires a xed ow regulator to function correctly.
1.5 G7 EXO DIFFUSION
1.5.1 IN THE BOX
Diusion cartridge cover
360° Air diusion vents
Connectivity light
Warning alarms
Alerts
Top light
LiveResponse light
Power button
Microphone
OK button
OK
LCD screen
Speaker
SOS latch pull
PTT latch push
Down buttonUp button
Siren
Shoulder Bumper
G7 EXO Diusion safety and area gas monitor
Wind guard
This Technical User Manual
1m (3 ft) of hose tted with a quick connect coupling insert
Quick charger with battery pack hex key
Pre-installed multi-gas cartridge
Pre-installed cellular connection module
Pre-installed gas inlet module (one of two)
Optional pre-installed satellite connection module
Certication and support card
G7 EXO Diusion comes with the following components:
1.5.2 FRONT

10 |G7 EXO TECHNICAL USER MANUAL
Top light
Battery retention screws
360° Air diusion vent
Battery power gauge
Battery pack
Siren
Mounting plate
1.5.4 BOTTOM
1.5.3 BACK
Andere Handbücher für G7 EXO
4
Inhaltsverzeichnis
Andere Blackline Safety Monitor Handbücher