bloom 25 GPM Installationshandbuch

BLOOM 1.5 INSTALLATION AND STARTUP
GUIDE
REFER TO OPERATING MANUAL FOR IMPORTANT SAFETY
INFORMATION

- 2 -
PAGE INTENTIONALLY LEFT BLANK

- 3 -
CONTENTS
GENERAL INFORMATION .........................................................................................................4
LOCATION REQUIREMENTS.....................................................................................................4
PARTS AND ACCESSORIES......................................................................................................5
INSTALLATION GUIDELINES.....................................................................................................6
Installation Parts and Materials..................................................................................................6
Pipe Assembly..............................................................................................................................6
Gas Connection ..........................................................................................................................7
Flooded Suction Installation ......................................................................................................7
Suction Lift Installation.................................................................................................................8
Table 4. Recommended Suction and Discharge Pipe. .................................................................9
Frame Dimensions and Components Descriptions.......................................................................9
Suction Piping Installation..........................................................................................................10
Discharge Piping Installation......................................................................................................11
CIP Valve Installation (Optional) ................................................................................................12
Connect Power to Control Box. ..............................................................................................12
QUICK STARTUP GUIDELINES................................................................................................13
Flooded Suction Applications: Pump Priming Instruction............................................................13
Suction Lift Applications: Pump Priming Instructions...........................................................15
Suction and Discharge Operation............................................................................................17
Operating Parameter Ranges...................................................................................................17

- 4 -
PAGE INTENTIONALLY LEFT BLANK

- 4 -
GENERAL INFORMATION
Read instructions thoroughly prior to assembly and installation.
All Bloom products are factory adjusted for optimal nanobubble production. Do not
adjust factory setpoints.
LOCATION REQUIREMENTS
Carefully select the BLOOM installation location based on the requirements specified in this
section. Locate and secure the BLOOM on a concrete pad or other firm, level surface that is
at least 44 in long x 23 inches wide. Maintain a clearance of at least 30 inches on all sides to
allow access for servicing and maintenance to the front and back of the BLOOM. Select a
sheltered, (weatherproof), well-ventilated area that is protected from excess moisture (i.e.,
rain, splashing, washdown water, etc.), dust and flooding. Use the schematic shown in
Figure 1 for mounting hole placement.
Figure 1. Plan view of BLOOM frame showing mounting hole placement.
The BLOOM power, suction and discharge pipe requirements are summarized in Table 1 and
Table 4 respectively.
Failure to install BLOOM within the limits specified in Tables 1 and 4 may void the
system warranty and result in poor nanobubbles production and pump cavitation.

- 5 -
Table 1. Power Requirements
PARTS AND ACCESSORIES
The parts shown in Table 2 are offered as accessories available for purchase with all BLOOM
models.
Table 2. High Pressure Oxygen Regulator Kit Parts List (P/N:99K0-001)
Image
QTY
Part Description
P/N
1
Regulator Oxygen
99J0-050
1
Hose, Welding Gas, Grade R, Green.
99C0-084
Unit
Version
Voltage
Phase
Hz
Amps
Pump Manufacturer
BLOOM 25 GPM
US
115
1
60
10.2
Pentair
US
230
1
60
6.0
Pentair
EU
230
1
50
6.9
Pentair
BLOOM 50 GPM
US
115
1
60
12.7
Pentair
US
230
1
60
6.8
Pentair
EU
230
1
50
16.9
Pentair
US
115
1
60
12.7
DAB
BLOOM 150 GPM
US
230
1
60
15.8
Pentair
EU
230
1
50
16.9
Pentair

- 6 -
NOTE: The parts shown in Table 3 are offered as accessories to the DAB pump and are only
available for purchase with the US BLOOM 50.
Table 3. Power Converter
Image
QTY
Part Description
P/N
1
Step Up- Down Transformer
99E0-235
1
Adapter
99E0-234
INSTALLATION GUIDELINES
The site conditions unique to each irrigation reservoir, irrigation room, or commercial
greenhouse project, etc., should be carefully considered when identifying the BLOOM
installation location. Refer to the Location Requirements section for addition details.
The following guidelines are recommendations for tanks with intake structure submergence.
depths less than15 ft (4.5m).
Upon delivery, unscrew the shipping screws to remove the BLOOM unit from the shipping crate.
Inspect the BLOOM for any damage or loose parts that may have occurred during transport.
Hand tightens any loose parts, make sure don’t over tight.
Installation Parts and Materials
The parts and materials required to install the BLOOM include:
•3/8 in wrench (US models) or 14mm wrench (EU models).
•7/8 in wrench (US models) or 34mm wrench (EU models). Wrench required to install the
regulator kit.
Follow
Pipe Assembly

- 7 -
Use only Schedule 40 or Schedule 80 polyvinyl chloride (PVC) pipe and fittings. Use only PVC
cement formulated for wet condition and fast installation to ensure connection between PVC
pipe to PVC fittings. Follow PVC cement manufacturer’s recommendations on cure time before
wet testing the system. Do not use black, ABS piping or mix ABS pipe with PVC pipe or fittings.
All PVC pipe connections must be airtight and leakproof. Failure to provide airtight suction
pipe connections may negatively impact nanobubble generator performance. Large
bubbles visible at the pump strainer basket are an indication of suction pipe leaks. Difficulty with
pump priming may also be the result of suction pipe leaks.
Gas Connection
For BLOOM models without onboard gas generation, connect a high pressure rated oxygen gas
line to the standard CGA-022 fitting connection. Adjust the oxygen gas regulator on the gas
supply to 100 –120 PSIG.
DO NOT EXCEED 140 PSIG SUPPLY GAS PRESSURE. Excessive pressure may
void warranty and compromise gas seals resulting in a sudden drop in backpressure.
Flooded Suction Installation
Refer to Figures 2 and 3 to determine whether the installation has a flooded suction pipe. A
flooded suction exists when the pipe between the tank and the BLOOM pump completely fills
with water when the pump is off and isolation valves are open (i.e., when the tank water
surface level is above the suction intake and the BLOOM pump). Refer to Figure 7 for BLOOM
enclosure dimensions and suction and discharge fitting locations.
Figure 2. Isometric View a Flooded Suction BLOOM installation.

- 8 -
Figure 3. Plan View of BLOOM Discharge Pipe Orientation in a Tank.
Suction Lift Installation.
Refer to Figures 5 to determine whether the installation has a suction lift pipe. A
suction lift exists when the source of liquid is located below the BLOOM centerline. The suction
pipe leading to the pump and the pump must primed to lift liquid from the tank to the BLOOM.
Figure 4. Isometric View Suction Lift Installation
Do not run the pump dry. Impeller may melt and seize, and the pump will stop running.
See Figure 3 for plan view of BLOOM suction lift pipe orientation in a Tank.

- 9 -
Table 4. Recommended Suction and Discharge Pipe.
UNIT
MAIN PIPE
TANK FITTING
ISO VALVE
CIP VALVE
UNIT INLET
BALL CHECK VALVE
25 BLOOM
2"
2"
2"
1"
2"
2"
50 BLOOM
2"
2"
2"
1"
2"
2"
150 BLOOM
3"
3"
3"
1 - 1/2"
2"
3"
Piping connections for all sizes of BLOOM are provided below. Verify the type of pump provided
with your BLOOM before beginning installation. These materials are not included with a
purchase of a BLOOM, but can be found at most hardware stores.
Frame Dimensions and Components Descriptions.
Figure 5 shows the overall BLOOM frame dimensions and the location of the suction and
discharge ports of the pump in metric and imperial units.
Figure 8 shows the major components of the BLOOM.
Figure 7. BLOOM with suction and discharge connection locations
Figure 5. BLOOM with suction and discharge connection locations
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere bloom Prüfgeräte Handbücher
Beliebte Prüfgeräte Handbücher anderer Marken

SMART
SMART KANAAD SBT XTREME 3G Series Bedienungsanleitung

Agilent Technologies
Agilent Technologies BERT Serial Bedienungsanleitung

Agilent Technologies
Agilent Technologies N3280A Bedienungsanleitung

Vernier
Vernier Go Direct Voltage Bedienungsanleitung

Lifeloc
Lifeloc R.A.D.A.R. Bedienungsanleitung

Fluke
Fluke T5-600 Bedienungs- und Montageanleitung

PCB Piezotronics
PCB Piezotronics 8159-0112A Bedienungsanleitung

BW Technologies
BW Technologies MicroDock II Bedienungsanleitung

Sun Nuclear
Sun Nuclear 1027 Bedienungsanleitung

Biomark
Biomark HPR LITE READER Bedienungsanleitung

Hioki
Hioki 3169-20 Bedienungsanleitung

Ashcroft
Ashcroft ATE-100 Bedienungsanleitung