Brookstone Steam Bug Bedienungsanleitung

Steam Bug™

1
Table of conTenTs
Location of Parts and Accessories2
Location of Controls 3
Control Information 4-5
Operation5-8
Cleaning and Storage8-9
Specications10
Warnings and Cautions 11-14
Warranty 15-16

2
locaTion of parTs & accessories
Travel Case
Measuring Cup
Stands (2)
Hand Grip
Ironing Plate
1
2
3
4
5
Internal Water Tank
Heating Indicator Light
Power Cord Clip
Control Panel (see p 3)
Power Cord
6
7
8
9
10
1
3
4
5
7
8
10
2
9
6
MAX

3
locaTion of conTrols
Water Tank Cap
Water Tank Windows (2)
Steam Button
Temperature Dial
1
2
3
4
Settings Indicator Arrow
Voltage Selector
Voltage Selector Switch
5
6
7
1
2
3
5
2
4
6
Large view of Voltage Selector
7

4
conTrol informaTion
The IRONING PLATE is the heated, non-stick surface that is used to press
fabrics, remove wrinkles and create creases
The HEATING INDICATOR LIGHT illuminates when the Temperature Dial is set
to one of the three heat settings
The POWER CORD CLIP holds the power cord securely when wrapped around
the base of the Hand Grip for storage
The WATER TANK CAP covers the Water Tank fill hole The Water Tank Cap
is tethered to the unit, and cannot be completely removed
The WATER TANK WINDOWS let you monitor the level of water in the Water
Tank The unit must be sitting upright to correctly read the water level
The STEAM BUTTON is pressed to activate the unit's steam function
Locking the Steam Button down disables steam; pressing the Steam Button
releases it into the unlocked position, enabling steam
The TEMPERATURE DIAL is turned to select one of three heat settings,
and to turn heating off
The SETTINGS INDICATOR ARROW tells you at what temperature your
dial is set
The HAND GRIP is ergonomically designed for user comfort The Hand Grip
contains the unit's Water Tank, and the base is specially designed for the power
cord to be wrapped around for storage
The INTERNAL WATER TANK, located inside the Hand Grip, is designed
to hold a maximum of 1 oz of water
•
•
•
•
•
•
•
•
•
•

The VOLTAGE SELECTOR is the recessed switch which is used to set
the unit to either 100-127V or 220-240V electrical voltage standards
By default the Voltage Selector is set to 100-127V
The STANDS are the two supports located at the rear of the main body
The Stands are designed to support the unit in an upright position when
the Ironing Plate is hot
The MEASURING CUP is designed to help you easily and consistently
fill the Water Tank with the optimum amount of water
operaTion
Main body surface can get hot Grip the Steam Bug™ using the HAND GRIP only
Steam Bug™ is dual-voltage, which allows it to function correctly in regions with
either 100-127V or 220-240V electrical voltage standards Voltage is set using
the VOLTAGE SELECTOR
•
•
•
5

To change the voltage from 100-127V default setting:
Locate the VOLTAGE SELECTOR SWITCH, recessed inside the slot at the rear
of the Steam Bug™ (see below)
2 Slide the VOLTAGE SELECTOR SWITCH to the right, so that it is closest to
the 220-240V label (A pen tip may be used)
3 Unit is now ready for use in a 220V region
4 To use again in a 100-127V region, slide the VOLTAGE SELECTOR SWITCH
to the left, so that it is the closest to the 100-127V label
Place unit (IRONING PLATE down) on a flat, heat-resistant surface
Fill MEASURING CUP with water up to MAX mark
3 Open WATER TANK CAP
4 Pour water from MEASURING CUP into INTERNAL WATER TANK
5 Close WATER TANK CAP
1
1
2
6
Voltage Selector Switch

7
Turn TEMPERATURE DIAL clockwise as far as possible to set unit to high
temperature (MAX) HEATING INDICATOR LIGHT will illuminate
When HEATING INDICATOR LIGHT turns off, press the STEAM BUTTON
The button will lock into raised position, and unit will begin emitting steam
from steam vents on IRONING PLATE
3 To stop steam flow, press the STEAM BUTTON again to lock it into
lowered position
1 Plug in POWER CORD
2 Turn the TEMPERATURE DIAL clockwise so that the SETTINGS INDICATOR
ARROW points to one of three heat settings on the TEMPERATURE DIAL
The HEATING INDICATOR LIGHT will illuminate
3 When the HEATING INDICATOR LIGHT turns off, IRONING PLATE is heated
and ready for use
1
2

8
cleaning and sTorage
Turn the TEMPERATURE DIAL to the OFF (O) position
Unplug POWER CORD, and if iron is hot, prop it upright on STANDS to
cool for at least 30 minutes
Open WATER TANK CAP and drain any remaining water Close cap
when finished
Wipe main body of iron and IRONING PLATE with a soft cloth lightly
moistened with water
DO NOT clean IRONING PLATE with detergents or descalers.
DO NOT clean IRONING PLATE with abrasive or corrosive products.
DO NOT submerge unit or hold unit under running water.
5 Wrap POWER CORD around base of HAND GRIP and secure the end
in the POWER CORD CLIP
1
2
3
4
•
•
•

9
Follow steps 1-3 under the Cleaning And Storage section, but leave the
WATER TANK CAP open
Make a mixture of 1/2 distilled water and 1/2 vinegar using the included
MEASURING CUP
Pour water/vinegar mixture into INTERNAL WATER TANK
Close WATER TANK CAP
Follow normal steam iron procedure, and allow unit to steam out the full
contents of the water tank
When finished, lock STEAM BUTTON in lowered position and unplug unit
Allow to cool for 5 minutes, then refill INTERNAL WATER TANK with fresh
distilled water Repeat STEP 4 until vinegar odor dissipates
Allow unit to cool, then store unit as normal
1
2
3
4
5
6
7
8
Inhaltsverzeichnis
Andere Brookstone Eisen Handbücher