Cardax Prox Plus Mifare Kurzanleitung

Part number 3C4480 R10 1
May 2005
Installation Note
Cardax Prox Plus Mifare
Reader
CAUTION
This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment
are earthed before beginning any servicing.
Before you begin
Unpack the Prox Plus Mifare reader and check that you received the
following items:
1 x Base plate
1 x Reader assembly
1 x Interconnect board
1 x Four-pin Molex 6471 crimp-terminal socket equipped with
grommet and 400 mm flexible cord

2 Part number 3C4480 R10
May 2005
4 x Self-tapping pan-head screws
4 x 10 mm plastics screw caps
1 x M4 x 12 tamper-resistant Torx-head machine screw
Power supply requirements
Each Prox Plus Mifare reader consumes 200 mA from a 13.6 V
± 15% DC supply.
Use a linear-regulator power source.
Note:
Switch mode power supplies are not recommended as they may
reduce the read range of the Prox Plus Mifare reader.
Firmware
The reader firmware has two variants. These are set out in the
table.
Firmware identification Capability
vR1.06 and earlier Reads Philips Mifare 1K cards.
vR2.05 and later Reads Philips Mifare 1K cards
Reads all sectors of Philips Mifare 4K cards
Depending on the type of firmware, there is a difference in the
sequence displayed on the reader's screen after power has been
applied.

Part number 3C4480 R10 3
May 2005
vR1.nn vR2.nn
After power has been applied,
the reader:
Beeps
Displays each of its icons in
sequence
Displays the secure icon .
After power has been applied,
the reader:
Beeps
Displays each of its icons in
sequence
Displays each of its icons in
sequence a second time
Displays all icons
simultaneously
Displays a blank screen for
about two seconds
Displays the secure icon .
The version of firmware used by the reader is shown on a label
attached to the central processor integrated circuit. The diagrams
below show the location of the label for both variants of the reader.
(MFCM 200)
(MFRC500)

4 Part number 3C4480 R10
May 2005
Cabling
The Prox Plus Mifare reader uses the Cardax IV communications
system. It can be connected to the following equipment:
Cardax FT Controller 3000
Cardax FT Reader I/O Interface
Cardax FT URI
Use 4 core, 0.2 mm² (AWG 24) cabling with a maximum nominal
capacitance of 120 pF/m.
With this type of cable, the maximum distance between the Prox
Plus Mifare reader and the device to which it connects is 200 m
(650 ft).
Distance between proximity readers
The distance separating any two proximity readers must not be less
than 200 mm in all directions.
200 mm

Part number 3C4480 R10 5
May 2005
When mounting a proximity reader on an internal wall, check that
any reader fixed to the other side of the wall is not less than
200 mm away.
Attaching the base plate
Note:
The Prox Plus Mifare reader has been designed to metric
specifications. Any imperial measurements shown in this document
are approximate.
The Prox Plus Mifare reader is designed to be mounted on any solid
flat surface including metal surfaces.
The recommended mounting height for the Prox Plus Mifare reader
is 1100 mm from floor level to the centre of the reader device.
However this may vary in some countries and you should check
local regulations for variations to this height.
Drill a 20 mm (3/4 inch) diameter hole for the base extrusion
through or into the mounting surface to a minimum depth of 40 mm
(1½ inches).
Run the building cabling through the base.

6 Part number 3C4480 R10
May 2005
Press the base extrusion into the 20 mm (3/4 inch) hole and secure
the base to the mounting surface using the four fixing screws.
Fit the screw caps over each fixing screw. The screw caps prevent
water from entering the reader via the fixing holes. The caps must
be installed for the Prox Plus Mifare reader to comply with the
environmental specification.
Note:
It is very important that the base of the reader is flush with and tight
against the mounting surface. If you are mounting the Prox Plus
Mifare reader on a rough surface you should make the surface as
smooth as possible under the reader and up to 25 mm (1 inch)
around the reader.
Note:
The grommet through which the cables feed into the base of the
Prox Plus Mifare reader helps to keep the device waterproof.

Part number 3C4480 R10 7
May 2005
Connections
1
2
3
4
FT CONTROLLER 3000;
FT READER I/O INTERFACE; OR
FT URI
WHITE
BLUE
RED
BLACK
(VIEWED FROM
CABLE SIDE OF SOCKET)
4321
1
2
3
4
1
2
3
4
+12V
DATA OUT
DATA IN
-12V
MOLEX 6471
CRIMP TERMINAL SOCKET
(VIEWED FROM
CABLE SIDE OF CONNECTOR)
INTERCONNECT BOARD
1234
(VIEWED FROM
READER SIDE OF CONNECTOR)
INTERCONNECT BOARD
12 34
READER
You can connect the building cable to the reader in either of two
ways:
use the four-pin socket and cord supplied with the reader and
join the cord to the building cabling; or
provide your own Molex 6471 crimp terminal socket and
terminate the building cable directly to it.
In either case, ensure that you use the socket grommet supplied with
the reader.
If you supply your own socket, use the cable terminating tool. The
tool has a head (Part No. C861145) and handle (Part No. C861115).
Pin number 4 of the socket feeds into the cable terminating tool
first.
The other end of the building cable connects to one of the
following:
Cardax FT Controller 3000
Cardax FT Reader I/O Interface
Cardax FT URI

8 Part number 3C4480 R10
May 2005
Connecting to the Cardax FT Controller 3000
The Cardax FT Controller 3000 interfaces the following types of
reader into the Cardax FT Command Centre system:
Cardax IV readers, including Prox Plus Mifare readers
Wiegand readers
Each Cardax FT Controller 3000 can interface up to eight Prox Plus
Mifare readers into the Cardax FT Command Centre system.
The ports to which the Prox Plus Mifare reader can connect are set
up as four distinct groups (numbered 1 to 4). Each group provides
connection for two Prox Plus Mifare readers or other Cardax IV
readers. Refer to the following diagram for the location of the ports
on the Cardax FT Controller 3000.
P4
P3
P1
P2
P4
PF4
PF3
PF2
PE4
PE3
PE2
PF1 PE1
DETECTOR
LED
RS485
PA4
PA3
PA2
PA1
PA4
POWER
OUT
PA3
POWER
OUT
PA2
POWER
OUT
PA1
POWE R
OUT
PB4
PB3
PB2
PB1
PC4
PC3
PC2
PC1
PD4
PD3
PD2
PD1
PC1
PC2
PC3
PC4PD4
PD3
PD2
PD1
PA1 to PA4
Power Out
pin 1 = power out
pin 2 = 0 V
Group 4
Group 3
Group 2
Group 1
PB1 to PB4
2 x Cardax IV Readers
per connector
Reader 1 = pins 1 & 3
Reader 2 = pins 2 & 4
Pin 1 = Reader 1 transmit
Pin 2 = Reader 2 transmit
Pin 3 = Reader 1 receive
Pin 4 = Reader 2 receive
J1 to J4
RS485
terminating resistors
PC1 to PC4
Inputs
pin 1 = Input 1
pin 2 = Ground
pin 3 = Input 2
Make the connections from the Prox Plus Mifare reader to the
Cardax FT Controller 3000 as shown:

Part number 3C4480 R10 9
May 2005
Controller 3000
PA
Group (x4)
PB1 and PA1... to... PB4 and PA4
4 3 2 1 2 1
PB
Prox Plus Mifare
Reader 1
Prox Plus Mifare
Reader 2
Note:
Within each group, you cannot mix Cardax IV readers with
Wiegand Readers. This is because connecting one Wiegand reader
requires all four pins on plug PB. For example, if you connect a
Prox Plus Mifare reader to Port 1 of Group 1, Port 2 of Group 1 can
only connect to another Cardax IV reader.
The terminating resistors (J1 for Group 1, J2 for Group 2, etc.) must
NOT be fitted for those groups to which Prox Plus Mifare readers
are connected.
Connecting to the Cardax FT Reader I/O Interface
The Cardax FT Reader I/O Interface has connections for up to
sixteen Prox Plus Mifare readers or other Cardax IV readers.
The Prox Plus Mifare reader connects to either plug PA or PB in
Groups 1 to 8.
Make the connections from the Prox Plus Mifare reader to the
Reader I/O interface as shown:

10 Part number 3C4480 R10
May 2005
Prox Plus Mifare Readers
Reader I/O Interface
4
3
2
1Red
White
Blue
Black
Reader A
(PA)
IN
OUT
Power
(PD)
+V
0
Group (x8)
4
3
2
1Red
White
Blue
Black
Reader B
(PB)
IN
OUT
For the location of the plugs on the Reader I/O Interface, refer to
the component layout diagram:
Inhaltsverzeichnis
Andere Cardax Kartenleser Handbücher
Beliebte Kartenleser Handbücher anderer Marken

Rosslare
Rosslare DR-6255 Bedienungsanleitung

Lindy
Lindy 51541 Bedienungsanleitung

Diapro T?bbi Ürünler
Diapro T?bbi Ürünler Across System Bedienungsanleitung

Johnson Controls
Johnson Controls Kantech tyco ioSmart Bedienungsanleitung

ACS
ACS ACR122L Bedienungsanleitung

Secukey
Secukey S2-MF Bedienungsanleitung