bolid S2000-APA Bedienungsanleitung

ISO 9001
Standalone Addressable Device Programmer
S2000-APA
User’s Manual

This User’s Manual is intended to help for studying operability principles and maintenance
of S2000-APA Standalone Addressable Device Programmer.
Please read the instructions completely before connecting, operating, adjusting, or
maintaining this programmer.

S2000-APA
http://bolid.ru 3
CONTENTS
1
General........................................................................................................................................4
1.1
Specifications.........................................................................................................................4
1.2
Standard Delivery ..................................................................................................................4
1.3
Safety Precautions..................................................................................................................4
2
Description..................................................................................................................................5
2.1
Main Menu.............................................................................................................................6
2.2
Adjusting the Programmer.....................................................................................................7
2.2.1
Adjusting the Data Communication Protocol................................................................7
2.2.2
Adjusting the Backlight Brightness ...............................................................................8
2.2.3
Adjusting LCD Contrast ................................................................................................9
2.2.4
Adjusting the Time Before the Backlight Turns Off....................................................10
2.2.5
Adjusting Auto-shutdown Settings ..............................................................................11
2.2.6
Adjusting Sound Settings.............................................................................................12
2.2.7
Battery Voltage.............................................................................................................13
2.3
Changing Address................................................................................................................14
2.3.1
Changing Address of an Addressable Device Using the DPLS Protocol ....................14
2.3.2
Changing Address of an Addressable Device Using the PA Protocol..........................17
2.4
Setting Addresses.................................................................................................................20
2.5
Reading Data........................................................................................................................22
2.5.1
Reading Parameters of an Addressable Device Using the DPLS Protocol..................22
2.5.2
Reading the Status of an Addresable Device Using the PA Protocol...........................24
2.6
Information ..........................................................................................................................26
2.6.1
Programmer Data.........................................................................................................26
2.6.2
Manufacturer Data .......................................................................................................26
2.6.3
Manufacturer Address..................................................................................................26
2.6.4
Company Phone/Fax....................................................................................................27
2.6.5
Manufacturer Site and E-Mail......................................................................................27
3
Connecting to the Charger........................................................................................................28
4
Updating Programmer Firmware..............................................................................................29
5
Troubleshooting........................................................................................................................31
6
Maintenance..............................................................................................................................32
7
Storage......................................................................................................................................32
8
Transporting..............................................................................................................................32
9
Manufacturer Data....................................................................................................................32
10
Certificates................................................................................................................................32
11
Product Acceptance Certificate ................................................................................................32

ISO 9001
4
http://bolid.ru
1General
S2000-APA Standalone Addressable Device Programmer (hereinafter referred to as the APA) is
designed to assign addresses to addressable devices connected into the polling loops of S2000-KDL
controllers and addressable devices connected into the Fire Threshold Addressable alarm loops of
Signal-10 control units with PA data communication protocol. Also APA provides reading
parameters and states of the addressable devices.
1.1 Specifications
1.2 Standard Delivery
1.3 Safety Precautions
WARNING: The programmer is intended to operate at ambient temperatures 0 to 50ºC.
The programmer is powered by lithium-ion batteries, so do not expose the programmer to high and
low ambient temperatures in order to avoid battery failures.
The programmer is designed for operation in premises with regulated and unregulated climatic
conditions. The design of the programmer does not provide operating under the influence of
aggressive environment.
Parameter Value
Power Voltage
3.6 V (from built-in batteries)
Battery Capacity
800 mAh
×
2 pcs
Max Consumed Current
70 mA
Current Consumption in Quiescent Mode
10 mA
Current Consumption in Turned Off Mode
100
µ
A
Dimensions
105 mm
×
279 mm
×
58 mm
Weight
500 gram
Operating Temperatures
0 to +50°С
Ingress Protection Rating IP30
Item Q-ty
Standalone Addressable Device Programmer
1pcs.
S2000-APA Datasheet 1 pcs.
Base Adapter (to accommodate various detector types)
1 pcs.
220VAC to 5V DC PowerAdapter (1A) 1 pcs.
USB Type-A to USB Type-B Connection Cable
1 pcs.
Coffer with Belts
1 set
Packing
1 pcs.

S2000-APA
http://bolid.ru 5
2Description
To program smoke, heat, and gas detectors with addresses, APA is equipped with a DIP-34A-03
base . To program other addressable devices, install the base adapter provided into the
base. Figure 1 shows the view and the control buttons of the APA.
Figure 1. Appearance and Controls of the Programmer
1 – Base for inserting an analog addressable detector
2 – Display
3 – Keypad
4 – Base adapter (with red wire for “+PL”and blue wire for “
−
PL”)
5 – Base adapter cover
6 – USB port
1
4
1
2
3
4
5
6

ISO 9001
6
http://bolid.ru
2.1 Main Menu
1 – Name of the selected menu option
2 – Icon of the current menu option
3 – Battery indicator
4 – Indicator of the selected data communication protocol (DPLS/PA)
Switch the programmer on/off (hold the button pushed for 3 seconds).
Move between menu options.
Enter the selected menu option.
Cancel/Quit to the main menu.
The options of the main menu are as follows.
Change Address
Set Addresses
Read Parameters
Settings
Info
1
2
3
4

S2000-APA
http://bolid.ru 7
2.2 Adjusting the Programmer
2.2.1 Adjusting the Data Communication Protocol
Select Settings in the main menu by means of the buttons:
Then press :
The first menu option provides selecting the data communication protocol for the programmer to
operate with an addressable device:
The DPLS protocol (S2000-KDL)
The PA protocol (Signal-10)
By means of the buttons select the required protocol. The selected protocol will be
indicated by the icon at the upper right corner of the display:
For the DPLS protocol, and
For the PA protocol
To save changes and to return to the main menu, press .
To return to the main menu without saving changes, press .

ISO 9001
8
http://bolid.ru
2.2.2 Adjusting the Backlight Brightness
Select Settings in the main menu with the help of the buttons:
Then press .
Use the buttons in the Settings menu to select the option BL Brightness:
By the buttons adjust brightness level of the backlight.
To save changes and to return to the main menu, press .
To return to the main menu without saving changes, press .

S2000-APA
http://bolid.ru 9
2.2.3 Adjusting LCD Contrast
Select Settings in the main menu by means of the buttons:
Then press .
Select the LCD Contrast option ( ) of the Settings menu by the buttons.
Adjust the contrast level of the display by means of the buttons.
To save settings and return to the main menu, press .
To return to the main menu without saving changes, press .

ISO 9001
10
http://bolid.ru
2.2.4 Adjusting the Time Before the Backlight Turns Off
Select Settings in the main menu by means of the buttons:
Then press .
Use the buttons in the Settings menu to select the option Backlight Off:
Select the timeout value using the buttons .
To save changes and to return to the main menu, press .
To return to the main menu without saving changes, press .
Inhaltsverzeichnis
Beliebte Hauptplatine Handbücher anderer Marken

Telit Wireless Solutions
Telit Wireless Solutions SL869-3DR Bedienungsanleitung

Gigabyte
Gigabyte GA-9IVDT Bedienungsanleitung

Texas Instruments
Texas Instruments ADS8372EVM Bedienungsanleitung

Commell
Commell MS-C73 Bedienungsanleitung

IBT Technologies
IBT Technologies MB860 Bedienungsanleitung

Nvidia
Nvidia TEGRA DG-04927-001_V01 Bedienungsanleitung