CellarPro AH6500 Bedienungsanleitung

AH6500/AH8500
HumidificationSystem

2
Congratulations on the purchase of the humidifier unit for the CellarPro Air Handler. This unit comes packaged
separately and requires some assembly and some steps to connect it to your air handler.
Package Contents
Tools Required
Humidifier
Adjustable wrench (2)
Remote humidistat with 10ft. 3 conductor leads
Phillips screw driver
10 ft. x ½” ID drain line
Screwdrivers (slotted) - #1 and #2
Self-tapping water line saddle valve
Specifications and Cut Sheets
General Description:
The CellarPro Humidifier is designed to mount directly to the evaporator module of any AH series cooling unit.
The humidifier is designed to increase the cellar humidity level above a 50% threshold where wine bottle storage
is more stable for preserving the corks. The humidifier for this unit utilizes an evaporative water pad, with a fresh
water supply line providing water to saturate an evaporative pad, which adds moisture to the cold air being
supplied to the cellar. It is intended for situations where the ambient relative humidity of the air surrounding the
cellar is insufficient to maintain the desired humidity level inside the cellar, as indicated by the shaded areas in the
chart below:
Typical Relative Humidity Range (%RH) for 55°F Cellar Temperature
without Humidifier
Ambient
Ambient Temperature °F
RH
65
70
75
80
85
90
95
10
9-14
12-17
15-20
18-23
22-27
27-32
33-38
15
16-21
20-25
25-30
30-35
37-42
44-49
50-60
20
23-28
29-34
35-40
42-47
50-60
50-60
60-70
25
30-35
37-42
44-49
50-60
50-60
60-70
60-70
30
38-43
44-49
50-60
50-60
60-70
60-70
65-70
35
44-49
50-60
50-60
60-70
60-70
65-70
65-70
40
50-60
50-60
60-70
60-70
65-70
65-70
65-70
45
50-60
60-70
60-70
65-70
65-70
65-70
65-70
50
50-60
60-70
65-70
65-70
65-70
65-70
65-70
55
60-70
60-70
65-70
65-70
65-70
65-70
65-70
60
60-70
65-70
65-70
65-70
65-70
65-70
65-70
The humidifier is controlled by a 24V remote humidistat powered from the cooling unit. The humidistat must be
mounted inside the cellar near the return air plenum inside the cellar. The humidifier operates independently from
the cooling unit, and uses the cooling unit evaporator fan to circulate the air. The factory set-point on the
humidistat is 55%RH, adjustable in 5% increments to a maximum of 70%RH.
Evaporative pad type humidifiers require a constant flow of water over the pad when the humidifier is on to keep
the water pad saturated and flush minerals and solids through to the drain. The water supply is regulated by an
internal orifice inside the humidifier, and will produce a continuous flow through to the drain line of approximately
6 gallons of water per hour during humidification. The humidifier will operate with a hot or cold water supply,
however the humidifier will operate more efficiently if supplied with hot water (140°F maximum).

3
Humidifier Specifications
Dimensions (HxWxD) 16.04"x14.82"x14.41"
Weight 28 lbs
Power Consumption 0.96 Amps @ 115V / 60Hz
Humidistat Factory Set Point 55% RH
Humidstat Set Point Range 5% to 70% RH
Humidistat Adjustment Increments 5% RH
Humidistat Display Range 0% to 95% RH
Humidistat Display Accuracy (+/-) 4.5% RH
Water Supply Feed Rate 6 gph (gallons/hour)
Nominal Water Evaporation Rate
70°F, 35%RH room
140°F water supply
0.50 gph
Cellar Water Evaporation Rate
- 55°F Air, 50%RH cellar
60°F water supply 0.09 gph
90°F water supply 0.18 gph
120°F water supply 0.30 gph

4

5

6
Installation Instructions
Step 1: Installing humidifier mounting brackets.
Install humidifier mounting brackets using #8 phillips head sheet metal screws. From the box of accessories
remove three brackets and the screws. The three brackets get mounted onto the Evaporator Module as shown
(left side facing air intake). Please make sure to mount the unit on the cold side, which is marked and on the side
opposite the controls. The brackets will form a sleeve for the humidifier to slide into. Locate the humidifier power
supply leads: black lead "80" and white lead "81". These leads will be pulled through the humidifier and
connected later in the process.
Step 2: Preparing the humidifier module for mounting.
From the humidifier in the box remove the humidifier access cover, internal screen, and water panel.
Right
mounting
bracket
Left
mounting
bracket
Humidifier
power supply
leads
Bottom
mounting
bracket
Humidifier
with access
cover
removed
Internal screen
Water panel
Important: Note
orientation of
water panel.
Distribution tray
must be on top
when reinstalled.

7
Step 3: Mounting the humidifier module onto the Air Handler.
Mount the large humidifier module to the evaporator module by sliding into the mounting brackets and secure with
the #8 phillips head sheet metal screws that are provided.
- Remove backing
from double sided
tape on humidifier top
inside flange
- Slide humidifier into
mounting brackets
until flush with
evaporator module
- Attach (1) screw
through the inside top
panel of the handler
to the humidifier top
flange
- Attach screws
through left and right
mounting brackets
to humidifier
housing, (4) screws
per bracket.

8
Step 4: Making the electrical connection to the Air Handler.
Connect humidifier power leads - black "80" to black, white "81" to white. Secure with cord clamp.
Step 5: Connecting the water supply to the humidifier.
Install 1/4" copper water line using compression fitting and flare nut to the water connection on the bottom of the
humidifier. Install humidifier drain line by sliding 1/2"ID flex tubing onto drain connection stub.
Power leads
from
humidifier
Feed power leads
from evaporator
module through to
back of humidifier and
plug into power leads
from humidifier.
Plug in
male/female
cord
connectors
Flare nut
Compression
fitting
1/4" water
supply line
Drain hose
connection stub.
Slip fit using 1/2"ID
flexible drain
tubing. Do not use
hose clamps as
they will damage
the coupling.

9
Use two wrenches when tightening water line to avoid damage to the internal water solenoid valve.
Step 6: Setting up the excess humidifier water drain.
The humidifier filter pad will have a continuous supply of excess water which will flow out of the drain. The
diagram below shows how the drain should be located for the various configurations.
Wrench to
tighten
bottom nut
Wrench
inside to
keep
solenoid
valve from
spinning

10
Step 7: Re-assemble the humidifier components.
Place the water panel back into the humidifier. Make sure the water discharge tube inserts into the water panel
top opening, and the water panel bottom drain is aligned with the housing drain. Replace the internal screen and
humidifier access cover.
Step 8: Mount and connect the humidistat.
Mount the remote humidistat inside the cellar near the return air plenum, at a convenient height to access the
display. Loosen the cover screw and separate the front housing from the base:
- Run the humidistat
lead wire through the
back hole to the
terminals.
- Install the mounting
plate using two wall
mounting screws.
- Connect wiring by
matching the wire lead
color to the terminals as
shown.
- Replace the cover.
Step 9: Getting started.
Power up the unit and set the humidistat to turn the humidifier on, and verify that water is flowing through to the
drain. The humidifier is now ready to put into service.
Cover screw
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis