Campbell CM110 Bedienungsanleitung

Tripod Installation Manual
Models CM110, CM115, CM120
Revision: 3/12
Copyright © 2005-2012
Campbell Scientific, Inc.


Warranty
“PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are
warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in
materials and workmanship under normal use and service for twelve (12)
months from date of shipment unless otherwise specified in the corresponding
Campbell pricelist or product manual. Products not manufactured, but that are
re-sold by Campbell, are warranted only to the limits extended by the original
manufacturer. Batteries, fine-wire thermocouples, desiccant, and other
consumables have no warranty. Campbell's obligation under this warranty is
limited to repairing or replacing (at Campbell's option) defective products,
which shall be the sole and exclusive remedy under this warranty. The
customer shall assume all costs of removing, reinstalling, and shipping
defective products to Campbell. Campbell will return such products by surface
carrier prepaid within the continental United States of America. To all other
locations, Campbell will return such products best way CIP (Port of Entry)
INCOTERM® 2010, prepaid. This warranty shall not apply to any products
which have been subjected to modification, misuse, neglect, improper service,
accidents of nature, or shipping damage. This warranty is in lieu of all other
warranties, expressed or implied. The warranty for installation services
performed by Campbell such as programming to customer specifications,
electrical connections to products manufactured by Campbell, and product
specific training, is part of Campbell’s product warranty. CAMPBELL
EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Campbell is not liable for any special, indirect,
incidental, and/or consequential damages.”

Assistance
Products may not be returned without prior authorization. The following
contact information is for US and international customers residing in countries
served by Campbell Scientific, Inc. directly. Affiliate companies handle
repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company serves
your country.
To obtain a Returned Materials Authorization (RMA), contact CAMPBELL
SCIENTIFIC, INC., phone (435) 227-9000. After an applications engineer
determines the nature of the problem, an RMA number will be issued. Please
write this number clearly on the outside of the shipping container. Campbell
Scientific's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784
For all returns, the customer must fill out a "Statement of Product Cleanliness
and Decontamination" form and comply with the requirements specified in it.
The form is available from our web site at www.campbellsci.com/repair. A
completed form must be either emailed to repair@campbellsci.com or faxed to
(435) 227-9106. Campbell Scientific is unable to process any returns until we
receive this form. If the form is not received within three days of product
receipt or is incomplete, the product will be returned to the customer at the
customer's expense. Campbell Scientific reserves the right to refuse service on
products that were exposed to contaminants that may cause health or safety
concerns for our employees.

Tripod Installation Table of Contents
PDF viewers: These page numbers refer to the printed version of this document. Use the
PDF reader bookmarks tab for links to specific sections.
1. General .........................................................................1
2. Specifications ..............................................................2
3. Tools List (for tripod, mast and crossarm) ...............3
4. Tripod Components.....................................................3
5. Tripod Installation........................................................4
5.1 Tripod Base...............................................................................................4
5.2 Mast ..........................................................................................................5
5.3 Installing the Guy Kit ...............................................................................9
5.3.1 Guy Duckbill Anchor Kits ............................................................11
5.3.2 Lowering Mast after Attaching Guy Wires...................................13
5.4 Staking the Tripod Feet ..........................................................................14
5.5 Tripod Grounding ...................................................................................15
5.6 Crossarm Attachment .............................................................................17
5.7 Enclosure Attachment.............................................................................17
5.7.1 Enclosure Mounting to Tripod Mast.............................................17
5.7.2 Enclosure Mounting to Tripod Leg...............................................18
6. Mounting Brackets ....................................................20
6.1 CM210 Crossarm Mounting Kit.............................................................20
6.2 CM216 Mast Mounting Kit ....................................................................21
6.3 CM220 Right Angle Mounting Kit.........................................................22
6.4 CM225 Pyranometer Mounting Stand....................................................23
6.5 CM230 Adjustable Angle Mounting Kit ................................................24
6.6 CM235 Magnetic Mounting Stand .........................................................25
6.7 RM Young Gill Radiation Shields..........................................................26
Appendix
A. Tripod Tote Bag....................................................... A-1
Figures
1-1. Typical tripod-based weather station.......................................................1
2-1. 60-degree guy angle ................................................................................3
4-1. Tripod components..................................................................................4
5-1. Tripod leg, slide collar components ........................................................5
i

Tripod Installation Table of Contents
ii
5-2. Tripod mast and insert ............................................................................ 6
5-3. Mast attachment to tripod base ............................................................... 7
5-4. Mast lock bracket.................................................................................... 8
5-5. Guy collar ............................................................................................... 9
5-6. Guy cinch and lever arm....................................................................... 10
5-7. Mechanical drawing of guy hook and case........................................... 11
5-8. Duckbill guy anchor ............................................................................. 12
5-9. Top view and guy anchor layout .......................................................... 13
5-10. Staking the tripod feet......................................................................... 14
5-11. Ground rod and clamp ........................................................................ 15
5-12. Lightning rod and tripod grounding lug ............................................. 16
5-13. CM204 Crossarm................................................................................ 17
5-14. Enclosure with the –MM Bracket....................................................... 18
5-15. Enclosure with the –LM Bracket........................................................ 19
6-1. CM210 Crossarm Mounting Kit........................................................... 20
6-2. CM216 Mast Mounting Kit .................................................................. 21
6-3. CM220 Right Angle Mounting Kit....................................................... 22
6-4. CM225 Pyranometer Mounting Stand.................................................. 23
6-5. CM230 Adjustable Angle Mounting Kit .............................................. 24
6-6. CM235 Magnetic Mounting Stand ....................................................... 25
6-7. RM Young Gill Radiation Shield ......................................................... 26

Tripod Installation Manual
Models CM110, CM115, CM120
1. General
The CM110 (10 feet), CM115 (15 feet), and CM120 (20 feet) tripods are
corrosion-resistant stainless steel instrument mounts that support the
attachment of sensors, solar panels, and environmental enclosures. A guy kit is
included with the CM115 and CM120 models, and is an option for the CM110.
A durable Tripod Tote Bag is available as an option.
FIGURE 1-1. Typical tripod-based weather station
1

Tripod Installation Manual Models CM110, CM115, CM120
2. Specifications
CM115 (see note 3) CM120 (see note 3)CM110
Height w/mast insert: 10’ (3 m) 15.5’ (4.7 m) 21.0’ (6.4 m)
Weight: 34 lbs (15 kg) 40 lbs (18 kg) 46 lbs (21 kg)
Base diameter w/legs extended: 7 ft (2 m) 7 ft (2 m) 7 ft (2 m)
Dimensions of collapsed tripod: 6” x 6” x 57”
(15 x 15 x 145 cm)
6” x 6” x 57”
(15 x 15 x 145 cm)
6” x 6: x 57”
(15 x 15 x 145 cm)
Vertical load limit: 100 lb (45 kg) 100 lb (45 kg) 100 lb (45 kg)
Mast description
Number of sections: 1 2 3
Length: 4.6’ (1.4m) 9.3’ (2.8 m) 14.0’ (4.3 m)
Length w/insert: 8.6’ (2.6 m) 13.3’ (4.1 m) 18.0’ (5.5 m)
OD: 1.9” (4.8 cm) 1.9” (4.8 cm) 1.9” (4.8 cm)
Insert OD: 1.75” (4.45 cm) 1.75” (4.45 cm) 1.75” (4.45 cm)
Mounting hole in tripod foot: 0.75” diameter hole
for user-supplied
0.5” J-bolts
0.75” diameter hole
for user-supplied
0.5” J-bolts
0.75” diameter hole
for user-supplied
0.5” J-bolts
Wind load recommendations
Sustained wind (mph): *75 (unguyed)
80 (guyed at feet)
*56.25 (guyed at feet)
75 (guyed at 60°)
*42.25 (guyed at feet)
65 (guyed at 60°)
Gust tolerance (mph): 95 (unguyed)
100 (guyed at feet)
71.25 (guyed at feet)
95 (guyed at 60°)
55.25 (guyed at feet)
85 (guyed at 60°)
Tote bag dimensions: 8” (20 cm) diameter,
60” (152 cm) length
8” (20 cm) diameter,
60” (152 cm) length
8” (20 cm) diameter,
60” (152 cm) length
2

Tripod Installation Manual Models CM110, CM115, CM120
60º
60º
*Anchors must hold at least
400 lbf in both x, y axis
FIGURE 2-1. 60-degree guy angle
3. Tools List (for tripod, mast and crossarm)
1/2” and 7/16” open end wrenches
adjustable wrench
socket wrench with 1/2”and 7/16” deep sockets (optional)
Phillips head screw driver (medium)
Straight bit screwdriver (large)
12” torpedo level
side-cut pliers
pencil
tape measure
compass and site declination angle
shovel
sledge hammer (for driving ground rod and stakes)
step ladder
4. Tripod Components
Figure 4-1 shows the tripod components packaged for shipment. The tripod
base is packaged with the mast, ground rod, lightning rod and (6) stakes. The
ground rod clamp, lightning rod, and grounding wires are enclosed in a bag.
The guy kit (optional for the CM110), and tripod tote bag (optional) are
packaged separately. The CM115 and CM120 tripods include additional mast
sections. A diagram showing how to stow the components inside the tote bag
is shown in Appendix A.
3

Tripod Installation Manual Models CM110, CM115, CM120
FIGURE 4-1. Tripod components
5. Tripod Installation
5.1 Tripod Base
Tripod installation near power lines is dangerous. The
minimum safe recommended distance from overhead
power lines is 2 times the height of the tripod and mast
combined. Call Blue Stakes to locate buried utilities
prior to installation.
WARNING
All three models of tripods use the same tripod base. Each leg is adjustable,
which allows the tripod to be adjusted for non-level terrain.
Prepare the area where the tripod will be installed. The tripod requires an area
approximately 7 feet in diameter. Natural vegetation and the ground surface
should be disturbed as little as possible, but brush and tall weeds should be
removed.
Stand the tripod base up on end, and rotate the feet perpendicular to the legs.
Each leg has a slide collar and T-knob with a spring loaded pin that locks into
holes located on the underside of the leg as shown in Figure 5-1.
Extend each leg until the pin engages in a hole (depress the tab to disengage
the pin from a hole). With the legs extended, orient the tripod so that the open
channel of the tripod base faces North. The tripod is typically plumbed after
the mast has been installed, as described in Section 5.2.
4
Andere Handbücher für CM110
4
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Campbell Kamerazubehör Handbücher

Campbell
Campbell CM106 Bedienungsanleitung

Campbell
Campbell 30066 Betriebsanleitung

Campbell
Campbell CM106B Bedienungsanleitung

Campbell
Campbell CM106K Bedienungsanleitung

Campbell
Campbell CM106BE Bedienungsanleitung

Campbell
Campbell CM106 Bedienungsanleitung

Campbell
Campbell CM10K Bedienungsanleitung

Campbell
Campbell CM110 Bedienungsanleitung

Campbell
Campbell CM110 Bedienungsanleitung

Campbell
Campbell CM110 Bedienungsanleitung