Brigade 27" Wide Single Oven Bedienungsanleitung

Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-845-4641
or visit our web site at www.brigade.ca
F21103 EN
BRIGADE
TM
(030113)
Installation Guide
Professional Custom
Built-In Electric Single and Double Ovens

3
IMPORTANT–Please Read and Follow!
Table of Contents
Warnings & Important Safety Instructions _______________________________________________3
Dimensions-Professional Single________________________________________________________6
Specifications & Electrical Requirements-Professional Single ______________________________7
Cutout Dimensions-Professional Single Built-In __________________________________________8
Cutout Dimensions-Professional Single Undercounter ____________________________________9
Dimensions-Professional Double _____________________________________________________10
Specifications & Electrical Requirements-Professional Double ____________________________11
Cutout Dimensions-Professional Double Built-In ________________________________________12
Flush Mount Install 27”______________________________________________________________14
Flush Mount Install 30”______________________________________________________________18
General Information ________________________________________________________________22
Installation_________________________________________________________________________23
Performance Checklist ______________________________________________________________27
Final Preparation ___________________________________________________________________29
Service & Registration_______________________________________________________________29
2
• Before beginning, please read these
instructions completely and carefully.
• DO NOT remove permanently affixed
labels, warnings, or plates from product.
This may void the warranty.
• All local and national codes and ordinances
must be observed. Installation must
conform with local codes.
• The installer must leave these instructions
with the consumer who should retain for
local inspector’s use and for future reference.
In Massachusetts: This appliance must be installed
by a Massachusetts licensed plumber or electrician.
In Canada: Installation must be in accordance
with the current CSA C22.1 Canadian
Electrical Codes Part 1 and/or local codes.
Your safety and the safety of others is
very important.
We have provided many important safety
messages in this manual and on your
appliance. Always read and obey all
safety messages.
This is the safety alert symbol. This
symbol alerts you to hazards that
can kill or hurt you and others.
All safety messages will be preceded by
the safety alert symbol and the word
“DANGER,” “WARNING” or “CAUTION.”
These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death
DANGER
Hazards or unsafe practices
which COULD result in severe personal
injury or death
Hazards or unsafe practices which
COULD result in minor personal injury or
property damage.
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
CAUTION

WARNING
To prevent possible damage to cabinets
and cabinet finishes, use only materials
and finishes that will not discolor or
delaminate and will withstand temperatures
up to 194°F (90°C). Heat resistant
adhesive must be used if the product is to
be installed in laminated cabinetry. Check
with your builder or cabinet supplier to
make sure that the materials meet these
requirements.
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local
laws, or local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any significant sources of water or moisture.
• Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which
are not installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
IMPORTANT–Read and Follow!
DANGER
ELECTRICAL SHOCK
HAZARD
To avoid risk of electrical shock,
personal injury or death; verify
your appliance has been properly
grounded in accordance with local codes
or in absence of codes, with the National
Electrical Code (NEC). ANSI/NFPA 70-
latest edition.
WARNING
MOVING HAZARD
To avoid risk of severe
personal injury; this appliance
requires two or more personnel while
handling and moving. Possible use of
appliance moving devices is recommended.
WARNING
DO NOT use the handle or oven door to lift
the oven. Remove door before installation
to ensure that it is not used to lift the unit.
Make sure pins are inserted into hinges
before removing door to prevent injury to
hands and/or fingers.
WARNING
The misuse of the oven door(s) (e.g.
stepping, sitting, or leaning on them) can
result in hazards or injuries and damage to
the product.
WARNING
The use of cabinets for storage above the
oven may result in potential fire or burn
hazard.
WARNING
This appliance should not be used for
space heating. This information is based
on safety considerations.
5
4

Specifications & Electrical Requirements
Dimensions–Single Oven
(Professional Series–Mechanical and Touch Control Models)
25–3/4”
(
65.4 cm)
20
–
1/2”
(52.1 cm)
46”
(116.8 cm)
29
–
1/2”
(74.9 cm)
29-1/2”
(74.9 cm)
25–3/4”
(
65.4 cm)
20
–
1/2”
(52.1 cm)
46”
(116.8 cm)
26
–
1/2”
(67.3 cm)
29-1/2”
(64.9 cm)
8”
(
20.3 cm)
7-3/8”
(18.7 cm)
5-3/8”
(13.6 cm)
8”
(
20.3 cm)
7
–
3/8”
(18.7 cm)
5-3/8”
(13.6 cm)
30” Wide
Rating Label
Location
27” Wide
Rating Label
Location
Professional Single Oven
Description
27” Wide Models 30” Wide Models
Overall Width 26-1/2” (67.3 cm) 29-1/2” (74.9 cm)
Overall Height 29-1/2” (74.9 cm)
Overall Depth to edge of door—25-3/4” (65.4 cm)
with door open—46” (116.8 cm)
Cutout Width Standard—25-1/2” (64.8 cm)
Flush Mount—26-15/16” (68.4 cm)
Standard—28-1/2” (72.4 cm)
Flush Mount—29-15/16” (76.0 cm)
Cutout Height Standard—28-1/8” (71.4 cm)
Flush Mount—30-3/8” (77.2 cm)
Cutout Depth Standard—24” (60.9 cm)
Flush Mount—25-3/4” (65.4 cm)
Electrical Requirements 4-wire ground, 240VAC, 30 amp electrical connection
Unit equipped with No.10 ground wire in unit. Fuse separately.
Maximum Amp Usage 24.0 amps—240 VAC
20.8 amps—208 VAC
Oven Interior Width 22-5/16” (56.7 cm) 25-5/16” (64.3 cm)
Oven Interior Height 16-1/2” (41.9 cm)
Oven Interior Depth 16-13/16” (42.7 cm)
Oven Volume
(measured to AHAM standard)*
3.6 cu. ft. 4.1 cu. ft.
Oven Volume
(total oven cavity)
4.1 cu. ft. 4.7 cu. ft.
Approximate Shipping Weight 237 lbs. (108 kg) 261 lbs. (118 kg)
*The AHAM Standard for measuring oven capacity subtracts the door plug and convection baffle dimension from the total
oven volume.
7
6

Cutout Dimensions–Single Oven
(Professional Series–Mechanical and Touch Control Models)
5” Min.
(12.7 cm)
4”
(10.2 cm)
4–3/4”
(12.1 cm)
28–1/2”
(72.4 cm)
Flush Mount
29-15/16”
(76.0 cm)
24”
(61.0 cm)
Flush Mount
25-3/4”
(65.4 cm)
28–1/8”
(71.4 cm)
Flush Mount
30-3/8”
(77.2 cm)
25–1/2”
(64.8 cm)
Flush Mount
26-15/16”
(68.4 cm)
24”
(61.0 cm
)
Flush Mount
25-3/4”
(65.4 cm)
28–1/8”
(71.4 cm)
Flush Mount
30-3/8”
(77.2 cm)
5” Min.
(12.7 cm)
4”
(10.2 cm
)
Make sure
walls are
perpendicular
4–3/4”
(12.1 cm)
Make sure
walls are
perpendicular
Junction
Box
Location
Junction
Box
Location
27” Wide Undercounter
30” Wide Undercounter
Cutout Dimensions–Single Oven
(Professional Series–Mechanical and Touch Control Models)
28–1/8”
(71.4 cm)
Flush Mount
30-3/8”
(77.2 cm)
17”
(43.2 cm)
Min. to floor
25–1/2”
(64.8 cm)
Flush Mount
26-15/16”
(68.4 cm)
24”
(60.9 cm)
Flush Mount
25-3/4”
(65.4 cm)
5” Min.
(12.7 cm)
4”
(
10.2 cm)
Junction
Box
Location
Make surewalls
are perpendicular
27” Wide Built-In
Note: A minimum of 2” (5.1 cm) spacing above and below the oven to any adjacent items is
required for ventilation purposes.
28–1/8”
(71.4 cm)
Flush Mount
30-3/8”
(77.2 cm)
17”
(43.2 cm)
Min. to floor
24”
(60.9 cm)
Flush Mount
25-3/4”
(65.4 cm)
Make surewalls
are perpendicular
5” Min.
(12.7 cm)
4”
(
10.2 cm)
Junction
Box
Location
28–1/2”
(72.4 cm)
Flush Mount
29-15/16”
(76.0 cm)
30” Wide Built-In
9
8

Specifications & Electrical Requirements
Dimensions–Double Oven
(Professional Series–Mechanical and Touch Control Models)
25–3/4”
(
65.4 cm)
20
–
1/2”
(
52.1
cm)
46”
(
116.8
cm)
29–1/2”
(74.9 cm)
51
–
7/8”
(131.7 cm)
25–3/4”
(
65.4 cm)
20
–
1/2”
(52.1 cm)
46”
(116.8 cm)
26
–
1/2”
(67.3 cm)
51
–
7/8”
(131.7 cm)
27” Wide
30” Wide
Rating Label
Location
(behind door)
Professional Double Oven
Description
27” Wide Models 30” Wide Models
Overall Width 26-1/2” (67.3 cm) 29-1/2” (74.9 cm)
Overall Height 51-7/8” (131.7 cm)
Overall Depth to edge of door—25-3/4” (65.4 cm)
with door open—46” (116.8 cm)
Cutout Width Standard—25-1/2” (64.8 cm)
Flush Mount—26-15/16” (68.4 cm)
Standard—28-1/2” (72.4 cm)
Flush Mount—29-15/16” (76.0 cm)
Cutout Height Standard—50-5/8” (128.6 cm)
Flush Mount—52-7/8” (134.3 cm)
Cutout Depth Standard—24” (60.9 cm)
Flush Mount—25-3/4” (65.4 cm)
Electrical Requirements 4-wire ground, 240VAC, 50 amp electrical connection
Unit is equipped with No.10 ground wire in conduit.
Should be fused separately.
Maximum Amp Usage 40.0 amps—240 VAC
34.7 amps—208 VAC
Oven Interior Width–both ovens 22-5/16” (56.7 cm) 25-5/16” (64.3 cm)
Oven Interior Height–both ovens 16-1/2” (41.9 cm)
Oven Interior Depth Upper Oven:
16-13/16” (42.7 cm) - AHAM
19-1/2” (49.5 cm) - Overall
Lower Oven - CVEDO1272/CVEDO1302(T):
18-1/2” (46.9 cm) - AHAM
19-1/2” (49.5 cm) - Overall
Lower Oven - CVEDO5272/CVEDO5302/CVEDO5302T:
16-13/16” (42.7 cm) - AHAM
19-1/2” (49.5 cm) - Overall
Oven Volume
(measured to AHAM standard)*
Upper Oven: 3.6 cu. ft.
Lower Oven:
CVEDO1272: 4.0 cu. ft.
VEDO5272: 3.6 cu. ft.
Upper Oven: 4.1 cu. ft.
Lower Oven:
CVEDO1302(T): 4.5 cu. ft
CVEDO5302/CVEDO5302T: 4.1 cu. ft.
Oven Volume
(Overall)
Both Ovens: 4.1 cu. ft. Both Ovens: 4.7 cu. ft.
Approximate Shipping Weight 360 lbs. (163 kg) 402 lbs. (182 kg)
*The AHAM Standard for measuring oven capacity subtracts the door plug and convection baffle dimension from the total
oven volume.
11
10

Cutout Dimensions–Double Oven
(Professional Series–Mechanical and Touch Control Models)
Cutout Dimensions–Double Oven
(Professional Series–Mechanical and Touch Control Models)
50–5/8”
(128.6 cm)
Flush Mount
52-7/8”
(134.3 cm)
15–1/4”
(38.7 cm)
min. to floor
25–1/2”
(64.7 cm)
Flush Mount
26-15/16”
(68.4 cm)
24”
(60.9 cm)
Flush Mount
25-3/4”
(65.4 cm)
5” Min.
(12.7 cm
)
4”
(10.2 cm)
Junction
Box
Location
Make surewalls
are perpendicular
27” Wide Built-In
50–5/8”
(128.6 cm)
Flush Mount
52-7/8”
(134.3 cm)
28–1/2”
(72.4 cm)
Flush Mount
29-15/16”
(76.0 cm)
24”
(60.9 cm)
Flush Mount
25-3/4”
(65.4 cm)
5” Min.
(12.7 cm)
4”
(10.2 cm)
Junction
Box
Location
Make surewalls
are perpendicular
15–1/4”
(38.7 cm)
min. to floor
30” Wide Built-In
Note: A minimum of 2” (5.1 cm) spacing above and below the oven to any adjacent items is
required for ventilation purposes.
13
12

Dimensions (27” Single Oven flush mount installation)
Finished
Surfaces
Vertical
Blocking
ED
F3/4” Base
Blocking
LEGEND
Blocking
Finished
Surfaces
Note: To install the professional custom oven in a flush mount application the flush mount
accessory kit is required.
Dimensions (27” Double Oven flush mount installation)
Note: To install the professional custom oven in a flush mount application the flush mount
accessory kit is required.
SINGLE OVEN
FLUSH CUTOUT
D 26-15/16” (68.4 cm)
E 25-3/4” (65.4 cm)
F 30-3/8” (77.2 cm)
Finished
Surfaces
Vertical
Blocking
BA
C
3/4” Base
Blocking
LEGEND
Blocking
Finished
Surfaces
DOUBLE OVEN
FLUSH CUTOUT
A 26-15/16” (68.4 cm)
B 25-3/4” (65.4 cm)
C 52-7/8” (134.3 cm)
15
14

Dimensions (27” Flush mount installation)
Dimensions (27” Flush mount installation)
Screw
Vertical
Blocking
Distance will vary
depending on the
cabinet
C
Screw
B
A
Top View
CRITICAL
DIMENSIONS
A 26-15/16” (68.4 cm)
B 2-1/2” (6.4 cm)
C 1/2” (1.3 cm)
Vertical
Blocking
Base
Blocking
D
B
LEGEND
Blocking
Cabinet
Cross Section
Side View
CRITICAL
DIMENSIONS
B 2-1/2” (6.4 cm)
D 3” (7.6 cm)
17
16

Dimensions (30” Single Oven flush mount installation)
Finished
Surfaces
ED
F
Vertical
Blocking
3/4” Base
Blocking
LEGEND
Blocking
Finished
Surfaces
Note: To install the professional custom oven in a flush mount application the flush mount
accessory kit is required.
Note: To install the professional custom oven in a flush mount application the flush mount
accessory kit is required.
Finished
Surfaces
BA
C
Vertical
Blocking
3/4” Base
Blocking
LEGEND
Blocking
Finished
Surfaces
Dimensions (30” Double Oven flush mount installation)
SINGLE OVEN
FLUSH CUTOUT
D 29-15/16” (76.0 cm)
E 25-3/4” (65.4 cm)
F 30-3/8” (77.2 cm)
DOUBLE OVEN
FLUSH CUTOUT
A 29-15/16” (76.0 cm)
B 25-3/4” (65.4 cm)
C 52-7/8” (134.3 cm)
19
18
Andere Handbücher für 27" Wide Single Oven
1
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Brigade Ofen Handbücher