CNDINGTEK DO200 Merkblatt

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 1
DO200 Parking Occupation Sensor
Configuration Manual
-----NB-IoT Version
V2.1
Date:2019-09-10

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 2
Changed
V2.1 Change the picture of hardware and add interface of capacity;
V2.0 Change the hatdware version;
V1.0 Initial version;

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 3
Index
1 Overview................................................................................................................................................4
2 Device Function DO200_NB-IoT Parking Occupation Sensor's........................................................4
3 How to install NB-IoT SIM card?......................................................................................................... 4
4 How to restart sensor through magnet?.............................................................................................5
5 Device interface definition................................................................................................................... 5
6 Modify device parameters(Upload time,APN...).................................................................................6
6.1 Required tools............................................................................................................................ 6
6.2 Connect TTL to sensor..............................................................................................................7
6.3 Configure device parameters (upload time, APN etc.)........................................................... 8
7 Protocol and API Interface.................................................................................................................13
8 FAQ....................................................................................................................................................... 13

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 4
1 Overview
These documents are helpful to understand the DO200 Parking Occupation Sensor’s
following:
▪Function of Device
▪How to install SIM card?
▪Protocol and API
▪Hardware Interface(debug/configure interface and battery interface )
▪Modify equipment parameters ( upload interval and APN,IP ....)
▪FAQ
2 Device Function DO200_NB-IoT Parking Occupation
Sensor's
Function:The device can detect if the parking space is occupied. When the vehicle is
detected to enter or leave, the sensor will be triggered to report the data.
When the device is restarted and the device is restarted, the sensor will learn the
surrounding environment, so it is considered to be a car-free state at this time.
3 How to install NB-IoT SIM card?
NB-IoT Sim card:MICRO card,;the frequency band of the SIM card used needs to be
the same as the device frequency band.
Insert NB card: sensor use self-elastic card slot, please find the card slot and insert
the NB card(If you want to change or remove the card, please press the card and it
will pop up automatically.).
Please pay attention to the installation direction of the card, as shown below:

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 5
4 How to restart sensor through magnet?
Magnet:
Move the magnet around the probe one turn and remove the magnet. This process
restarts the device. If the device is successfully rebooted, the device will report a
data that is displayed as being moved and the current full/empty state.
5 Device interface definition
The detailed of power interface , device parameter configuration interface are given

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 6
here, as shown in figure 5.1.
Figure5.1
Figure5.2
6 Modify device parameters(Upload time,APN...)
This section describes how to modify the parameters of the device through the serial
port, such as upload time interval, APN,and so on.
6.1 Required tools
●TTL and its cable; TTL and cable for the goods accessories Please check these
two items when you receive package from company as shown in Figure6.1 and
Figure6.2.
●Serial software
TX
RX
GND
This power socket is
used to connect the
battery.
This interface is used
to configure device
parameters (data
upload interval, APN,
IP, etc.), device
upgrade, or device
debugging.
Connect the
capacitor(bl
ue,2pin)
here
Capacity
Battery

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 7
●Equipment
Note: the TTL we sent may be different from the appearance with the picture.
Figure 6.1 Figure6.2
Serial software:,of course if you have other COM software, you can also
use yourself.
6.2 Connect TTL to sensor
Steps:
1Connect TTL to sensor, as shown in figure6.4, e.g: figure6.5. Device serial port
definition: GND, TX and RX positions have been marked on the diagram. as shown in
Figure6.3.
TX
RX
GND

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 8
Figure6.3
TTL and device connection as shown in figure 6.4:
Figure6.4
Figure 6.5
6.3 Configure device parameters (upload time, APN etc.)
After completing the two steps 6.1 and 6.2, you can refer to this step to configure
the corresponding parameters through the serial port software.
1 serial port software parameter setting
Open the serial port software. The default serial port information is shown in Figure
6.6.
The parameters required for the DO200 serial port are shown in Figure 6.7;
Port number ( you can select port Number from device manager of your system)
Set the baud rate: 115200
Parity bit: NONE
TTL Tools
Sensor
TX
RX
GND
TX
RX
GND

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 9
Data bits: 8
Stop bit: 1
Figure6.6 Interface by default
Figure6.7 parameters setting

DO200 Parking Occupation Sensor_NB-IoT_V2.1
Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863,64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 10
2 Connect the device's power(battery)
Connect the capacity and battery to the connector location on the motherboard as
shown in Figure 6.8:
Figure6.8 Connect the battery
3 Send command
When the battery is connected, you can see some information output from the serial
port. At this point, the device starts working and can send commands. At this time,
the corresponding parameters can be configured to configure the required
parameters.
Note: when the serial show “sleep”,mean that the sensor have come into sleep mode
Sending instructions at this time is invalid.so you need to restart the sensor by
magnet.
For example 1: change upload time to 10 hours
The command is: 8888010A, as shown in figure6.9,
Andere Handbücher für DO200
2
Inhaltsverzeichnis
Andere CNDINGTEK Automobilelektronik Handbücher