Cool-A-Zone CoolBox Bedienungsanleitung

USER MANUAL
9052 Long Point • Houston, TX 77055
888.827.1675 • [email protected]
Facebook.com/CoolAZone • Twitter.com/CoolAZone
OUR COMPLETE LINE
EVAPORATIVE AIR COOLER
CZ-C100 Manual-rev.indd 1 8/1/12 10:48 AM

TABLE OF CONTENT
Table of Contents & How It Works...........................................1
Installation & Set-Up..............................................................2
Dust Screen & Side Panel........................................................3
Managing the Water Reservoir...............................................3
LCD Button Panel & Remote Control.......................................4
Basic Operation & Powering On..............................................5
CoolBox Controls ....................................................................6-7
Using theTimer Feature .........................................................8
Routine Maintenance.............................................................8
Basic Troubleshooting ............................................................9
Circuit board & Specications.................................................10
Contact Information...............................................................11
INSTALLATION AND INITIAL SET-UP
If the fan must be placed close to a wall or other obstacle, try to keep a distance of 2 to 3 feet
between the wall or obstacle and the face of the cooling pads.
When placing the fan, take the following into consideration:
A. Uninterrupted fresh air should be made available to the cooling pad side of the unit for
best results.
B. Avoid blocking the air output (front) side of the fan. Cool air released from the unit should
be able to freely circulate.
C. In order to prevent air from being re-circulated, ensure that the area to be cooled is
properly ventilated.
D. If your CoolBox did not come with the truckles (the wheel assembly legs) attached, please
see the below instructions on how to do so.
EVAPORATIVE AIR COOLER
CoolAZone.com
HOW COOL-A-ZONE WORKS
Water Distrubutor
Cool-A-Zone’s water reservoirs
hold up to 37 gallons. With
add-on reservoir capacity,
you can run your Cool-A-Zone
longer without refilling!
Cool-A-Zone’s
Evaporative Pad
Cool-A-Zone’s beltless,
direct-powered stainless
steel fan.
HOT AIR
COMES IN
COOL AIR
COMES
OUT
TRUCKLE UNATTACHED TRUCKLE ATTACHED
Truckle Attaching Points Finished Assembly
1. Take two sets the Truckles (above left, shown unattached).
2. Use the enclosed ST5×25 bolts to stable the assembled frame to the bottom of the water
tank through the attaching points as shown on the left which will line up with
corresponding points on the unit.
3. When completed, the nished truckle-body assembly area should look as shown above on
the right.
1 2
CZ-C100 Manual-rev.indd 2 8/1/12 10:48 AM

DUST SCREEN & SIDE PANEL
ACCESSING THE DUST SCREEN AND SIDE PANEL
If you need to access the Dust Screen and Side Panel on your CoolBox, follow the instructions
below.
Using a Phillips (“crosshair”) Screwdriver, as follows:
A. Take the eight screws o the dust screen housing as shown in the picture below (left).
B. Once the eight screws are removed, gently remove the housing and side panel to access
the two (2) dust screens.
C. Reverse the steps above and securely replace the housing to again use your Cool-A-Zone
CoolBox.
LCD BUTTON PANEL
THE LCD BUTTON PANEL
The Cool-A-Zone CoolBox has a user-friendly and easy-to-use LCD indication panel with
one-touch button features for activating, timing, setting, and full control of your CoolBox. The
diagram below outlines what the various buttons and indicators mean. Note that the central
area (in white below) is an indication panel, whereas the grey area denotes the buttons.
Pages 7 & 8 will go into detail on the various Buttons & Indicators.
3 4
EVAPORATIVE AIR COOLER
...then gently
remove the panel
Remove all
attaching screws...
MANAGING THE WATER RESERVOIR
Ausion Panel Drain Valve
To fill your Cool-A-Zone CoolBox, simply open the Ausion
Panel (above) and fill with water or attach a garden hose to
the hose attachment and turn on faucet–the internal oat
valve will regulate water ow.
Draining is just as easy: turn the unit o, unplug,
then turn the drain valve knob counter clockwise to
empty the reservoir.
REMOTE CONTROL
Not sure if you hit the right button?
Always check the CoolBox LCD indicator
panel status lights to see.
If the remote appears to not work,
check to see if you have a clear line of
sight to the CoolBox.
POWER:
Turn the device on/o
AIR SPEED CONTROL:
Increase or decrease air flow
NO FUNCTION ON THIS MODEL
TIMER BUTTON:
Activates Timer feature
COOL:
Start or stop the Cool function
SWING:
Turns Swing function on/o
NO FUNCTION ON THIS MODEL
Hose Attachment
Show
Ventilation Show
Airow
Show
Temperature
Show
swing
Show
timer
Water
shortage Show anion Show
cooling
SPEED
COOL
ON/OFF
SWING
Remote
receiver
TIMER ANION
CZ-C100 Manual-rev.indd 3 8/1/12 10:48 AM

BASIC OPERATION
INITIAL OPERATION
After ensuring the unit has adequate water for operation and that your CoolBox has been
plugged in, turn the Cool-A-Zone CoolBox on by pressing the power button either on the LCD
Panel face or as shown on the remote control on Page 5 of this manual.
COOLBOX CONTROLS
USING YOUR COOLBOX
1. Power Button: turns the unit ON or OFF.
2. Speed Button: this controls the airow. On rst operation, the CoolBox will be at
SPEED 2 (there are three Speeds, 1 being the lowest and 3 being the highest).
Pressing again will take you up to SPEED 3, then pressing it again will bring you down to
SPEED 1. The rate of speed will be re ected on the Airow Indicator. If using the remote
control, the Speed Button works in the same way.
3. The Cool Button: switches the Cool-A-Zone CoolBox from COOL to VENTILATION mode.
One press will switch between the two functions.The COOL mode will activate the
pump and water will be used to evaporatively cool, whereas the VENTILATION mode will
simply circulate the air and deactivate the pump. If using the remote control, pressing the
COOL button will turn the pump on or o.
4. The Cool Indicator: When lit, this indicates that the Cool-A-Zone CoolBox is in COOL
mode. When unlit, this indicates the Cool-A-Zone CoolBox is in VENTILATION mode.
5. The Airow Indicator: The lowest bar indicates SPEED 1, the middle bar indicates
SPEED 2, and the highest bar indicates SPEED 3.
6. The Anion Indicator: When lit, the Anion function is ON, when unlit, the Anion function
is OFF.
5 6
EVAPORATIVE AIR COOLER
Before powering up, check the following:
- Is the unit level?
- Is the unit’s air fl ow unobstructed?
POWER:
Turn the device on/o
POWER
(ON/OFF)
Power Buttons may be found either on the
right of on the right of the LCD Panel or on the
Red Button of the remote control.
NOTES ON POWERING “ON”
TURNING THE COOLBOX ON THE FIRST TIME
The CoolBox Speed will be at Level 2 and the Cool Function will be listed as “On”the rst time
you power up your Cool-A-Zone CoolBox.
PRESSING “ON” DURING STANDBY
Turning the unit on during a state of stand-by will power up the CoolBox in the same mode
and airow setting in which it entered the stand-by mode. Make sure to adjust the settings
as appropriate for your comfort after coming back from stand-by.
SHOW
AIRFLOW
ANION
INDICATOR COOL
INDICATOR
SPEED
BUTTON
COOL
ON/OFF
POWER
ON/OFF
125
6 4 3
CZ-C100 Manual-rev.indd 4 8/1/12 10:48 AM

USING THE CoolBox TIMER
WHAT THE TIMER FUNCTION DOES:
1. Starts your Cool-A-Zone CoolBox cooler automatically after n hours from the stand-by state; OR,
2. Stops your Cool-A-Zone CoolBox cooler automatically after n hours from being turned ON.
NOTE: THE TIMER FUNCTION CAN ONLY BE SET BY THE HOUR.
USING THE TIMER:
1. Press theTIMER button.
2. You will notice that the TIMER button
begins to icker and you will see that“H x”
appears in the TEMPERATURE display.
3. To increase the number of hours, hit the
SPEED button on the panel or Increase
Airow button on the remotre control.
4. You cannot set the timer for more
than 9 hours.
5. Once the desired hours are set, do
not press any other buttons, after
5 seconds the TIMER will activate.
7 8
EVAPORATIVE AIR COOLER
COOLBOX CONTROLS (cont.)
USING YOUR COOLBOX
7. Timer Button: Activates the CoolBox TIMER feature, allowing you to either start the unit
from a start-up set after a certain number of hours or stop the unit after a certain
number of hours. More on this function on Page 9.
8. Anion Button: Turns the ANION function ON or OFF, as indicated by the Anion Indicator.
9. Remote Receiver LCD: Indicates a command received from the remote control.
12. Low Water Indicator:This warning light will let you know when it is time to rell your
CoolBox, and if the water gets too low, a buzzer will sound and the COOL mode will stop.
No buzzer will come on if you are in VENTILATION mode.
13. Show Ventilation Indicator: Indicates the level of ventilation being used by the
CoolBox.
14. Timer Indicator:When lit, indicates the TIMER function is active.
15. Swing Indicator: When lit, indicates the CoolBox SWING function is active.
ROUTINE MAINTENANCE
THE FOLLOWING ARE BEST PRACTICES FOR MAINTAINING YOUR COOLBOX:
1. Shell Cleaning:We recommend soap and water or a mild cleaner with a soft cloth.
Avoid abrasive cleaners or alcohol-based chemical cleaning agents.
2. Pad Cleaning: it is recommended you remove the pad and clean using a soft brush once every
two weeks (more frequent if being in used in a dust-heavy environment).
3. Draining theTank:We generally advise you drain water at the end of every day’s use to increase
longevity.
4. Tank Cleaning: we recommend that the tank be cleaned by hand on a schedule that suits your
needs best, especially in more humid climates or dust-heavy environments.
5. Storing the CoolBox: if you have been using your CoolBox and need to store it, please ensure
that you have cleaned and dried your tank, cleaned the drain outlet, cleaned the pad and shell,
and store covered until needed again.
Ensure that when doing any cleaning or maintenance, that your
Cool-A-Zone CoolBox unit is powered OFF and UNPLUGGED!
DISABLING THE TIMER:
1. Press theTIMER button.
2. Set the number of hours to“0”;
3. If you wish, you can also hit the POWER
button while theTIMER button is ickering.
4. Alternatively, you can hit the POWER
button after theTIMER has activated,
and then hit the POWER button again.
When in Stand-By mode, theTIMER
function will count down to power ON
the CoolBox. If the CoolBox is already on,
the TIMER function will count down to turn
OFF your CoolBox unit.
SHOW
VENTILATION
TEMPERATURE
DISPLAY
SWING
INDICATOR
TIMER
INDICATOR
LOW WATER
INDICATOR
SWING
ON/OFF
REMOTE
RECEIVER
TIMER ANION
ON/OFF
7 8 9 11 13
10 12 14 15
CZ-C100 Manual-rev.indd 5 8/1/12 10:48 AM

CoolAZone.com
EVAPORATIVE AIR COOLER
BASIC TROUBLESHOOTING
NO. Problem Possible Cause Solution
1. Air cooler does not work
2. No Cooling
3. No Airow
4. Unpleasant Odor
Power o or incorrect power connection
Controller breakdown
Fuse burnt
Electrical mainboard is broken
The pump is broken
No water or not enough water
The cool key on the controller is broken
Electrical mainboard is broken
The key on the controller is broken
The motor is broken
Dirty water
Dirty cooling pad
Power on or check and
connect power correctly
Replace it
Replace it
Replace it
Replace it
Add it
Replace the controller
Replace it
Replace the controller
Replace it
Change it to clean water
Clean it
Cool-A-Zone cannot be held liable for any modications made to the above circuit diagram by
any party, whether purchasor or third party. The above diagram is provided as a reference point
only for trained and skilled professionals and journeymen who have the knowledge to read circuit
diagrams, understand their meaning, and make such adjustments to fuses, circuits, and the like.We
recommend you contact Cool-A-Zone at info@coolazone.com if you have any questions.
DISCONNECT POWER BEFORE WORKING WITH THE FUSES OR CIRCUIT BOARD!
CoolBox Fast Facts
Three Speeds
Cooling Capacity..............1,050 sq. ft.
Maximum Air Delivery ....4,120 CFM
Fan Type ..........................Axial
Water Reservoir...............21 gallons
Width..............................30 in. / 76 cm
Height.............................55 in. / 140 cm
Depth..............................23 in. / 58 cm
Unit Weight.....................62 lbs. / 28 kg
Package Weight ..............72 lbs / 35 kg
55“
30“
CIRCUIT BOARD DIAGRAM
COOLBOX SPECIFICATIONS
9 10
DEBUGGING AND INSTALLATION CHECKLIST:
1. Inspect drain pipe for stable connection and assembly.
2. Check the water supply to be sure there is no leakage.
3. Check if the power supply connection is plugged in properly.
4. Check for debris in the water tank.
5. Check for any foreign matter in the air compressor.
6. Ensure that your outlet is properly rated / power source is correct.
7. Check for any shaking or odd vibrations when running the CoolBox.
CZ-C100 Manual-rev.indd 6 8/1/12 10:48 AM
Inhaltsverzeichnis

















