CleanSpace CS302 Bedienungsanleitung

CS3021
CleanSpace HALO
USA - ENGLISH
CleanSpace Technology Pty Ltd
Unit 5, 39 Herbert Street,
St. Leonards, NSW, 2065,
Australia
USER
www.cleanspacetechnology.com INSTRUCTIONS

2
1. Contents
1.
Contents ............................................................................................................................................................... 2
2.
Foreword .............................................................................................................................................................. 3
3.
System Description .............................................................................................................................................. 3
4.
List of Warnings within these User Instructions ................................................................................................... 3
5.
NIOSH – Approval, Cautions and Limitations ..................................................................................................... 5
6.
S - Special or Critical User Instructions ............................................................................................................... 5
7.
Limitations of Use ................................................................................................................................................ 6
8.
Respirator Program Management ....................................................................................................................... 7
9.
System Components............................................................................................................................................ 8
10.
HALO BIO System ............................................................................................................................................... 9
11.
Controls and Indicators ...................................................................................................................................... 10
12.
Mask Fitting ........................................................................................................................................................ 11
13.
Using CleanSpace HALO with HALF MASKS ................................................................................................... 13
14.
Using CleanSpace HALO BIO with the Head Cover ......................................................................................... 21
15.
Using CleanSpace HALO with Full Face Masks ............................................................................................... 23
16.
Entering and Exiting the Contaminated Area .................................................................................................... 28
17.
Working in Noisy Environments ......................................................................................................................... 29
18.
Fitting & Changing the Filter .............................................................................................................................. 29
19.
Battery Information ............................................................................................................................................. 32
20.
Cleaning ............................................................................................................................................................. 34
21.
Periodic Maintenance & Checking ..................................................................................................................... 37
22.
Performing a Quantitative Fit Test ..................................................................................................................... 37
23.
Changing Half Mask Exhalation Valve Covers .................................................................................................. 39
24.
Specifications ..................................................................................................................................................... 40
25.
Product and Accessory information ................................................................................................................... 41
26.
Product Warranty ............................................................................................................................................... 42
Read these instructions in conjunction with the appropriate CleanSpace™ filters and accessories instructions.
Important: Before use, the wearer must read and understand these user instructions. Keep these user
instructions for reference.
WARNING
This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in
sickness. For proper use, consult an Occupational Health Specialist, these user instructions or contact CleanSpace
Technology Customer Support on [email protected] or the website:
www.cleanspacetechology.com/welcome/

3
2. Foreword
Read all instructions and warnings before using this device. Keep these user instructions for reference. If you have
questions regarding this system contact CleanSpace Customer Service on +612 8436 4000 or e-mail
3. System Description
CleanSpace HALO is a complete NIOSH-approved respiratory system. When used in accordance with its NIOSH
approval, the respirator helps to provide respiratory protection against particulates. HALO does not provide
protection against vapors or gasses and is not an intrinsically safe system. See the NIOSH Approval Section of
these user instructions for additional information on approvals.
The components of the CleanSpace HALO system are shown in Section 9. The blower draws ambient air through
the high efficiency filter and supplies filtered air to the wearer via the mask. HALO is a breath responsive respirator
which means that it blows harder during inhalation and more softly during exhalation. The device continuously
adjusts fan speed to maintain positive pressure in the mask. Should the filter become blocked, an audible alarm will
sound and the “Filter” light on the keypad will be illuminated. If the battery voltage falls below the minimum required
to sustain the designed flow rate, an audible alarm will sound.
The HALO BIO System includes a Head Cover which, in combination with the other HALO BIO components, helps
protect the head and neck from splash contamination. The HALO BIO Head Cover is used with the HALO Half
Masks, HALO BIO Exhalation Valve Cover and HALO BIO filter.
The HALO System includes two optional Exhalation Filters. The Steri-Plus Exhalation Filter Assembly (CS3038 and
CS3039) is used with the Standard Exhalation Valve Cover (PAF-1111) and no head cover. The Exhalation Filter –
HALO BIO (CS3027) is used with both the BIO Exhalation Valve Cover (CS3026) and the HALO BIO head cover.
WARNING
Properly selected, used and maintained respirators help to protect against certain airborne contaminants. It
is essential to follow all instructions and government regulations on the use of this product, including
wearing the complete respirator system during all times of exposure, in order for the product to help protect
the wearer. Misuse of respirators may result in overexposure to contaminants and lead to sickness. For
proper use, consult an Occupational Health Specialist, these user instructions or contact CleanSpace
Technology Customer Support on [email protected] or the website:
www.cleanspacetechology.com/welcome/
4. List of Warnings within these User Instructions
No Half Mask or Full Facepiece PAPR can fully protect you if you are not clean shaven. CleanSpace HALO is not
suitable for users with facial hair.
WARNING
This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in
sickness. For proper use, consult an Occupational Health Specialist, these user instructions or contact CleanSpace
Technology Customer Support on [email protected] or the website:
www.cleanspacetechology.com/welcome/
WARNING
Properly selected, used and maintained respirators help to protect against certain airborne contaminants. It is
essential to follow all instructions and government regulations on the use of this product, including wearing the
complete respirator system during all times of exposure, in order for the product to help protect the wearer. Misuse of
respirators may result in overexposure to contaminants and lead to sickness. For proper use, consult an Occupational
Health Specialist, these user instructions or contact CleanSpace Technology Customer Support on

4
If a satisfactory quantitative fit factor (above 1000) or passing qualitative test cannot be achieved with any of the
masks, CleanSpace HALO must not be used.
Do not use compressed air or a brush to clean the filter! HEPA filters are very easily damaged by the use of
compressed air or by brushing. Misuse of CleanSpace HALO by cleaning the filter may result in overexposure to
contaminants and lead to sickness.
If a satisfactory Seal Check cannot be achieved, do not enter the contaminated zone.
Be sure to remove the Seal Check Cap (Half Mask variants) before entering the contaminated area. The Cap blocks
the exhalation valve, making it more difficult for your exhaled air to be expelled from the mask. Failure to remove the
cap will lead to build-up of Carbon Dioxide in the mask, and may result in headache or dizziness. Never leave the
Cap in place for more than 2 minutes!
Do not leave the seal check cap in place for more than 2 minutes.
If you cannot adjust the mask to avoid your hairline, the mask is not suitable for you and must not be worn.
Do not remove the respirator until you have vacated the contaminated area unless you have pressing health reasons
to do so (for instance you are experiencing dizziness and believe removing the respirator while you leave the
contaminated area may help).
It is essential that the correct filter type is selected for the chosen application.
If the blocked filter alarm is triggered (2 beeps, repeated every second, red LED flashes), leave the contaminated
area immediately and replace the filter. Operating the respirator after the blocked filter alarm has sounded can cause
the flow to fall below the manufacturer’s minimum designed flow, which may result in overexposure to contaminants
and lead to sickness.
When fitting a new filter, the blocked filter alarm shall be tested before the respirator is put back into service. See the
heading “Testing the Blocked Filter Alarm” below.
CleanSpace HALO is not intrinsically safe. Do not use in flammable or explosive atmospheres. Doing so may result
in injury or death.
Always correctly use and maintain the internal lithium ion battery packs. Failure to do so may result in fire or
explosion or could adversely affect respirator performance and result in injury, sickness or death. Do not charge the
on-board battery with unapproved chargers, in enclosed cabinets without ventilation, near flammable liquids or
gasses, or near sources of high heat. Do not immerse the device in water. Do not use, charge or store the device
outside the recommended temperature limits.
If the battery alarm sounds (3 beeps, repeated every second), leave the contaminated area immediately and re-
charge the battery. Operating the respirator after the low battery alarm has sounded can cause the flow to fall below
the manufacturer’s minimum designed flow, which may result in overexposure to contaminants and lead to sickness.
In the extremely rare circumstance that the battery is damaged and electrolyte comes in contact with eyes, flush with
water immediately and seek urgent medical attention.
The Steri-Plus and HALO BIO Exhalation Filters (CS3039 and CS3027 respectively) are electrostatic filters and their
performance will be degraded by exposure to certain organic solvents including isopropanol (IPA), xylene and
toluene. Always remove the Exhalation Filter before cleaning the mask. If there is a possibility that the Exhalation
Filter has become contaminated with any solvent, replace it.
Never dry the mask or exhalation valve with a cloth that may leave behind lint. Lint contamination of the exhalation
valve may cause it to leak, resulting in overexposure to contaminants and lead to sickness.

5
Using a full face mask with the rain cover raised can cause the exhalation valve to vibrate, which you may notice as a
buzzing noise. Lower the rain cover for correct operation.
The blower contains a battery, sensitive electronics and a motor. Never immerse it in water or use anything wetter
than a damp cloth to clean it.
You must recalibrate the internal pressure sensor any time that your CleanSpace HALO is exposed to changes in
temperature of more than 20°C. It is best practice to also re-calibrate if the unit has been in storage, particularly if the
storage temperature is not known.
To check that the test port plug is fitted correctly (after using the on-board fit test ports), a negative pressure Seal
Check shall be performed – see page 25.
5. NIOSH – Approval, Cautions and Limitations
NIOSH APPROVAL
CleanSpace HALO is a NIOSH-approved respirator system. Refer to these User Instructions and to the NIOSH
approval label provided with each CleanSpace HALO for a listing of components that can be used to form a NIOSH-
approved respirator.
NIOSH CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
F - Do not use powered air-purifying respirators if airflow is less than four cfm (115 lpm) for tight fitting facepieces or
six cfm (170 lpm) for hoods and/or helmets.
I – Contains electrical parts that may cause an ignition in flammable or explosive atmospheres.
J - Failure to properly use and maintain this product could result in injury or death.
L - Follow the manufacturer's User's Instructions for changing cartridges, canister and/or filters.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and
other applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified
by the manufacturer.
O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these
respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
S - Special or critical User's Instructions and/or specific use limitations apply. Refer to User's Instructions before
donning.
6. S - Special or Critical User Instructions
This respirator contains a system for synchronizing with your breathing and regulating mask pressure. This system
requires re-calibration whenever it experiences a change in temperature of more than 36°F (20°C). It is best
practice to also re-calibrate if the unit has been in storage, particularly if the storage temperature is not
known.
For the most accurate battery charge indication, the respirator must be plugged into its charger. To be sure it is fully
charged, plug in the charger and wait for all 3 LEDs to light solidly without flashing. If the 3rd LED is flashing
rapidly, the battery is 95% charged.
The CS3024 Head Cover shall only be used in combination with a HALO Half Mask configured with the HALO BIO
Exhalation Valve Cover, and with the CS3025 Filter HE – HALO BIO. No other combination of mask and filter is
approved for use with the HALO BIO Head Cover. Note: The HALO BIO is a tight-fitting half mask PAPR. The head
cover does not provide or contribute to the system’s respiratory protection.

6
The HALO half masks are approved and may be used without the Head Cover with either the HE Filter HALO BIO
(CS3025) or the HALO Standard HE Filter (CS3022). When configured with either of these filters, the HALO half
masks are approved and may be used with either the Standard Exhalation Valve Cover or the BIO Exhalation Valve
Cover.
The CS3038 Steri-Plus Exhalation Filter Case and the CS3039 Steri-Plus Exhalation Filter shall only be used in
combination with a HALO Half Mask fitted with the PAF-1111 Standard Exhalation Valve Cover. The Steri-Plus
Exhalation Filter shall NOT be used with the Head Cover. Note: The HALO Exhalation Filter does not provide or
contribute to the system’s respiratory protection. An HE Filter (CS3022 or CS3025) must be used.
The CS3027 HALO BIO Exhalation Filter shall only be used in combination with a HALO Half Mask fitted with the
CS3026 HALO BIO Exhalation Valve Cover. The HALO BIO Exhalation Filter can be used with or without the Head
Cover. Note: The HALO BIO Exhalation Filter does not provide or contribute to the system’s respiratory protection.
An HE Filter (CS3022 or CS3025) must be used.
Ensure that either the Standard Exhalation Valve Cover or BIO Exhalation Valve Cover (as applicable for the
intended configuration) is installed prior to use.
7. Limitations of Use
Use this Respirator strictly in accordance with all instructions in these user instructions and NIOSH Approval Labels.
Never modify or alter this product.
Do not remove the Respirator until you have left the contaminated area,
unless you have pressing health reasons to do so (for instance you are experiencing dizziness and
believe removing the respirator while you leave the contaminated area may help).
Only suitable for use by clean-shaven personnel. Facial hair under the seal reduces protection and is not
permitted.
Note: Half Mask variants of CleanSpace do not protect your eyes. In conditions that may damage or
irritate eyes, use protective eyewear or a full-face variant of CleanSpace.
Only use your respirator with the parts and accessories listed on the Approval Label.
Do not use the respirator unless it is powered and running normally.
Do not use the respirator while it is being charged via the AC adaptor.
Do not use in airborne contaminant concentrations above those specified in your national regulations.
Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations
of contaminants are unknown or immediately dangerous to life or health (IDLH).
Do not use in oxygen deficient or oxygen enriched atmospheres. Do not use in flammable or explosive
environments.
Only for use by trained personnel.
Filters need to be changed regularly. The frequency of change depends on use and the concentration of
contaminants in the atmosphere.
Do not use for escape purposes. National regulations may impose specific limitations on the use of filters
depending on the filter class and the facemask used.
LEAVE THE CONTAMINATED AREA IMMEDIATELY IF:
respirator warning lights and/or sounds activate for low battery or blocked filter
any part of the respirator is damaged
air flow into the mask decreases or stops
breathing becomes difficult or increased resistance occurs
you feel dizzy or your airway is irritated
you can taste or smell contaminants.
Your respirator is suitable for use in the following atmospheric conditions:
Temperature: 14°F to 113°F (-10°C to 45°C).
Relative humidity: 0 to 90% non-condensing.
The respirator will stop functioning if its internal temperature rises above 140°F (60°C) or falls below 14°F (-10°C).
If the respirator has been used in an area that has caused it to become contaminated with a substance requiring
special decontamination procedures it should be placed in a suitable container and sealed until it can be
decontaminated.

7
Do not disassemble the respirator case. There are no user serviceable parts inside.
Failure to follow all instructions on the use of this product, and/or failure to use the respirator during times of
exposure, may lead to adverse effects on the wearer’s health and may render the warranty void.
WARNING
This product is part of a system that helps protect against certain airborne contaminants. Misuse may
result in sickness. For proper use, consult an Occupational Health Specialist, these user instructions or
contact CleanSpace Technology Customer Support on [email protected] or the
website: www.cleanspacetechology.com/welcome/
8. Respirator Program Management
Occupational use of respirators must be in compliance with applicable health and safety standards. By United States
regulation employers must establish a written respiratory protection program meeting the requirements of the
Occupational Safety and Health Administration (OSHA) Respiratory Protection standard 29 CFR 1910.134, Standard
Practice for Respiratory Protection ASTM F3387 and any applicable OSHA substance specific standards. For
additional information on this standard contact OSHA at www.OSHA.gov. In Canada, CSA standard Z94.4
requirements and/or the requirements of the applicable jurisdiction must be met. Contact an industrial hygienist or
CleanSpace Technology Technical Service with questions concerning the applicability of the respirator to your job
requirements.

8
Figure 1 – System Components
9. System Components

9
Figure 2 – Parts of the Respirator
PARTS OF THE RESPIRATOR
Throughout this manual reference is made to various commonly-used components and features of the respirator.
Familiarize yourself with these parts before reading the rest of the manual. See Figure 2.
10. HALO BIO System
The HALO BIO Respiratory Protection System is a user-configurable respiratory protection system designed to
provide for multiple configurations to best suit the user’s environment of use and application. These instructions and
the NIOSH Approval Label detail the variable configurations available and approved.
A fully configured HALO BIO system incorporates:
CS3024 Head Cover – HALO BIO
Half Mask – HALO (CS3003 small, CS3004 medium or CS3005 large)
CS3025 Filter HE – HALO BIO
CS3026 BIO Exhalation Valve Cover - HALO BIO
(optionally) CS3027 Exhalation Filter – HALO BIO
Notes:
The HALO BIO is a tight-fitting half mask PAPR. The head cover does not provide or contribute to the
system’s respiratory protection.
The CS3024 Head Cover shall only be used in combination with a HALO Half Mask (CS3003 Small,
CS3004 Medium and CS3005 Large) which has been configured to adapt to the Head Cover by fitting

10
CS3026 BIO Exhalation Valve Cover – HALO BIO; and with CS3025 Filter HE – HALO BIO which are
specifically designed to interface to the Head Cover. No other combination of mask and filter is approved
for use with the HALO BIO Head Cover.
The HALO Half Masks when configured with the CS3026 BIO Exhalation Valve Cover – HALO BIO are
approved and may be used without the Head Cover, with either the HE Filter HALO BIO (CS03025) or
the HALO Standard HE Filter (CS3022).
The optional Exhalation Filter (CS3027) may be used with or without the HALO BIO Head Cover.
The BIO Exhalation Valve Cover can be cleaned or disposed of depending on the user’s environment
and/or application. For instructions on removing it see Section 20.
11. Controls and Indicators
POWER BUTTON
This button is used to switch between the three (3) operating Modes: “On”, “Standby” and “Off”
Mode.
i)
Standby Mode is when the green battery indicator lights are on, the motor is not running and
there is no airflow to the mask. The respirator will automatically switch to Standby Mode within ten
(10) seconds of the user taking it off. If the respirator is in Off Mode it will switch to Standby Mode when the Power
button is pressed.
ii)
On Mode is when the respirator is being worn, the motor is running and there is air flow to the mask. The motor
will start (called On Mode) when the respirator detects a change in pressure in the mask triggered by your breathing.
In On Mode you should hear the motor running and feel the airflow on your face. You can also switch to On Mode
(start the motor) from Standby Mode by pressing the Power button once.
iii)
Off Mode is when the green battery indicator lights are off and the motor is not running and there is no air flow to
the mask. The respirator automatically switches into Off Mode three (3) minutes after it has been removed from the
user’s face and the sensors detect that there is no breathing.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere CleanSpace Atemwegsprodukt Handbücher

CleanSpace
CleanSpace HALO Bedienungsanleitung

CleanSpace
CleanSpace ULTRA Montageanleitung

CleanSpace
CleanSpace PRO Bedienungsanleitung

CleanSpace
CleanSpace ULTRA Bedienungsanleitung

CleanSpace
CleanSpace PAF-0060 Bedienungsanleitung

CleanSpace
CleanSpace EX Bedienungsanleitung

CleanSpace
CleanSpace HALO CS3021 with BIO-HOOD Bedienungsanleitung

CleanSpace
CleanSpace CleanSpace2 Bedienungsanleitung

CleanSpace
CleanSpace HALO Bedienungsanleitung

CleanSpace
CleanSpace EX Bedienungsanleitung