CLF Dynamic white par Bedienungsanleitung

manual
V2.0 AUGUST 2017WWW.CLF-LIGHTING.COM
dynamic white par

WWW.CLF-LIGHTING.COM
Dimensions 1
Safety information 2
Fixture overview 4
Introduction 5
AC power 5
Power voltage 5
Power cables 6
Relaying power to other devices 6
Data link 6
Tips for reliable data transmission 6
Physical installation 7
Setup 8
Control panel and menu navigation 8
DMX address setting 8
Control mode 8
Menu navigation 9
DMX protocols 10
Specications 12
Blow-out diagram 13
table of CONTENTS

WWW.CLF-LIGHTING.COM
1.0
Dimensions
All dimensions are in millimeters
387
125
255
495
336
233
381
111
290
340
G Clamp with
Quicklock #875760
(Optional)
260
326
233
G Clamp with
Quicklock #875760
(Optional)
206
303
257
278
207
G Clamp with
Quicklock #875760
(Optional)
312
312
250.3
199
108
250
152
200
G Clamp with
Quicklock #875760
(Optional)
238 148
190
G Clamp with
Quicklock #875760
(Optional)
255
195
280
G Clamp with
Quicklock #875760
(Optional)
Camlock system
105
Bracket adjustment knob
60º
480
140
G Clamp with
Quicklock #875760
(Optional)
G Clamp with
Quicklock #875760
(Optional)
483
125
153
150
205
255
177
300
G Clamp with
Quicklock #875760
(Optional)
158
178
106
259
G Clamp with
Quicklock #875760
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
291
387
125
255
495
336
233
381
111
290
340
G Clamp with
Quicklock #875760
(Optional)
260
326
233
G Clamp with
Quicklock #875760
(Optional)
206
303
257
278
207
G Clamp with
Quicklock #875760
(Optional)
312
312
250.3
199
108
250
152
200
G Clamp with
Quicklock #875760
(Optional)
238 148
190
G Clamp with
Quicklock #875760
(Optional)
255
195
280
G Clamp with
Quicklock #875760
(Optional)
Camlock system
105
Bracket adjustment knob
60º
480
140
G Clamp with
Quicklock #875760
(Optional)
G Clamp with
Quicklock #875760
(Optional)
483
125
153
150
205
255
177
300
G Clamp with
Quicklock #875760
(Optional)
158
178
106
259
G Clamp with
Quicklock #875760
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
291
HANGING BRACKET / FLOOR STAND
BRACKET ADJUSTMENT KNOB

WWW.CLF-LIGHTING.COM
Safety Information
The following symbols are used to identify important safety information on the product and in this manual:
WARNING!
Read the safety precautions in this section before
installing, powering, operating or servicing this
product
DANGER!
Safety hazard.
Risk of severe
injury or death.
DANGER!
Hazardous
voltage. Risk of
lethal or severe
electric shock.
WARNING!
Fire hazard.
WARNING!
LED light
emission. Risk of
eye injury.
WARNING!
Burn hazard. Hot
surface. Do not
touch.
WARNING!
Wear protective
eyewear.
WARNING!
Refer to user
manual.
Warning! Risk Group 3 (high risk) LED product according to EN 62471. Do not look into the beam at a distance
of less than 8.3 meters from the front surface of the product. Do not view the light output with optical
instruments or any device that may concentrate the beam.
This product is for professional use only. It is not for household use.
This product presents risks of severe injury or death due to fire and burn hazards, electric shock and falls.
Read this manual before installing, powering or servicing the fixture, follow the safety precautions listed below and
observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture
safely, please contact your supplier.
PROTECTION FROM ELECTRIC SHOCK
Disconnect the fixture from AC power before removing or installing any cover or part and when not in use.
Always ground (earth) the fixture electrically.
Use only a source of AC power that complies with local building and electrical codes and has both overload and
ground-fault (earth-fault) protection.
Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for
the current requirements of all connected devices.
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) minimum
conductor size and an outer cable diameter of 5 - 15 mm . Cables must be hard usage type (SJT or equivalent) and
heat-resistant to 90° C minimum.
Use only powerCON cable connectors to connect to power input sockets. Use only powerCON cable connectors to
connect to power through put sockets.
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component is
damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs have been
completed.
2.0

WWW.CLF-LIGHTING.COM
Do not expose the xture to rain or moisture
• Refer any service operation not described in this manual to a qualied technician.
• Socket outlets used to supply xture xtures with power or external power switches must be located near the xtures
and easily accessible so that the xtures can easily be disconnected from power.
PROTECTION FROM BURNS AND FIRE
• Do not operate the xture if the ambient temperature (Ta) exceeds 40° C .
• The exterior of the xture becomes hot during use. Avoid contact by persons and materials.
Allow the xture to cool for at least 5 minutes before handling.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 100 mm away from the xture.
• Keep ammable materials well away from the xture.
• Ensure that there is free and unobstructed airow around the xture.
• Do not illuminate surfaces within 200 mm of the xture.
• Do not attempt to bypass thermostatic switches or fuses.
• If you relay power from one xture to another using power throughput sockets, do not connect more than ten xture
xtures in total to each other in an interconnected chain.
• Connect only other xture xtures to xture power throughput sockets.
• Do not connect any other type of device to these sockets.
• Do not stick lters, masks or other materials onto any optical component.
• Do not modify the xture in any way not described in this manual.
PROTECTION FROM INJURY
• Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the xture without
protective eyewear such as shade 4-5 welding goggles. At less than this distance, the LED emission can cause eye
injury or irritation. At distances of 3 meters and above, light output is harmless to the naked eye provided that the
eye’s natural aversion response is not overcome.
• Do not look at LEDs with magniers, telescopes, binoculars or similar optical instruments that may concentrate the
light output.
• Ensure that persons are not looking at the LEDs from within 8.3 meters when the product lights up suddenly.
This can happen when power is applied, when the product receives a DMX signal, or when SERVICE menu items
are selected.
• Fasten the xture securely to a xed surface or structure when in use. The xture is not portable when installed.
• Ensure that any supporting structure and/or hardware used can hold at least 10 times the weight of all the devices
they support.
• Allow enough clearance around the head to ensure that it cannot collide with an object or another xture when it moves.
• Check that all external covers and rigging hardware are securely fastened.
• Block access below the work area and work from a stable platform whenever installing, servicing or moving the xture.
• Do not operate the xture with missing or damaged covers, shields or any optical component.
3.0

WWW.CLF-LIGHTING.COM
xture overview
max 10.7A
4.0
387
125
255
495
336
233
381
111
290
340
G Clamp with
Quicklock #875760
(Optional)
260
326
233
G Clamp with
Quicklock #875760
(Optional)
206
303
257
278
207
G Clamp with
Quicklock #875760
(Optional)
312
312
250.3
199
108
250
152
200
G Clamp with
Quicklock #875760
(Optional)
238 148
190
G Clamp with
Quicklock #875760
(Optional)
255
195
280
G Clamp with
Quicklock #875760
(Optional)
Camlock system
105
Bracket adjustment knob
60º
480
140
G Clamp with
Quicklock #875760
(Optional)
G Clamp with
Quicklock #875760
(Optional)
483
125
153
150
205
255
177
300
G Clamp with
Quicklock #875760
(Optional)
158
178
106
259
G Clamp with
Quicklock #875760
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
Omega Bracket
with Quicklock #520114
(Optional)
291
SAFETY
POWER OUT
DMX OUT
CONTROL BOARD
DMX IN
POWER IN

WWW.CLF-LIGHTING.COM
introduction
ac power
Compact cold white & warm white LED xture:
• 25° beam angle
• Extensive white color temperature control (2.800K – 6.500K, CRI>90)
• Solid housing
• Double bracket for oor and truss mounting
• ‘Flicker free’ operation
• Powercon in and out
Using for the rst time
Warning! Read “Safety Information” on page 2 before installing, powering, operating or servicing the xture.
Before applying power to the xture:
• Check that the local AC mains power source is within the xture’s power voltage and frequency ranges.
• See “Power cables and power plug” on page 6. Install a powerCON power input connector on a suitable power
cable. If drawing power from a mains power outlet, install a suitable power plug on the power cable.
Warning! Read “Safety Information” starting on page 2 before connecting the xtures to AC mains power.
Warning! For protection from electric shock, the xture must be grounded (earthed). The power distribution
circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault) protection.
Warning! Socket outlets or external power switches used to supply the xture with power must be located
near the xture and easily accessible so that the xtures can easily be disconnected from power.
Important! Do not insert or remove live powerCON connectors to apply or cut power, as this may cause
arcing at the terminals that will damage the connectors.
Important! Do not use an external dimming system to supply power to the xture, as this may cause damage
to the xture that is not covered by the product warranty.
The xture can be hard-wired to a electrical installation if you want to install it permanently, or a power plug that is
suitable for the local power outlets can be installed on the power cable.
power voltage
Warning! Check that the voltage range specied on the xtures serial number label matches the local AC
mains power voltage before applying power to the xture.
The xtures accepts AC mains power at 100-240 V nominal, 50/60 Hz. Do not apply AC mains power to the xture at
any other voltage than specied on the xture’s serial number label.
5.0

WWW.CLF-LIGHTING.COM
power cables
Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) minimum
conductor size and an outer cable diameter of 5 - 15 mm. Cables must be hard usage type (SJT or equivalent) and
heat resistant to 90°C minimum. In the EU the cable must be HAR approved or equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated 20 A minimum.
Follow the plug manufacturer’s instructions. Table 1 shows standard wire color-coding schemes and some possible
pin identication schemes; if pins are not clearly identied, or if you have any doubts.
Relaying power to other devices
Warning! Do not connect more than 8 xtures in total to AC mains power in one interconnected chain.
Power can be relayed to another device via the light-grey PowerCon throughput socket.
If you daisy chain the xtures in a chain so that they all draw AC mains power via the rst xture, certain points must be
respected:
• A heavy duty, three-conductor, 16 AWG or 1.5 mm2 cable with SJT or equivalent cable jacket must be used to
connect the rst xture to AC mains power.
• PowerCON connectors must be used to draw AC mains power from the xtures power output sockets. Blue power-
CON connectors must be used to supply power through the xture’s power input sockets.
A DMX 512 data link is required in order to control a xture via DMX. The xture has 3-pin XLR connectors for DMX
data input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+).
tips for reliable data transmission
To connect the xture to data:
1. Connect the DMX data output from the controller to the closest xture’s male 3-pin XLR DMX input connector.
2. Connect the DMX output of the xture closest to the controller to the DMX input of the next xture and continue
connecting xtures output to input.
Wire Color (EU models) Wire Color (USmodels) Conductor Symbol Screw (US)
Brown Black Live L Yellow or Brass
Blue White Neutral N Silver
Yellow/Green Green Ground (earth) or Green
Table 1: Wire color-coding and power connections
6.0
DATA LINK

WWW.CLF-LIGHTING.COM
Warning! The xture must be either fastened to a at surface such as a stage or wall, or clamped to a truss or
similar structure in any orientation using a rigging clamp.
Warning! If the xture can cause injury or damage it if falls, attach an approved safety cable to one of the
safety cable attachment points on the base (see “Fixture overview” on page 4).
Check that all surfaces to be illuminated are minimum 200 mm. from the xture, that combustible materials
(wood, fabric, paper, etc.) are minimum 100 mm. from the head, that there is free airow around the xture
and that there are no ammable materials nearby. Make sure that it is impossible for the moving head to
collide with another xture or other object.
Fastening the xture to a at surface
The xture can be fastened to a xed at surface that is oriented at any angle. Check that the surface can support at
least 10 times the weight of all xtures and equipment to be installed on it.
Warning! The supporting surface must be hard. Fasten the xture securely. Do not stand it on a surface or leave
it where it can be moved or can fall over. Attach a securely anchored safety cable to the safety cable attachment
point (see “Fixture overview” on page 4) if the xture is to be installed in any location where it may fall and
cause injury or damage if the primary attachment fails.
1. Block access under the work area. Working from a stable platform, hang the xture on the truss with the arrow on
the base towards the area to be illuminated. Tighten the rigging clamp.
2. Secure the xture against clamp failure with a secondary attachment such as an approved safety cable that is rated
for the weight of the xture using one of the attachment points at the edges of the base (see “Fixture overview” on page 4).
Do not use any other part of the xture as a safety cable attachment point.
7.0
Physical installation

WWW.CLF-LIGHTING.COM
Warning! Read “Safety Information” on page 2 before installing, powering, operating or servicing the xture.
Control panel and menu navigation
The onboard control panel and display are used to set the xture’s DMX address, congure individual xture settings
(personality), read out data and execute service utilities. See “Menu Navigation” on page 9 for a complete list of menus
and commands.
Using the control buttons
• To enter the menu select [MODE].
• Press [UP] and [DOWN] to scroll within a menu or adjust values.
• To enter a menu, select a function or apply a selection, press [ENTER].
• To escape a function or move back one level in the menu structure, press [MODE].
DMX address setting
The DMX address, also known as the start channel, is the rst channel used to receive instructions from the controller.
For independent control, each xture must be assigned its own control channels.
The DMX address is congured using the DMX address [DMX] menu in the control panel. For setting the DMX address
press [ENTER] before you can change the adddres.
• If a DMX signal is presented to the xture, a red dot is shown on the menu screen.
Control mode
DMX control mode is selected in the control mode [PERS] menu. The xture has three DMX control modes:
2ch 3ch 7ch
Cool white & warm white
CCT
Dimming
Strobe
ID
Dimmer Speed
8.0
SETUP
Inhaltsverzeichnis
Andere CLF DJ-Equipment Handbücher
Beliebte DJ-Equipment Handbücher anderer Marken

thomann
thomann Stairville DJ Lase 40-G MK-III Bedienungsanleitung

Eagletone
Eagletone 6 Eyes Flower Bedienungsanleitung

EuroLite
EuroLite FLD-1508 Bedienungsanleitung

Technical Pro
Technical Pro LG8xSEA Bedienungsanleitung

JB Systems
JB Systems Lounge Laser DMX Bedienungsanleitung

Lightmaxx
Lightmaxx Vega Halo 90 Bedienungsanleitung

Elation
Elation FUZE WASH Z350 Bedienungsanleitung

Maverick
Maverick MK3 WASH Bedienungsanleitung

Infinity
Infinity TF-260C7 Fresnel Bedienungsanleitung

Chauvet
Chauvet EVE E-50Z Bedienungsanleitung

Eliminator Lighting
Eliminator Lighting E 138 Bedienungsanleitung

EuroLite
EuroLite Mini Multicolor LED Flashing Light SC Bedienungsanleitung