Centrosolar S-Class Integration Deluxe Series Bedienungsanleitung

S-Class Integration Deluxe
S-Class Integration
Installation Guide
Installation Guide
S 190P50 Integration
S 195P50 Integration
S 190M50 Integration Deluxe
S 195M50 Integration Deluxe
S 190P50 Integration Deluxe
S 195P50 Integration Deluxe
903210001 - MA S-Class Integration/Integration Deluxe EN - v1.0S ME 03/2010


Installation guide
Contents
1 Notesonthisguide 2
2 SystemS-ClassIntegration(Deluxe) 2
2.1 Description 2
2.2 Tightness 2
2.3 Sub-roof 2
2.4 Dimensionaldataanddimensions 3
3 Scopeofsupply 4
3.1 Materialandtools 4
3.2 Listofmaterial 5
4 Moduleconnection-circuitryproposals 8
5 Safeinstallation 9
5.1 Preliminaryremarks 9
5.2 Installationofthemodules 12
5.3 Installationoftheroongframes 20
6 Specialcase:Installationinsteps 27
7 Commissioningofthesystem 29
8 Maintenanceandcleaning 29
9 Warrantyandguarantee 30
10 Disclaimer 30
11 Electricalparametersanddesignfeatures 31
1

Installation guide
1 Notesonthisguide
Thank you for choosing Centrosolar S-Class Integration/S-
Class Integration Deluxe modules. If you have any ques-
tions regarding the system components please contact
our technical support: +49 (0) 5251 500 500.
The maintenance and operation of a PV system require
a sound technical knowledge. Therefore, any work on the
system may only be carried out by qualied and authorized
personnel. Make sure to read these assembly instructions
carefully before installing, commissioning or servicing the
system, and store these instructions in a well accessible
location. This guide is part of the product. It is applicable
only to S-Class Integration/S-Class Integration Deluxe so-
lar modules by Centrosolar AG. Please pay special atten-
tion to the notes on the safe use of the system. Centroso-
lar is not liable for any damage resulting from disregarding
this guide.
Targetgroups
The target group of this guide, especially chapter 5 (Safe
installation) are skilled craftsmen. All relevant informa-
tion for the operator can be found in section 8 (Mainte-
nance and cleaning).
Information regarding your safety
and the protection of the device is
highlighted.
Pleasenote:
Disregarding the instructions of this installation guide may
void any warranties, guaranties and product liabilities.
2 SystemS-ClassIntegration(Deluxe)
2.1 Description
The S-Class Integration (Deluxe) mounting system replac-
es the conventional roong of pitched roofs and is used for
a roof inclination of more than 10 degrees. It is laid onto
the existing roof lathing and is suitable for old and new
buildings alike.
Due to the arrangement of the system lathing, the S-Class
Integration (Deluxe) mounting system provides for a back-
side ventilation in order to cool the modules from the back.
For the electrical connection, HUBER+SUHNER prefabri-
cated connectors are used.
2.2 Tightness
The S-Class Integration (Deluxe) mounting system offers
a rain resistance which is comparable to a standard pan-
tiled roof. It does not mean that a roof is water tight! Under
certain climatic conditions, snow akes, driving rain oder
water may penetrate under the modules from the eaves.
For a proper drainage of ingressed water or condensate,
an intact sub-roof is required. If not available, such a roof
must be erected/retrotted prior to installation of the mod-
ules.
2.3 Sub-roof
The general rules, which are valid for roofers, shall ap-
ply to the design and the backside ventilation of the sub-
roof. In order to extend the lifetime of the substructure, the
backside ventilation should be enhanced by means of the
module lathing and ventilation orices at the eaves and
ridge. In addition, backside-ventilated crystalline modules
will offer a higher yield.
A structural stability of the roof and/or the roof substructure
with regard to wind and snow load, which allows the re-
sulting loads and forces to be absorbed and transfered by
the roof substructure – the rafters, lathing and connecting
elements – is a basic requirement for the installation of a
photovoltaic system .
2

Installation guide
2.4 Dimensionaldataanddimensions
Moduletype S-ClassIntegration
S-ClassIntegrationDeluxe
Module dimensions
W x H in mm 1682 x 864
Installation dimen-
sions
Wi x Hi in mm
1663 x 833
Horiz. installation
tolerance
∆Wi in mm
± 2.0
Vert. installation toler-
ance
∆Hi in mm
± 1.0
The calculation of the generator eld dimensions should
be used as a planning aid. The total PV system dimen-
sions serve to determine the footprint of the PV generator
in the roof. The calculated and the actual dimensions may
differ, as the installation tolerances were not taken into
consideration here.
Totalgeneratordimensionswithoutroongframe:
Width Wo in mm
= S x Wi
+ 19
where S = number of modules side by side
Height Ho in mm = R x Hi + 90
where R = number of modules on top of the other
Totalgeneratordimensionswith roongframe:
Width in mm Wm = Wo + 300
Height in mm Hm = Ho + 670
NumbernandlengthLofmodulelathing(38x58mm):
n = ( 2 x S ) + 1 [items]
L = Ho - 20 [mm]
Abbreviations:
W Module width
H Module height
Wi Module installation width
Hi Module installation height
∆Wi Horiz. installation tolerance
∆Hi Vert. installation tolerance
Wo Generator width without roong frame:
Ho Generator height without roong frame:
Wm Generator width with roong frame:
Hm Generator height with roong frame:
S Number of modules side by side
R Number of modules on top of the other
n Number of module laths
L Length of module laths
Alldimensionsareinmillimeter[mm]!
3

Installation guide
3 Scopeofsupply
3.1 Materialandtools
Scopeofsupply-material:
SOLRIF - xing bracket "Frame", "Field" and "Top"
4.5 x 35 Spax VA screws for xing bracket,
roong frame sets: Basic set, top, right and left, alumi-
num plastics sealing sheet
Materialtobeprovidedonsite:
Module / support lathing (roong laths / KVH 38 x 58
mm (quantities see dimensional information),
original roong laths* fastening screws for module /
support lathing according to DIN 1052 (woodworking
screws)
ventilation tiles for pantiled roofs (if required).
Listoftools:
Cordless screw driver and bits (PZ2)
Tape measure and chalkline
Laser angle and/or distance measuring instrument
* Additional roong laths (support for aluminum plastics
sealing sheet or top roong frame) must have the same
thickness as the existing roof lathing.
4

Installation guide
3.2 Listofmaterial
1 Aluminum plastics sealing sheet
2 Module laths 38 x 58
3 Fixing bracket "Frame"
4 Fixing bracket "Field"
5 Fixing bracket "Top"
6 Eaves ventilation comb
7 Roong frame right
8 Roong frame corner right
9 Roong frame top
10 Roong frame top "End piece"
11 Roong frame corner left
12 Roong frame left
13 Valley sealing strip
14 Metal retainers
1
2 2 2 2 2
3 3 34 4
5 5 5 5 5
6 6 6 6
7
7
891011
12
12
13
13
13
13
13
13
14
14
14
14
14
14
14
14
14
14
14 14 14 14 14 14 14 14
3 3 34 4
14 14
5

Installation guide
a - Fixing bracket "Field" (4)
b - Fixing bracket "Frame" (3)
c - Fixing bracket "Top" (5)
d - Spacer block
Screws = Spax VA 4.5 x 35
a - Fixing bracket left (12)
b - Fixing bracket right (7)
a - Fixing bracket corner left (11)
b - Fixing bracket corner right (8)
ab
c
d
ab
a
b
6

Installation guide
Roong frame top (9)
(left hand side feather edge to the top)
Roong frame top left (10)
(left hand side feather edge to the bottom)
a - Eaves ventilation comb (6)
b - Valley sealing strip (13)
c - Metal retainer (14)
with 4.5 x 25 Spax screw
a
b
c
7

Installation guide
4 Moduleconnection-circuitryproposals
8