CBS ArcSafe RSK-CS01W Bedienungsanleitung

CS01W Operating Manual
CS01W-092619 v1.0
Instruction Manual
for Wireless CS Model Remote Actuators
used on Pistol Grip Switches
Models:
RSK-CS01W
RSK-CS03W
RSK-CS04W

CS01W Operating Manual
CS01W-092619 v1.0
(intentionally left blank)

CS01W Operating Manual
CS01W-032519 v1.0
Table of Contents
1.0 Introduction…………………………………………....…………………………. 1
2.0 General Safety Information……………………………………………………... 1
2.1 Arc-Blast Hazards………………………………………………………. 2
2.2 Battery Hazards…………………………………………………….…… 2
2.3 Magnet Hazards………………………………………………………... 2
2.4 Pinch Point Hazards……………………………………………………. 3
2.5 Radio Frequency………………………………………………..………. 3
3.0 Battery & Charger Information ……………………………………………….…. 4
3.1 Installing and Removing the Battery on the CSxxW Actuator...….. 4
3.2 Replacing the Battery in the Wireless Remote Controller …….…. 5
4.0 Use and Operation of the CSxxW.……………………………………………... 5
5.0 Storage ……………………………………………………………………………. 9
6.0 Troubleshooting ………………………………………………………………….. 10
7.0 Specifications …………………………………………………………………….. 11
8.0 Warranty……. ……………………………………………………………………..12
9.0 Contacting the Manufacturer …………………………………………………… 12
ATTACHMENTS
Milwaukee Operator’s Manual M12/M18 Multi Voltage Chargers
Milwaukee Instructions for Lithium-Ion Battery Packs

CS01W Operating Manual
CS01W-092619 v1.0
1
©CBS ArcSafe. All rights reserved.
Use and Operation Instructions
CSxxW Remote Actuator for Pistol Grip Switches
1.0 Introduction
The CS models are designed to remotely operate pistol grip switches similar to the Electroswitch Series 24.
There are several CS models available depending on the switch manufacturer and model number. The
primary difference between the CS models is in the dimensions of the mounting frame. The CS model
actuators utilize the pistol grip escutcheon plate to limit the movement of the CS actuator while it is turning
the pistol grip handle. So, dimensionally, the frame must properly engage the escutcheon plate. The
CS01W is the most common model as it fits an estimated 90% of the pistol grip switches found on
switchgear. But other models are available to fit most of the remaining switches. Models are identified by
the third and fourth digits of the part number. For example, CS01W, CS03W, CS04W are various models
offered. Although each model is slightly different in the frame size, the operation and use of each is the
same. This user manual can be used for all CS models. Any reference to CSxxW means the actual control
switch actuator. References to RSK-CSxxW means the “Remote Switching Kit” which includes the
following items necessary to operate the actuator.
Model: RSK-CSxxW
CSxxW Actuator
RTL-2 Hand-held transmitter
Milwaukee M18-CP2.0 battery
Milwaukee M18 battery charger
Instruction Manual
Pelican Carrying case
2.0 General Safety Information:
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• This equipment must only be installed by qualified personnel.
• Only use this equipment after reading and understanding all of the instructions contained in this manual.
• Follow electrical safe work practices. See NFPA 70E or CSA Z462
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DEATH OR SERIOUS INJURY

CS01W Operating Manual
CS01W-092619 v1.0
2
©CBS ArcSafe. All rights reserved.
2.1 Arc-blast Hazards
The hazards associated with electrical arc-blasts are well documented. Studies conducted by numerous
industries and professional organizations have sought to quantify the intensity of arc blast, the risks to
personnel, and various methodologies for mitigating the risks.
Without a doubt, increasing the distance between the arc and a human is the single greatest favorable
factor in reducing injuries. Remote operation of electrical equipment is not a cure-all, but rather one more
tool available for protecting workers while they are performing electrical switching.
Using the CSxxW remote operating device for motor control centers may not negate the need for additional
personal protective measures. The user is ultimately responsible for evaluating each situation to determine
if additional protective measures are needed.
2.2 Battery Hazards
The CSxxW is battery powered from a Milwaukee Tool M18 battery provided. The voltage output on the
battery is 18VDC. Although this is below the recognized threshold for a shock hazard, there can be
significant energy stored in the battery pack. See Section 3.0 for more information on the M18 battery.
The M18 Milwaukee battery contains Lithium-Ion cells. Care must be taken when handling the battery and
federal regulations must be followed when shipping the battery.
2.3 Magnet Hazards
The magnets that are used on the CxxW to hold it on the switchgear produce strong magnetic fields, so
care must be taken when handling it. The following steps should be followed to assure safe handling:
• The magnets need to be kept at a safe distance from all magnetic storage devices, electronics,
credit cards, etc.
• Do not use the CSxxW if the magnets have been damaged.
• Always keep the bottom of the magnet free of debris and rust. If needed, dirt can be removed using
the sticky side of a piece of masking tape.
THIS EQUIPMENT CONTAINS LITHIUM-ION and ALKALINE CONTAINING BATTERIES
• All Federal and State regulations must be followed for disposal, transport, and shipment of
the batteries and equipment.
• Rechargeable batteries should only be charged using chargers approved for the battery type
and manufacturer.
THIS EQUIPMENT UTILIZES POWERFUL MAGNETS TO HOLD IT ON THE SWITCHGEAR
Care must be taken to prevent injury when handling this equipment

CS01W Operating Manual
CS01W-092619 v1.0
3
©CBS ArcSafe. All rights reserved.
2.4 Pinch Point Hazards
The CSxxW is a motorized device with moving parts that will produce the opportunity for pinch point
hazards. In order to prevent a pinch point injury, the following procedures should be followed:
• Install the CSxxW actuator on the switchgear door prior to turning it on.
• Once the CSxxW is turned ON, do not touch or bring body parts near the actuator.
• Turn OFF the CSxxW actuator prior to removing it from the switchgear door.
• Do NOT attempt to turn the CSxxW actuator ON unless it is installed and ready to use.
Additionally, the magnets used to hold the CSxxW actuator on the switchgear door could present a pinch
hazard. To prevent an injury the follow procedures should be followed:
• Keep all fingers away from the magnet areas when installing.
• Follow the installation procedure in Section 4.0 when installing the CSxxW on the switchgear door.
2.5 Radio Frequency
The wireless version of the CSxxW uses a radio transmitter and receiver to communicate. The transmitter
and receiver operate in the 2.4GHz frequency band and is low power at 6.3mW. These are commercially
available radios that have agency certification through the manufacturer. They are certified with the
following agency approvals:
United States – FCC
FCC ID: MQC-XBEE3
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (i.) this device may not cause harmful interference and (ii.) this device must accept
any interference received, including interference that may cause undesired operation.
Canada – IC
IC: 1846AXBEE3
CAUTION! To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation
distance of 20 cm or more should be maintained between the antenna of this device and persons during
device operation. To ensure compliance, operations at closer than this distance are not recommended. The
antenna used for this transmitter must not be co-located in conjunction with any other antenna or
transmitter.
THIS EQUIPMENT HAS MOVING PARTS THAT PRESENT PINCH POINT HAZARDS
Care must be taken to prevent injury when handling the equipment.

CS01W Operating Manual
CS01W-092619 v1.0
4
©CBS ArcSafe. All rights reserved.
3.0 Battery and Charger Information
CSxxW Actuator Battery
The CSxxW is powered from a Milwaukee Tool M18 battery. M18 batteries are available in a variety of
sizes and capacities. The kit ships with the M18-CP2.0 battery along with a charger, but the user may use
any M18 Milwaukee battery. DO NOT ATTEMPT TO USE BATTERIES OTHER THAN THE M18
MANUFACTURED BY MILWAUKEE TOOL. DOING SO WILL VOID THE WARRANTY.
For more detailed user information for the M18 battery, see the Milwaukee Tool Safety Instructions for
Lithium-Ion Battery Packs, which is included with this manual. Additionally, SDS sheets are available for
the battery through the Milwaukee Tool website.
See Section 3.3 for information on charging the M18 battery.
Shipping of Lithium-Ion Batteries
The M18 battery cannot be shipped via air. In cases where shipping of the CSxxW by air is required, the kit
can be shipped without the battery. The M18 battery included in the kit will then be shipped separately via
ground. In the meantime, any Milwaukee M18 battery may be used. The M18 battery is very common and
you may already have one on hand. Or, you may purchase an M18 battery at a local Milwaukee Tool
supplier.
RTL-2 Remote Transmitter
The RTL-2 is a remote transmitter used with the wireless version of the CSxxW. It is powered by a 9VDC
battery. Replace this battery as needed with a commercially available 9VDC battery. An alkaline or non-
rechargeable lithium type is recommended.
3.1 Installing and Removing the Battery on the CSxxW Actuator
Installing and removing the battery on the CSxxW is easily performed by sliding the Milwaukee M18 battery
into or out of the adapter on the side of the CSxxW. The battery locks into place when properly installed
THIS EQUIPMENT USES A LITHIUM ION BATTERY PACK.
DO NOT attempt to modify the battery pack or to install a battery pack not approved for use in the CSxxW.
Doing so could cause equipment damage, fire, or personal injury.

CS01W Operating Manual
CS01W-092619 v1.0
5
©CBS ArcSafe. All rights reserved.
and can be removed by simultaneously squeezing the red colored release buttons on both sides of the
battery.
3.2 Replacing the Battery in Wireless Remote Transmitter
The RTL-2 remote transmitter uses a standard 9V battery.
To replace the battery, complete the following steps:
• Remove the battery cover on the back of the transmitter.
• Replace the battery.
• Re-install the battery cover.
3.3 Charging the M18 Battery
The M18 battery must only be charged using a charger approved by Milwaukee Tool. Included with the
CSxxW is an approved Milwaukee Tool charger. The standard part number provided is 48-59-1812,
however, some kits may ship with a different charger depending on the input voltage required. For more
detailed user information for the M18 chargers, see the Milwaukee Tool Operator’s Manual for Multi-Voltage
Chargers, which is included with this manual.
4.0 Use and Operation of the CSxxW
The CSxxW is installed over a pistol grip switch typically found on electrical switchgear. Care must be
taken when installing the CSxxW that the pistol grip switch is not inadvertently operated.
The CSxxW should be installed by tilting it downward over the switch. Attempting to install it from a
“straight on” angle will allow the magnets to pull it onto the door and likely not be aligned as it should be.
The switchgear door must be clean and free of obstacles such as labels that may prevent the magnets from
fully engaging the switchgear door. IF BOTH MAGNETS DO NOT FULLY CONTACT THE METAL OF THE
DOOR, THE ACTUATOR MAY FALL OFF DURING OPERATION.

CS01W Operating Manual
CS01W-092619 v1.0
6
©CBS ArcSafe. All rights reserved.
STEP #1 - Holding the CSxxW at an angle as shown, rest the top of the frame angle against the top of the
escutcheon plate. Then slowly rotate the actuator downward until the magnets fully engage the switchgear
door.

CS01W Operating Manual
CS01W-092619 v1.0
7
©CBS ArcSafe. All rights reserved.
STEP #2 – Install the battery.
STEP #3 – Press the WAKE button to power up the unit. The WAKE button should light indicate that power
is on. Also, the pairing LED should be lit YELLOW indicating that the radio is powered but is not yet paired
to the hand-held controller. (Pairing will not be established until the ENABLE button is pressed on the
hand-held controller).
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere CBS ArcSafe Controller Handbücher

CBS ArcSafe
CBS ArcSafe RSA-138 Betriebsanleitung

CBS ArcSafe
CBS ArcSafe RSK-ABL1 Series Bedienungsanleitung

CBS ArcSafe
CBS ArcSafe RSA-138A Betriebsanleitung

CBS ArcSafe
CBS ArcSafe RSK-SACE2 Bedienungsanleitung

CBS ArcSafe
CBS ArcSafe RSA-34 Betriebsanleitung

CBS ArcSafe
CBS ArcSafe RSA-112 Betriebsanleitung

CBS ArcSafe
CBS ArcSafe RSA-107 Betriebsanleitung

CBS ArcSafe
CBS ArcSafe RSK-AK11 Bedienungsanleitung

CBS ArcSafe
CBS ArcSafe RSK-SPB1 Bedienungsanleitung

CBS ArcSafe
CBS ArcSafe RSA-104 Betriebsanleitung