Cal Test Electronics CT2700A Bedienungsanleitung

User Manual
CT2700A
40 kV High-Voltage DMM Probe

2CT2700A 40 kV High-Voltage DMM Probe User Manual
Notices
Copywrite © 2023 Cal Test Electronics, Inc. All rights reserved.
Unauthorized duplication of this documentation material is strictly prohibited. Users are permitted to
duplicate and distribute this documentation for internal educational purposes only. Cal Test Electronics is
governed by United States and international copywrite laws.
Made in Taiwan
User Manual Part Number
451-103-001
Available in electronic format only
Published by:
Cal Test Electronics, Inc.
22820 Savi Ranch Parkway
Yorba Linda, CA 92887 USA
Warranty
LIMITED ONE-YEAR WARRANTY
Cal Test Electronics, Inc warrants these products to be free from defective material or workmanship for a
period of 1 year from the date of original purchase. Under this warranty, Cal Test Electronics, Inc is lim-
ited to repairing this product when returned to the factory, shipping charges prepaid, within the warranty
period.
Units returned to Cal Test Electronics, Inc that have been subject to abuse, misuse, damage, or accident,
or have been connected, installed, or adjusted contrary to the instructions furnished by Cal Test Electron-
ics, Inc, or that have been repaired by unauthorized persons, will not be covered by this warranty.
Cal Test Electronics, Inc reserves the right to discontinue models, change specifications, price, or design
of this device at any time without notice and without incurring any obligation whatsoever.
The purchaser agrees to assume all liabilities for any damages and/or bodily injury which may result from
the use or misuse of this device by the purchaser, his employees, or agents.
THIS WARRANTY IS IN LIEU OF ALL OTHER REPRESENTATIONS OR WARRANTIES EXPRESSED OR
IMPLIED AND NO AGENT OR REPRESENTATIVE OF CAL TEST ELECTRONICS, INC IS AUTHORIZED
TO ASSUME ANY OTHER OBLIGATION IN CONNECTION WITH THE SALE AND PURCHASE OF THIS
DEVICE.

3CT2700A 40 kV High-Voltage DMM Probe User Manual
Contents
Notices........................................................2
User Manual Part Number .........................................2
Warranty .......................................................2
Contents ......................................................3
Compliance Information...........................................4
Safety .........................................................4
EC Declaration of Conformity - Low Voltage .........................4
Environmental...................................................4
Restriction of Hazardous Substances (RoHS 2) ......................4
Terms & Symbols................................................5
Terms .........................................................5
Symbols .......................................................5
Safety Information ...............................................6
Usage Precautions...............................................6
IEC Measurement Category & Pollution Degree Definitons................7
Introduction ....................................................8
Overview.......................................................8
Supplied Accessories ............................................8
Using Accessories ...............................................9
Round Tip & Hook Tip...........................................9
Flat Bar Tip ...................................................9
Measurement Instructions .........................................10
Steps .........................................................10
Specifications ..................................................11
Cleaning.......................................................12
China RoHS 2 ..................................................13
Hazardous Substances Disclosure Table .............................13

4CT2700A 40 kV High-Voltage DMM Probe User Manual
Compliance Information
Safety
EC Declaration of Conformity - Low Voltage
Compliance was demonstrated to the following specification as listed in the Official Journal of the Europe-
an Communities: Low Voltage Directive: 2014/35/EU.
EN 61010-031:2015 Ed 2.0. Safety requirements for electrical equipment for measure-
ment, control and laboratory use - Part 031: Safety requirements for hand-held probe
assemblies for electrical measurement and test.
Environmental
Restriction of Hazardous Substances (RoHS 2)
The product and its accessories conform to the Directive 2011/65/EU (RoHS 2) on the restriction of the
use of certain hazardous substances in electrical and electronic equipment, inclusive of any modification
and addendum to said Directive.
EN ISO 63000:2018 Technical documentation for the assessment of electrical and elec-
tronic products with respect to the restriction of hazardous substances.
China RoHS 2 refers to the Ministry of Industry and Information Technology Order No.
32, effective July 1, 2015. See “Hazardous Substances Disclosure Table” on page 13.
Product End-of-Life Handling
The equipment may contain substances that could be harmful to the environment or human health if
improperly handled at the product’s end of life. To avoid release of such substances into the environment
and to reduce the use of natural resources, we encourage you to recycle this product to an appropriate
system that will ensure that most of the materials are reused or recycled appropriately.
This product is subject to Directive 2012/19/EU of the European Parliament and the
Council of the European Union on waste electrical and electronic equipment (WEEE),
and in jurisdictions adopting that Directive, is marked as being put on the market after
August 13, 2005, and should not be disposed of as unsorted municipal waste. Please
utilize your local WEEE collection facilities in the disposition of this product.

5CT2700A 40 kV High-Voltage DMM Probe User Manual
Terms & Symbols
The following terms, symbols, and definitions, individually or combination may appear on the product or in
this user manual.
Terms
A caution statement calls attention to an operating procedure, practice, or condition,
which, if not followed correctly, could result in damage to or destruction of parts or the
entire product.
A warning statement calls attention to an operating procedure, practice, or condition,
which, if not followed correctly, could result in injury or death to personnel.
A note statement calls attention to an operating procedure, practice, or condition, which,
should be noted before proceeding.
Symbols
CAUTION – Statements or instructions that must be consulted in order to find
out the nature of the potential hazard and any actions which must be taken.
WARNING - HIGH VOLTAGE - possibility of electric shock.
The Conformitè Europëenne (CE) Mark is the European Union’s (EU) mandatory
conformity marking for regulating the goods sold within the European Economic
Area (EEA).
CAUTION
WARNING
NOTE

6CT2700A 40 kV High-Voltage DMM Probe User Manual
Safety Information
Usage Precautions
The high-voltage probe is designed to prevent accidental shock to the operator when
properly used. This operating note must be read and understood prior to using the
probe. Improper procedure or incorrect analysis of the measurement situation can result
in serious shock.
This high-voltage probe must only be used by personnel who are trained, experienced,
or otherwise qualified to recognize hazardous situations and who are trained to the safe-
ty precautions that are necessary to avoid possible injury when using such a device.
This high-voltage probe is designed for use with Measurement Category other than II, III
and IV only (formally CAT I). Do not use the probe for measurements performed on cir-
cuits defined by any other measurement category or transient overvoltages of more than
1500 V. Refer to IEC Measurement Category Definitions on page 7 for a definition of
measurement categories.
The ground lead is critical to the safe operation of the probe. Failure to make this
connection when making high-voltage measurements may result in personal injury or
damage to the probe or oscilloscope. This connection must always be made BEFORE
the probe tip comes in contact with the high voltage and must not be removed until the
probe tip has been removed from the high-voltage source.
Hands, shoes, floor, and work bench must be dry. Avoid making measurements under
humidity, dampness, or other environmental conditions that might affect safety.
To avoid injury, remove jewelry such as rings, watches, and other metallic objects. Do
not touch exposed connections and components when power is present.
Do not work alone when working with high-Voltage Circuits.
The probe is designed to be used in office-type indoor environments.
• Do not operate in the presence of noxious, corrosive, flammable fumes, gases, vapors,
chemicals, or finely-divided particulates.
• Hands, shoes, floor, and workbench must be dry. Avoid making measurements under
humid, damp, or other environmental conditions that might effect the safety of the
measurement situation.
• The probe body should be kept clean and free of any conductive contamination. Refer
to the section on cleaning.
To reduce the risk of shock or fire:
• Connect the probe to the oscilloscope before connecting probe to the circuit under
test. Disconnect the probe input from the circuit before disconnecting the probe from
the oscilloscope.
• Do not exceed the voltage rating category rating of the probe. Use only accessories
provided with probe.
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING

7CT2700A 40 kV High-Voltage DMM Probe User Manual
• Keep finger behind the finger guard of the probe body.
• For your own safety, inspect the probe for cracks and frayed or broken leads before
each use. If defects are noted, DO NOT use the probe.
• Keep the probe’s output cables away from the circuit under test, as they are not
intended to be in contact with these circuits.
It is advisable to turn the high-voltage source off before connecting or disconnecting the
probe.
Do not attempt to take measurements where the source and the test instrument chassis
or return lead is not properly grounded.
Do not connect the ground clip to the high voltage source or the probe tip to the ground
for any reason.
IEC Measurement Category & Pollution Degree Definitons
Measurment Category (CAT) - classification of testing and measuring circuits according to the types of
mains circuits to which they are intended to be connected.
Measurment Category other than II, III, or IV: circuits that are not directly connected to
the mains supply.
Measurment Category II (CAT II): test and measuring circuits connected directly to ultilz-
ation points (socket outlets and similar prints) of the low-voltage mains installation..
Measurment Category III (CAT III): test and measuring circuits connected to the distribu-
tion part of a building’s low-voltage mains installation.
Measurment Category IV (CAT IV): test and measuring circuits connected at the source
of the building’s low-voltage mains installation.
Pollution - addition of foreign matter, solid, liquid, or gaseous (ionized gases) that may produce a reduc-
tion of dielectric strength or surface resistivity.
Pollution Degree 2 (P2)- only non-conductive pollution occurs except that occasionally a
temporary conductivity caused by condensation is expected.
WARNING
WARNING
WARNING

8CT2700A 40 kV High-Voltage DMM Probe User Manual
Introduction
Overview
The Cal Test CT2700A 40 kV High-Voltage Digitial Multimeter (DMM) probe can be used with anlalog or
digital multimeters (DMMs) which accept 4 mm sheathed banana plugs and have an input resistance of
10 MΩ (±1%). The CT2700A is a 1000:1 divider which extends the voltage meansurement capability to 28
kV ACrms.
Features of the probe:
• Up to 40 kV (DC + ACpeak) or 28 kV ACrms
• 300 Hz bandwidth (-3dB)
• ±3% accuracy (20 kV to 40 kV)
• IEC/EN 61010-031
Figure 1 Probe and Supplied Accessories
Supplied Accessories
Table 1 CT4432 Accessory Replacements
Accessory Model No. Quantity
Round Tip CT2960A 1
Hook Tip CT2961A 1
Flat Bar Tip CT2962A 1
4 mm Sheathed Banana
Plug Input Leads, Black
& Red
Round Tip
Hook Tip
Flat Bar Tip
Alligator Clip Ground
Lead (Fixed)
M5 Threaded
Stud

9CT2700A 40 kV High-Voltage DMM Probe User Manual
Using Accessories
Round Tip & Hook Tip
Thread either the Round Tip or the Hook Tip onto the probe’s M5 tip stud and securely hand-tighten.
Figure 2 Attaching the Round and Hook Tips
Flat Bar Tip
The end of the Flat Bar Tip can be clamped to the device-under-test (DUT). To secure the Flat Bar Tip to
the probe, use the supplied M5 flange nut (8 mm wrench or nut driver) as show in Figure 3.
Figure 3 Attaching the Flat Bar Tip

10 CT2700A 40 kV High-Voltage DMM Probe User Manual
Measurement Instructions
Before connecting the probe for your measurement, read all the warnings in this section and all of the
warnings in the section “Safety Information” on page 6.
Steps
1. Whenever possible, turn off the high-voltage source before making any connections.
2. Connect the alligator ground clip lead to a good earth ground or reliable chassis ground.
3. Connect the probe’s 4 mm sheathed banana plugs to the DMM’s input jacks; Red to voltage jack and
Black to COM jack.
4. On the DMM, select the voltage range.
Do not use autoranging.
Before turning on the high voltage source, make sure that no part of the person holding
the probe is touching the device under test.
5. After confirming that the probe operator is not touching the device under test, turn on the high-volt-
age source.
6. Measure the voltage readout on the DMM.
Remember the actual voltage is 1000 times greater than the DMM reading.
7. Turn off the high voltage source.
8. Disconnect the probe tip from the high-voltage source.
9. Disconnect the probe’s ground clip lead.
Disconnect the probe tip from the high voltage source BEFORE disconnecting the alliga-
tor ground clip lead.
CAUTION
WARNING
WARNING
WARNING
Inhaltsverzeichnis
Andere Cal Test Electronics Prüfgeräte Handbücher
Beliebte Prüfgeräte Handbücher anderer Marken

SMART
SMART KANAAD SBT XTREME 3G Series Bedienungsanleitung

Agilent Technologies
Agilent Technologies BERT Serial Bedienungsanleitung

Agilent Technologies
Agilent Technologies N3280A Bedienungsanleitung

Vernier
Vernier Go Direct Voltage Bedienungsanleitung

Lifeloc
Lifeloc R.A.D.A.R. Bedienungsanleitung

Fluke
Fluke T5-600 Bedienungs- und Montageanleitung

PCB Piezotronics
PCB Piezotronics 8159-0112A Bedienungsanleitung

BW Technologies
BW Technologies MicroDock II Bedienungsanleitung

Sun Nuclear
Sun Nuclear 1027 Bedienungsanleitung

Biomark
Biomark HPR LITE READER Bedienungsanleitung

Hioki
Hioki 3169-20 Bedienungsanleitung

Ashcroft
Ashcroft ATE-100 Bedienungsanleitung