CEM DT-157 Bedienungsanleitung

Coating Thickness Tester
User Manual
Group4
FE DEL
(44)
Group4
FE DEL
(44)

3
Coating Thickness Tester User Manual
Contents
1. General Information ............................................................
1-1. Application ...................................................................1-
1-2. Description of the Gauge...............................................1-
1-3. Supply Schedule.............................................................1-
1-4. Probe.............................................................................1-
1-5. Specifications.................................................................1-
1-6. Front View......................................................................1-
1-7. LCD Display....................................................................1-
2. Ready to start.......................................................................
2-1. Power Supply..................................................................1-
2-2. Replacing the Battery.....................................................1-
2-3. Menu System and Basic Settings....................................1-
3. Settings................................................................................
3-1. Unit Setting....................................................................1-
3-2. Backlight Setting............................................................1-
3-3. Auto Power Off..............................................................1-
3-4. Turn on/off Bluetooth.....................................................1-
3-5. Adjust gray scale (contrast)............................................1-
4. System Information..............................................................
4-1. System version number and gauge serial 1-
number display..............................................................1-4-1.
4-2. Data View......................................................................1-
5. Calibration and Measurement..............................................
6. Zero-point calibration of Fe or Non-Fe .................................
7. Delete Fe or Non-Fe Zero-point.............................................
8. Delete Functions...................................................................
9. Trouble Shooting..................................................................
Page
4
5
5
5
5
6
7
7
8
8
8
8
9
9
9
10
10
11
11
11
11
12
12
12
13
13

4
Coating Thickness Tester User Manual
1. General Information
The coating thickness gauges work either on the magnetic induction
principle or on the eddy current principle, depending on the type
of probe used. You can select the type of probe via MENU system,
or it will work automatically.
Features
• Measured Coatings: Non-magnetic coatings (e.g. paint, zinc)on steel;
Insulating coatings(e.g. paint, anodizing coatings)on no-ferrous metals•
• Operating with MENU easily
• Memory for 2500 readings
• Delete single readings and all group readings easily
• Error indication
• Data transferred to PC via Bluetooth for analysis
• Disable Auto-Power-off function via MENU setting

5
Coating Thickness Tester User Manual
1-1. Application
• This compact and handy gauge is designed for non-destructive, fast
and precise coating thickness measurements. The principal applications
lie in the field of corrosion protection. It is ideal for manufacturers
and their customers, for offices and specialist advisers, for paint shops
and electroplaters, for the chemical, automobile, shipbuilding and
aircraft industries and for light and heavy engineering.
• The coating thickness gauge is suitable for laboratory, workshop
and outdoor use.
• The probe can work on both principles, magnetic induction and on
the eddy current principle. One probe only is required for coating
measurement both on ferrous and non-ferrous metal substrates.It is
adaptable to specific tasks: i.e. they can be used on special geometries
or on materials with special properties.
1-2. Description of the Gauge
• For measurement on steel substrates, the gauge works on the magnetic
induction principle, for measurement on non-ferrous metal substrates,
it works on the eddy current principle.
• Measured values and user information are shown on LCD. The display
with backlight ensures easy reading of screen data in dark conditions.
1-3. Supply Schedule
Gauge with two AAA 1.5V batteries, plastics carrying case, operating
instructions (English), steel and aluminum substrate, and standard flake
for calibration.
1-4. Probe
The Probe systems are spring-mounted in the probe sleeve. This
ensures safe and stable positioning of the probe and constant contact
pressure.
A V-groove in the sleeve of the probes facilitates reliable readings
on small cylindrical parts. The hemispherical tip of the probe is made
of hard and durable material. Hold the probe by the spring mounted
sleeve and put on measuring object.

6
Coating Thickness Tester User Manual
1-5. Specifications
Sensor probe
Working principle
Measuring range
Guaranteed tolerance
(of reading)
Precision
Minimum curvature
radius
Diameter of
Minimum area
Minimum measurable
thickness
Overload display
Working temperature
Working relative
humidity
F
Magnetic induction
0~2000µm
0~78.7mils
0 ~ 1000 um
(±2%±2um)
1000~ 2000 um
(±3.5%)
0~39.3mils
(±2%±0.08 mils)
39.3~78.7mils
(±3.5)
0~100um (0.1um)
100um~1000um
(1um)
1000um~2000um
(0.01mm)
0~10mils
(0.01 mils)
10~78.7mils
(0.1 mils)
1.5mm
7mm
0.5mm
---
0°C~40°C
(32°F~104°F)
20%~90%
N
Eddy current principle
0~2000µm
0~78.7mils
0 ~ 1000 um
(±2%±2um)
1000~ 2000 um
(±3.5%)
0~39.3mils
(±2%±0.08 mils)
39.3~78.7mils
(±3.5)
0~100um (0.1um)
100um~1000um
(1um)
1000um~2000um
(0.01mm)
0~10mils
(0.01 mils)
10~78.7mils
(0.1 mils)
3mm
5mm
0.3mm
—

7
Coating Thickness Tester User Manual
1-6. Front View
1-LCD display
2- Power ON/OFF key
3-Left Key: For choose and OK
4-Up key: For upward selection and working mode switch
5-Right Key: For return or delete the last measured data
6-Down key: For downward selection or working mode switch
7-Probe
8- Lanyard hole
9-Battery cover
1-7. LCD Display
1-Working mode
2-Auto measure mode
3-Bluetooth indication
4-Ferrous or No-ferrous
metals being measured. 9-
It will change automatically 9-
in the Auto measure mode,9-
5-Measured data quantity in
the working mode9-
6-Battery indication
7-Measure data
8-Unit
9-Delete data, press right button
to delete the current data9-
8
9
1
2
3 5
6
4
Group4
FE DEL
(44)
1
2
3
4
6
8
7
9
5

8
Coating Thickness Tester User Manual
2. Ready to start
2-1. Power Supply
For power on, please press and hold button. If no LCD display:
please check if the battery is correctly installed or it is in low battery.
Display: Please replace battery immediately.
Note that the gauge will make faulty measurements if the voltage
is very low.
Note: When power on, please away from any metal at least 10 cm
above
Before each measurement, zero calibration is recommended.
2-2. Replacing the Battery
• Power off the meter.
• Open the battery cover.
• Remove battery.
• Insert new battery.
• Close the battery cover.
Caution: Make sure the anode and cathode are correctly positioned.
2-3. Menu System and Basic Settings
Press to power on; the gauge will work in measuring mode.
Press left button into MENU mode. See following MENU system
arrangement:
2-3-1. Function and operation instruction
2-3-1-1. Select Working mode
Working mode: There are 51 working modes in this gauge. Measure
data would not be stored in the gauge in Group0 measure mode.
In the other 50 working modes, 50 measured data can be stored
in each mode in cycle.
• Press left button to enter the menu
• Press Up/down button to select working mode
• Press left button to enter working mode
• Press up/down button to select working mode
• Press left button for OK.

9
Coating Thickness Tester User Manual
2-3-1-2. select measure mode (Probe)
The probe can work in three modes:
AUTO: The probe can automatically select the working mode. When
placed on steel (magnetic substrates), it will work in magnetic induction
principle. When placed on no-ferrous metals, it will work in eddy
current principle.
Fe: The probe works in magnetic induction principle.
No-Fe: The probe works in eddy current principle.
• Press left button to enter the menu
• Press Up/down button to select working mode
• Press left button to enter working mode
• Press up/down button to select working mode
• Press left button for OK.
3. Settings
3-1. Unit Setting
3-1-1. Select unit
• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select Unit
• Press left button to enter
• Press up/down button to select
• Press left button for ok
3-2. Backlight Setting
Adjust the brightness of the backlight.
• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select backlight
• Press left button to enter
• Press up/down button to adjust the brightness of the backlight
• Press right button to return.

3-3. Auto Power Off
You can disable Auto-power-off via MENU system or the gauge will
power off automatically in about 10 minutes if no measurement or
operation.
• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select Auto-power-off
• Press left button to enter
• Press up/down button to select
• Press left button for ok
3-4. Turn on/off Bluetooth
Turn on Bluetooth, data can be transferred to PC or phone or other
Bluetooth receiving device.
Turn on Bluetooth, measure data will be sent automatically via
Bluetooth. You can also download measured data via software by PC
or phone or other Bluetooth receiving device in working mode.
Note: Turn on Bluetooth, battery power will loss quickly; please do
not turn it on when there is not necessary.
When the first connection between the phone/PC and the device is
being established, a prompt for the Pin-code of the device may be
displayed. In the case, enter the code 0000 into your phone/PC.
The coating thickness gauges includes Bluetooth® wireless technology
allowing wireless data transfer to properly equipped smartphones or
tablets running iOS or Android operating systems.
Download the app to your smartphone or tablet by going to
https://play.google.com/store/apps/details?id=com.cem.ictt.activities&hl=zh_EN
10
Coating Thickness Tester User Manual

• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select Bluetooth
• Press left button to enter
• Press up/down button to select
• Press left button for ok
3-5. Adjust gray scale (contrast)
The grayscale adjustment: dot matrix LCD display may not be good
in different temperature & humidity, than you can adjust gray scale
to get good LCD display.
• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select gray scale
• Press left button to enter
• Press up/down button to adjust gray scale
• Press left button for ok
4. System Information
4-1. System version number and gauge serial number display
• Press left button to enter the menu
• Press up/down button to select the setting
• Press left button to enter the setting
• Press up/down button to select information
• Press left button to enter
• View the system information, then press right button to return.
4-2. Data View
View the stored measured data in each mode.
All-delete: Delete all measured data in group.
• Press left button to enter the menu
• Press up/down button to select view
• Press left button to enter view
• Press up/down button to select working mode
• Press left button to enter
11
Coating Thickness Tester User Manual
Inhaltsverzeichnis
Andere CEM Prüfgeräte Handbücher
Beliebte Prüfgeräte Handbücher anderer Marken

SMART
SMART KANAAD SBT XTREME 3G Series Bedienungsanleitung

Agilent Technologies
Agilent Technologies BERT Serial Bedienungsanleitung

Agilent Technologies
Agilent Technologies N3280A Bedienungsanleitung

Vernier
Vernier Go Direct Voltage Bedienungsanleitung

Lifeloc
Lifeloc R.A.D.A.R. Bedienungsanleitung

Fluke
Fluke T5-600 Bedienungs- und Montageanleitung

PCB Piezotronics
PCB Piezotronics 8159-0112A Bedienungsanleitung

BW Technologies
BW Technologies MicroDock II Bedienungsanleitung

Sun Nuclear
Sun Nuclear 1027 Bedienungsanleitung

Biomark
Biomark HPR LITE READER Bedienungsanleitung

Hioki
Hioki 3169-20 Bedienungsanleitung

Ashcroft
Ashcroft ATE-100 Bedienungsanleitung