BW Technologies GasAlertMax XT II Gebrauchs- und Pflegehandbuch

1, 2, 3, and 4-Gas Detector
Technical Reference Guide

Table of Contents
Title Page
Contacting BW Technologies by Honeywell .................................................................................................................... 1
Introduction ......................................................................................................................................................................... 1
Gases Monitored ............................................................................................................................................................. 2
Safety Information - Read First.......................................................................................................................................... 2
Getting Started .................................................................................................................................................................... 6
Parts of the GasAlertMax XT II........................................................................................................................................... 7
Display Elements ................................................................................................................................................................ 8
Activating/Deactivating the Detector .............................................................................................................................. 10
Startup Tests ..................................................................................................................................................................... 10
Battery Test ................................................................................................................................................................... 10
Audible/Visual Test ........................................................................................................................................................ 10
Firmware Version ..................................................................................................................................................... 11
Startup Message ...................................................................................................................................................... 11
Location Logging ...................................................................................................................................................... 11
Pump Test on Startup.................................................................................................................................................... 12
Alarm Setpoints ............................................................................................................................................................. 13
Self-Test ........................................................................................................................................................................ 14
Automatic Zero for H2S, CO, O2, and LEL .................................................................................................................... 15
If Previous Calibration Failed ......................................................................................................................................... 15
Calibration Due Date (optional) ..................................................................................................................................... 16
Force Calibration Enabled (optional) ............................................................................................................................. 16
Cal IR Lock Enabled (optional) ...................................................................................................................................... 17
If Previous Bump Failed................................................................................................................................................. 17

GasAlertMax XT II
Technical Reference Guide
Title Page
Bump Test...................................................................................................................................................................... 17
Force Bump Enabled (optional) ..................................................................................................................................... 18
Startup Test Pass .......................................................................................................................................................... 18
Startup Test Fail............................................................................................................................................................. 19
Installing Fleet Manager II ................................................................................................................................................ 20
Using Fleet Manager II to Configure the Detector ......................................................................................................... 20
Device Configuration ........................................................................................................................................................ 21
Serial Number Field ....................................................................................................................................................... 22
Firmware Version........................................................................................................................................................... 22
Hardware Version .......................................................................................................................................................... 22
Startup Message Top Line ............................................................................................................................................. 22
Startup Message Bottom Line........................................................................................................................................ 22
Lockout on Self-Test Error (failed sensor lock) .............................................................................................................. 22
Safe Mode...................................................................................................................................................................... 23
Confidence Beep ........................................................................................................................................................... 23
Latching Alarms ............................................................................................................................................................. 23
Force Calibration............................................................................................................................................................ 23
Force Bump ................................................................................................................................................................... 24
Cal IR Lock .................................................................................................................................................................... 24
Location Logging............................................................................................................................................................ 25
Force Block Test ............................................................................................................................................................ 25
Datalog Interval.............................................................................................................................................................. 25
Confidence Interval ........................................................................................................................................................ 26
Language ....................................................................................................................................................................... 26
Sensor Configuration ....................................................................................................................................................... 26
Sensor Disabled............................................................................................................................................................. 27
Calibration Gas (ppm).................................................................................................................................................... 27

GasAlertMax XT II
Technical Reference Guide
Title Page
Calibration Interval ......................................................................................................................................................... 28
Bump Interval................................................................................................................................................................. 28
Low Alarm ...................................................................................................................................................................... 28
High Alarm ..................................................................................................................................................................... 28
TWA Alarm..................................................................................................................................................................... 29
STEL Alarm.................................................................................................................................................................... 29
STEL Interval ................................................................................................................................................................. 30
TWA Period (hours) ....................................................................................................................................................... 30
Correction Factor (%)..................................................................................................................................................... 30
50% LEL = (%CH4)........................................................................................................................................................ 31
Auto Zero on Startup...................................................................................................................................................... 31
LEL by Volume CH4 ...................................................................................................................................................... 31
10% (of reading) Over-span........................................................................................................................................... 31
20.8 Base Reading ........................................................................................................................................................ 31
Low Alarm Acknowledge................................................................................................................................................ 31
Alarms ................................................................................................................................................................................ 32
Computed Gas Exposures ............................................................................................................................................... 35
Viewing and Clearing Gas Exposures ........................................................................................................................... 35
Gas Alarm Setpoints ...................................................................................................................................................... 36
Resetting Gas Alarm Setpoints...................................................................................................................................... 37
Stopping a Gas Alarm .................................................................................................................................................... 37
Sensor Alarm ................................................................................................................................................................. 37
Pump Alarm ................................................................................................................................................................... 38
Low Battery Alarm.......................................................................................................................................................... 38
Automatic Deactivation Alarm ........................................................................................................................................ 38
Bump Test.......................................................................................................................................................................... 39
Bump Test Using the MicroDock II Station .................................................................................................................... 39

GasAlertMax XT II
Technical Reference Guide
Title Page
Calibration ......................................................................................................................................................................... 40
Guidelines ...................................................................................................................................................................... 40
Diagnostics Protection ................................................................................................................................................... 41
Connecting the Gas Cylinder to the Detector ................................................................................................................ 41
Calibration Procedure .................................................................................................................................................... 42
Auto Zero Sensor...................................................................................................................................................... 43
Auto Span ................................................................................................................................................................. 44
Calibration Due Date ................................................................................................................................................ 45
Verification ................................................................................................................................................................ 46
Calibrating Using the IR Link ......................................................................................................................................... 47
Event Logs......................................................................................................................................................................... 49
Datalogs ............................................................................................................................................................................. 49
Bump and Calibration Results......................................................................................................................................... 50
Downloading Datalogs and Event Logs ......................................................................................................................... 50
Software Requirements ................................................................................................................................................. 50
Maintenance ...................................................................................................................................................................... 51
Maximum Hose Length for Sampling ............................................................................................................................. 51
Battery Maintenance and Cautions ................................................................................................................................ 51
Charging the Battery ...................................................................................................................................................... 52
Optimum Battery Operation ...................................................................................................................................... 53
Replacing the Battery..................................................................................................................................................... 53
Replacing a Sensor or Sensor Filter .............................................................................................................................. 53
Replacing the Pump Filters............................................................................................................................................ 57
Replacing the Pump....................................................................................................................................................... 59
Troubleshooting................................................................................................................................................................ 60
Replacement Parts and Accessories .............................................................................................................................. 63
Specifications.................................................................................................................................................................... 65

GasAlertMax XT II
Technical Reference Guide
Title Page
General Datalogger Specifications ................................................................................................................................ 67

List of Figures
Figure Title Page
1. Parts of the GasAlertMax XT II............................................................................................................................. 7
2. Display Elements.................................................................................................................................................. 8
3. Connecting the IR Link ....................................................................................................................................... 20
4. Device Configuration Section ............................................................................................................................. 21
5. Sensor Configuration Tab (H2S) ........................................................................................................................ 26
6. Connecting the Gas Cylinder to the Detector..................................................................................................... 42
7. Calibrate Device Dialog Box............................................................................................................................... 47
8. Connecting the Charger Adapter........................................................................................................................ 52
9. Replacing a Sensor or Sensor Filter .................................................................................................................. 55
10. Front and Rear Shells Side by Side ................................................................................................................... 56
11. Remove the O2Sensor With a Scredriver.......................................................................................................... 56
12. Replacing the Pump Filters ................................................................................................................................ 58
13. Removing the Pump Filters ................................................................................................................................ 58
14. Troubleshooting.................................................................................................................................................. 60

List of Tables
Table Title Page
1. Gases Monitored .................................................................................................................................................. 2
2. International Symbols ........................................................................................................................................... 5
3. Parts of the GasAlertMax XT II............................................................................................................................. 7
4. Display Elements.................................................................................................................................................. 8
5. Pushbutton ........................................................................................................................................................... 9
6. Connecting the IR Link ....................................................................................................................................... 20
7. Alarms ................................................................................................................................................................ 32
8. Computed Gas Exposures ................................................................................................................................. 35
9. Gas Alarm Setpoints .......................................................................................................................................... 36
10. Sample Factory Alarm Setpoints ........................................................................................................................ 37
11. Connecting the Charger Adapter........................................................................................................................ 52
12. Replacing a Sensor or Sensor Filter .................................................................................................................. 54
13. Replacing the Pump Filters ................................................................................................................................ 57
14. Replacement Parts and Accessories ................................................................................................................. 63

1
GasAlertMax XT II
Introduction
a Warning
To ensure personal safety, read Safety Information -
Read First and aCautions before using the detector.
The GasAlertMax XT II gas detector (“the detector”) warns of
hazardous gas at levels above user-defined alarm setpoints.
The detector is a personal safety device. It is your respons bility
to respond properly to the alarm.

GasAlertMax XT II
Technical Reference Guide
2
Gases Monitored
The following table lists the gases that are monitored by the detector.
Table 1. Gases Monitored
CAUTION: FOR SAFETY REASONS, THIS EQUIPMENT MUST BE
OPERATED AND SERVICED BY QUALIFIED PERSONNEL ONLY.
READ AND UNDERSTAND THIS TECHNICAL REFERENCE GUIDE
COMPLETELY BEFORE OPERATING AND SERVICING.
Safety Information - Read First
Use the detector only as specified in this technical reference guide,
otherwise the protection provided by the detector may be impaired.
International symbols used on the detector and in this technical
reference guide are defined in Table 2.
Read the aCautions on the following pages before using the detector.
ec Warning
This instrument contains a lithium polymer battery.
Dispose of lithium cells immediately. Do not
disassemble and do not dispose of in fire. Do not mix
with the solid waste stream. Spent batteries must be
disposed of by a qualified recycler or hazardous
materials handler.
Gas Detected Unit of Measure
Hydrogen sulfide (H2S) parts per million (ppm)
Carbon monoxide parts per million (ppm)
Combustible gases (LEL)
a) percent of lower explosive limit
(%LEL)
b) percent by volume methane
0-5.0% v/v
Oxygen (O2)% volume
Inhaltsverzeichnis
Andere BW Technologies Sicherheitssensor Handbücher

BW Technologies
BW Technologies NH3 RESPONDER Bedienungsanleitung

BW Technologies
BW Technologies GasAlertClip Extreme 2 Year Bedienungsanleitung

BW Technologies
BW Technologies GasAlert Extreme Bedienungsanleitung

BW Technologies
BW Technologies Quattro Gebrauchs- und Pflegehandbuch

BW Technologies
BW Technologies GasAlert Extreme Bedienungsanleitung

BW Technologies
BW Technologies GasAlert MicroClip XT Bedienungsanleitung

BW Technologies
BW Technologies MicroClip XT Bedienungsanleitung

BW Technologies
BW Technologies GasAlertClip Extreme SO2 Bedienungsanleitung

BW Technologies
BW Technologies GasAlertMax Bedienungsanleitung

BW Technologies
BW Technologies CONNEX1 Bedienungsanleitung