BridgIoT Geasy MK6 Bedienungsanleitung

GEASY
INSTRUCTION MANUAL
Models: Mk6
Date: January 21,2020
Email: support bridgiot.co.za

Contents
Contents 1
Warranty 2
About Geasy 3
ImproperUsage ..................................... 3
Safety During Installation & Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Exclusion of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Physical Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical Specifications................................. 4
Installation procedure steps 5
Apply All Safety Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Electrical Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation 9
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety........................................... 9
User Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DeviceStatus....................................... 10
Temperature Control & Scheduling . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Burst/leak Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
User Interface ...................................... 11
Company Contact Details 17
Page 1of 17

Warranty
1. We, BridgIoT (RF) (Pty) Ltd, warrant to you that, for a 6-month period from the date
of purchase, the Geasy (from here on referred to as the “good”) will be free of any
defect.
2.If any defect in the good is discovered by you within a 6-month period from the
date of purchase, you can return the good to us or to one of our duly authorised
service agents. A good returned under this warranty must be presented to us in
its original packaging together with all accessories. We will then, at your option:
a) repair or replace the good; or
b) refund to you the price paid by you for the good.
3.If within three months after repair, the failure, defect or unsafe feature has not
been remedied, or a further failure, defect or unsafe feature is discovered, the
supplier must:
a) replace the good; or
b) refund to the consumer the price paid by the consumer for the goods.
4. We will refuse the return of any good which has been:
a) partially or wholly disassembled;
b) physically altered;
c) damaged;
d) used in a manner contrary to any instructions provided by us; or
e) permanently installed or attached and/or combined with other goods or
property in any way.
5. We will not:
a) repair the good where the defect or damage to the good is found to be a
direct result of your negligence, recklessness or malicious behaviour; and/or
b) be liable for damage caused to the good as a result of wear and tear unless
such damage manifests itself:
i. within 6months from the date of purchase (where the good has been
used for normal family, personal or household purposes); or
ii. 6months from the date of purchase (where the good has been used for
commercial or professional purposes).
6. Where we issue a refund under this warranty, we will deduct the charges we are
allowed to deduct under the Consumer Protection Act, No 68 of 2008.
7. Please note that our normal warranty does not cover any natural disasters, for
example; flooding, lightning, earthquakes, etc.
Page 2of 17

About Geasy
Geasy is suitable for installation on electric water heaters (geysers). When installing the
Geasy be sure to follow the appropriate instructions of each particular manufacturer for
all other components as well.
Installation, maintenance and dismantling may only be performed by trained personnel
in accordance with this instruction manual and safety instructions.
Use the Geasy only after first thoroughly reading and understanding this instruction
manual and the safety instructions. In the event of any ambiguities regarding the
installation and operation, consult trained personnel or contact our offices.
Improper Usage
The Geasy must not be operated in the following environments:
1. Outdoors.
2.In damp conditions.
3.In rooms in which the operation of electrical and electronic components may be
dangerous.
Safety During Installation & Use
Please take note of the following when installing, conducting maintenance or using your
Geasy:
1. Risk of death by electrocution.
2. Risk of fire due to short circuit.
3. All work on an open Geasy must be performed with the mains supply
disconnected.
4. All safety regulations apply when working on the mains supply.
5. Before connecting the Geasy, make sure that the power supply matches the
specifications on the type plate.
6. Factory labels and markings may not be altered, removed or rendered unreadable.
7. Make sure that all devices which are connected to the Geasy conform to the
technical specifications of the Geasy.
Page 3of 17

Exclusion of Liability
The manufacturer cannot monitor, or be held responsible, for compliance to this manual
or the conditions and methods during installation and operation. Improper installation
of the system may result in damage to the property and/or in bodily injury.
Therefore, we assume no responsibility for loss, damage or costs which result from or
are in any way related to incorrect installation, improper operation, incorrect execution
of installation work and incorrect usage and maintenance.
The manufacturer reserves the right to make changes to the product, technical data or
assembly and operating instructions without prior notice.
Physical Properties
Mass ~1kg
Enclosure Allbro IP66 Enlec (ENL2021509C)
Dimensions: 200 x150 x90 mm
Technical Specifications
Make BridgIoT (RF) (Pty) Ltd
Model Geasy MK6
Power Supply DIN RAIL input:
100 -240 VAC (50-60 Hz)
25 A (25 mA + LOAD)
Battery input:
9-12 VDC
420 mA
Temperature Range 0-70 °C
Page 4of 17

Installation Procedure Steps
A summary of the installation steps are as follows:
1. Apply all safety measures.
2. Complete all electrical connections.
3. Complete all sensor connections.
4. Set up the controller and all settings via the web-app.
Apply All Safety Measures
1. Switch offcircuit breaker of geyser at the main distribution board (DB).
2. Switch offthe isolator switch in the roof. The isolator disconnects the live and
neutral so that - should someone accidentally switch on the main supply or the
circuit breaker fails - there will be no power at the geyser.
3. Test with a multimeter that there is no current on the wires.
Electrical Installation Instructions
Included below is a schematic diagram of how the different components of the system
should be installed, where after step-by-step instructions are given.
Page 5of 17

Power Installation
Step-by-step instructions are included below, followed by a photo of the Geasy PCB.
1. Remove the mains supply from the geyser's thermostat.
2.Install a new length of “twin and earth”cable between the Geasy controller and
the geysers thermostat, for the electrical supply of the geyser’s heating element.
a) Connect the earth wire to the right-hand side terminal for the geyser’s supply,
labelled ‘E’
Note: The Geyser must be earthed.
b) Connect the neutral wire to the right-hand side terminal labelled ‘N’.
c) Connect the live wire to the right-hand side terminal labelled ’L-out’.
d) Now, connect the earth, neutral and live wires to the appropriate terminals
on the geyser’s thermostat.
3. Use the electrical supply from the isolation switch to power the controller:
a) Connect the earth wire to the left most terminal, labelled ‘E’
Note: The Geyser must be earthed.
b) Connect the neutral wire to the terminal located second from left and labelled
‘N’.
c) Connect the live wire to the terminal located third from left and labelled ’L’.
Page 6of 17

Sensors Installation
1. Use self-fusing silicone tape to secure the temperature sensors' flat part onto the
piping. Ensure secure attachment.
2. Attach the “Inlet”temperature to the inlet pipe, near the water meter. Attach the
“Outlet near”onto the outlet pipe as close as possible to the geyser.
3. Allow the white flex wire to rest in the drip tray, ensuring that the flex wires do not
touch (the wire connects to the “Drip”connector on the PCB).
Page 7of 17

Inserting a Sim Card
If your Geasy was supplied with a Sim Card, we will already have inserted the Sim Card
and will keep it topped up with data. If your Geasy was not supplied with a Sim Card
please follow these instructions to install the Sim Card.
1. Switch offthe power supply to the device at the isolation switch.
2. Open the enclosure of the device. (The screws only require a quarter turn)
3. Locate the sim card holder.
4. Slide the sim tray open and lift the flap.
5. Slide the micro size sim card into the tray, with its pads facing downwards.
6. Close the flap and slide the slider back until it clicks, securing the sim card.
7. Close the enclosure, securing the screws.
8. Switch the power supply on again.
Device and User Linking
There are two ways of device linking. The first, for partner organisations, is through our
installer application which can be found here. The second method of device linking is
to contact us directly at support bridgiot.co.za, including your device ID found on the
outer surface of the device and the email address used to register your user profile.
Page 8of 17

Operation
Product Description
Geasy is a smart geyser controller that enables the management of an electric water
heater (EWH), commonly known as a geyser, through an online platform. Geasy has
internet connectivity whereby it sends information and receives instructions from the
BridgIoT (RF) (Pty) Ltd web-app. The Geasy is retrofitted to an existing EWH and offers
the following functionality:
1. Switching the EWH ON and OFF by switching the supply to the heating element.
Control through:
a) scheduling or;
b) real-time temperature control.
2. Measure power consumption.
3.Internet connectivity through a cellular connection.
4. Measuring up to 3temperatures:
a) water outlet temperature and/or;
b) water inlet temperature and/or;
c) ambient temperature.
5. Optional: Detect the presence of water in the drip tray.
Safety
Do not interfere with the device. If you have to open the enclosure of the device, for
whatever reason, only do so after switching offthe power supply at the isolation switch.
Only switch on the isolation switch after the enclosure has been closed.
User Responsibilities
The user may not use the device's sim card (if supplied by BridgIoT (RF) (Pty) Ltd) for
any other purposes if the sim card was provided with the device. The sim card must,
therefore, remain within the device. The user must immediately notify BridgIoT (RF)
(Pty) Ltd, or their service provider, if the sim card is lost/stolen.
Page 9of 17