BrookVent aircycle 1.3 Montageanleitung

V. 1.3-24-04-19
brookvent.co.uk
VERSATILE
Heat Recovery Ventilation
Installation, maintenance & user manual
Applicable to the following aircycle 1.3 & 1.3+ models:
aircycle MVHR
Product Type
aircycle 1.3
Potentiometer Control
aircycle 1.3+
Potentiometer Control
c/w Humidistat, Bypass - Wall Mount
AS 90-0103-WINS-01
AS 90-0103P-WINS-01
c/w Humidistat, Bypass - Floor Mount
AS 90-0103-FINS-01
AS 90-0103P-FINS-01
c/w Humidistat, Bypass - Ceiling Mount
AS 90-0103-CINS-01
AS 90-0103P-CINS-01
Product codes shown refer to "Standard" duct configuration.
Add "V" to the end of each product code for an "inverted duct configuration.
AND HIGHLY
QUIET, EFFICIENT

1
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
CONTENTS
PLEASE KEEP THESE INSTRUCTIONS WITH THE PRODUCT.
Please read this manual fully prior to installing the MVHR unit.
1.0 Introduction ........................................................................................................................2
2.0 Safety ..................................................................................................................................4
3.0 Specifications/ Dimensions (mm) .......................................................................................6
4.0 Installation ........................................................................................................................11
5.0 Electrical Connections/ Wiring .........................................................................................20
6.0 Controls and Settings........................................................................................................21
7.0 Maintenance.....................................................................................................................27
8.0 User Operation..................................................................................................................35
9.0 Trouble Shooting...............................................................................................................40

2
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
IMPORTANT
This appliance is not intended for use by persons (including children) with reduced
physical sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
1.0 Introduction
The Brookvent aircycle 1.3 is a compact and highly efficient Mechanical Heat Recovery
Ventilation (HRV/MHRV) system, specifically designed for smaller dwellings and
apartments with restricted space.
The system should be run continuously 24 hours a day, and should only be disconnected
by a competent person during service or maintenance.
Heat Recovery ventilation works best in new homes, which are extremely airtight and
have high efficiency ratings. These dwellings require a high level of fresh air to ensure a
healthy living environment.
The system works by drawing stale air from ‘wet rooms’ such as Bathrooms, WC’s and
Kitchens, recovering up to 92% of the heat from this air using a highly efficient heat
exchanger, before expelling waste air from the home. Simultaneously, fresh air is drawn
into the home, filtered and warmed by the recovered heat and supplied into the
‘habitable rooms’ such as bedrooms, dining rooms and living rooms.

3
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
1.1 Model Variations
aircycle MVHR
Product Type
aircycle 1.3
Potentiometer
Control
aircycle 1.3+
Potentiometer Control
c/w Humidistat, Bypass - Wall Mount
AS 90-0103-WINS-01
AS 90-0103P-WINS-01
c/w Humidistat, Bypass - Floor Mount
AS 90-0103-FINS-01
AS 90-0103P-FINS-01
c/w Humidistat, Bypass - Ceiling Mount
AS 90-0103-CINS-01
AS 90-0103P-CINS-01
Product codes shown refer to "Standard" duct configuration.
Add "V" to the end of each product code for an "inverted duct configuration.
1.2 Product Guarantee
This product is guaranteed against defects for a period of 5 years from date of purchase
with the first year covering parts and labour and the remaining 4 years covering parts
only.
In the instance of a defect, Brookvent may repair the product, replace the product free of
charge or refund the cost of the product at Brookvent’s own discretion. In terms of
installation, operation and maintenance please follow all instructions provided. If this
product has been misused, not properly maintained or handled carelessly it may lead to
this guarantee being declared void.
Brookvent does not accept liability for damage caused by non-observance of the
installation instructions. Service activities must be carried out by Brookvent or by
competent installers using original Brookvent parts. This guarantee does not affect your
statutory right as a consumer.
Brookvent operate a policy of continuous innovation and improvement and thus
reserve the right to alter product specifications and appearances without notice.

4
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
2.0 Safety
The following information must be read carefully to ensure safe installation and
operation of the Brookvent HRV system.
2.1 General Safety
▪Do not use this appliance for functions other than those described in this booklet.
▪Never touch the appliance with wet hands.
▪The unit is only suitable for 230 VAC/50Hz electric mains.
▪Never modify the fan or electronics, all repairs must be conducted by Brookvent.
▪Never connect the power if electronics cover is not fitted.
▪Never connect the power if either of the fan covers are not fitted.
▪Do not store inflammable products in close proximity to the unit.
▪If cleaning/ dusting the external surface, do so with a dry cloth only.
2.2 Responsibility of the Installer
▪Correct Installation, balancing and commissioning of the MHRV unit.
▪Record measured air flow volumes on each of the valves at High and Low rate.
▪Compliance to requirements and local additional rules.
▪Explanation of the ventilation system to the user.
▪Warning for the user, to check or replace the air filters on time.
▪All the above, as set out in the latest edition of the Domestic Ventilation
Compliance Guide and the SAP Appendix Q –Installation Guide and Checklist
specific to the UK market.
2.3 Responsibility of the Occupant
▪Replacement of the filters as per the recommended/ required interval.
▪Cleaning the valves in the rooms regularly to prevent blockage.
▪To ensure that the system is functioning properly on a regular basis
▪To use manual boost switches (where provided) to prevent build-up of pollutants
or mould growth.

5
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
IMPORTANT
Dirty or clogged filters may cause inadequate ventilation in the home which may lead to
air quality issues. It is important that the filters are changed at least once per year or as
required.
In new build properties it may be prudent to check/ change your filters after the first 3
months of occupancy depending on the amount of residual ‘building dust’ present
within the property. Failure to do so will affect your warranty.
Filters can be purchased directly online from brookvent.co.uk

8
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
3.2 Detailed Specification
Weight: 11kg
Materials:
• Main enclosure: High density, impact resistant EPP (Expanded Polypropylene)
• PCB & control panel enclosure: ABS FR
• Filters: Polyester media (G3)
• Filter cover: Rubber
• Mounting Bracket: Zinc Plated Steel
• Fan Scrolls: ABS
Electrical & Controls:
• 230v EC Low energy, backward curved centrifugal fans
• Supplied complete with 4 core flying lead: (Live: Brown), (Neutral: Black),
(Earth: Yellow & Green), (230v Switched Live (Boost): Grey)
• Plug and play fan components for easy maintenance
Standards:
Fully complies with Building Regulations for UK & Ireland
SAP Appendix Q Listed | Energy Savings Trust Best Practice | CE

9
V. 1.3-24-04-19
brookvent.co.uk
www.brookvent.co.uk T: +44 (0) 28 9061 6505
3.3 SAP Appendix Q Results
3.4 Airflow: Pressure/ Performance Curve –aircycle 1.3
0.0
50.0
100.0
150.0
200.0
250.0
300.0
350.0
400.0
450.0
500.0
550.0
600.0
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0
Pressure (Pa)
Airflow (l/s)
Aircycle 1.3
100% 90% 70% 50% 30%
100%
90%
70%
50%
30%
Dieses Handbuch passt für folgende Modelle
7
Inhaltsverzeichnis
Andere BrookVent Heizsystem Handbücher