RIMS Rocket™ Owner’s Manual – V1
©Blichmann Engineering, LLC 2014
Operation:
Warning
: The RIMS Rocket™ electric recirculation heater is only to be used in conjunction with a
Ground Fault Circuit Interrupter (GFCI) protected power source. If you are uncertain about the status
of your power source contact a licensed and qualified electrician familiar with National Electric Code
standards before proceeding. Operating the RIMS Rocket™ electric recirculation heater in any fashion
other than described in this manual can result in personal property damage, injury, electrocution or
death.
Getting Started
The RIMS Rocket™ electric recirculation heater requires the use of a temperature control device
capable of regulating power and de-energizing the heater coil to safely operate. The RIMS Rocket™
electric recirculation heater was designed specifically for use with the Blichmann Engineering™ Tower
of Power electric temperature control module. Although the RIMS Rocket™ may be compatible with
other commercially available brewing controllers, the Tower of Power™ electric temperature control
module provides the ultimate in safety, convenience, accuracy, and precision.
To operate the RIMS Rocket™ electric recirculation heater, you must verify your system can maintain a
minimum flow rate of ¾ of a gallon per minute. If you are unable to achieve the minimum flow rate,
the power of the heater coil must be reduced. The RIMS Rocket™ electric recirculation heater is
specifically designed for use with the Tower of Power™ electric temperature control module which
provides the perfect means of controlling temperature and power.
Installation
The RIMS Rocket™ electric recirculation heater
requires a constant flow of wort, provided by a
pump, to increase and maintain the
temperature of your mash. To function properly,
it is critical that the RIMS Rocket™ is located
after the outlet of the pump and no higher
than the bottom of the mash tun. A pictorial
diagram with bold arrows indicating the
direction of flow is shown in Figure Op-1.
Figure Op-1
Pump Inlet
Pump Outlet
Temp
Sensor
Mash Tun
Temp.
Control
Module
Heater
Cable