Cooper & Hunter SPRC-101 Bedienungsanleitung

Thank you for selecting C&H central air-
conditioner!
To ensure using the wireless remote controller
correctly, please read this manual carefully
before use, and keep it properly. For any
questions, please contact your dealer or our
service center.
14
3
1
1
1
Operation
Manual
Wireless Remote Controller
Model: SPRC-101
1
1. Before Installation
2. Mounting of Battery
1. Before Installation
2. Mounting of Battery
3. Instructions
4. Description
5. Signal Transmission
6. Operation
7. Installation
Contents
2

When your indoor unit does not support 3D/Ultra function, the
displays may not synchronize with each other when setting to it.
When cooperating with wired remote controller with signal
receiving function, the display may be inconsistent due to the
types of indoor unit when setting lower limit of temperature,
which is a normal phenomenon.
Please tick in the box "□" when confirmed no problem.
□1) Please check if the following items are complete.
1
1
2
□
①Pull out the cover.
②Insert the batteries.
Instructions
Mode: SPRC-101
To ensure using the controller correctly, please read this
manual carefully before use.
This manual should be read along with the installation manual
of air-conditioner (A/C).
Additional functions of this controller include Health, ECO,
Sleep, Boost, Electric Heater, Quiet, I Feel, and Wind-free,
Self-cleaning. If a function is not supported by your indoor unit,
when setting this function from the controller, the displays may
not synchronize with each other, which is a normal
phenomenon.
●
●The maximum transmission distance is about 5
meters, or even shorter when transmission path of IR signals
is not perpendicular to the receiver or when there is any
electronic lighting device nearby.
Wireless remote controller is a device transmitting
instructions, such as operation mode and time setting, to indoor
unit by pointing to the signal receiver on indoor unit and pressing
button to send IR signals.
●The controller supports the function to light up backlight
automatically. The backlight will light up when vibration
or shaking is detected by the controller.
Operation Manual for ireess eote ontroer
1. Before Installation
2. Mounting of Battery
3.
4. Description
Wireless remote controller
Name Quantity Application
Wireless remote controller
Holder
Screw (M4×16)
For operation and control
For holding the controller
For fixing the holder
1) Insert two AAA dry batteries inside the controller.
1) Take out the batteries if the controller is not
regularly used.
2) Please replace the two batteries simultaneously.
Please pay attention to the electrode when inserting
batteries.
1

Point the controller perpendicularly to
the receiver on indoor unit when
transmitting signals, and the signal
icon will keep flashing.
Signal transmission indication
Display screen
Display setting temperature, operating
time, position of louver, operation
mode and air volume type, etc.
All the icons are displayed here for
reference, the display will be different in
practice.
Button Description:
□Point signal transmitter on controller to the receiver on
indoor unit.
□
□When transmitting signals, the controller should be in a cone
range of 120 degree based on the receiver plane. When
indoor unit is mounted at a low elevation, the reception angle
becomes larger and transmission distance gets shorter,
which varies depending on the building structure.
□ As battery is exhausting, signal transmission distance will get
shorter, and might get failed to control /. n such case,
replace the batteries in time.
Operation of sending signals should be close to the indoor unit,
and make the controller perpendicular to the plane where the
receiver is located. If the plane is not perpendicular or
fluorescent light is used at this moment, the transmission
distance will be shorter.
Health ON/OFF
Temp "+" Temp "-"
Mode Fan
ECO Louver
Sleep Boost
Electric heater Quiet
Light
Timer 3D/Ultra
Signal transmission part
. ina ransission
2

□Please note: the ceiling ducted type A/C shown in the figure above
is taken as an example. Other types may vary from this one.
Signal receiver
Virtual line between signal
transmitter and receiver
Max. transmission
distance: 5m
Controller
●Signal receiver will beep when signal received. When
there is no beeping, the signal is not successfully
transmitted, please try again.
●Beep may not be heard due to interference of noises nearby.
Note: In some special cases, such as in centralized control
state, the signal is received but indoor unit does not operate,
at this point the buzzer gives a long beep for 1 second.
ON/OFF
For protection of the compressor, it should be powered on
12 hours before startup. Do not switch off the power source
when A/C is regularly used.
After the controller is powered on, the receiver LED will
keep flashing at every 0.5 second, which is a process of
initialization and no operation available, and then goes off.
□
●Do not place the controller at any location
with elevated temperature in case of
malfunction.
·Direct sunlight
· Nearby the stove
●Please be careful when using the controller,
otherwise it may break down if dropping
onto the ground or affected by damp.
When operating the controller, according to
[5. Signal transmission], the signal transmitter of controller
should point to the receiver on indoor unit, and operate by
pressing function buttons.
Tips
. Operation
Caution
3

●When heat mode stops, sometimes air-supply
operation will last for 2 minutes automatically.
Cool Dry Heat Fan Auto
The icons on screen will switch in the following
sequence at each press of Mode button
Point signal transmitter
on the controller to the
signal receiver, and press
Each press of
will increase the
temperature by 1°F ;
will decrease the
temperature by 1°F ;
Each press of
Temperature and Humidity
●ON/OFF operation should be performed at an interval
of min.3s, otherwise it may lead to a failure to actuate.
Mode
●When there are three levels of Dry operation, hold
"Mode+Fan" for over 3s when controller is OFF to
switch to "dC" unit type.
●When Auto-dry function is available, hold "Mode+Fan" for
over 3s when controller is OFF to switch to "AC" unit type.
ON/OFF
Point signal transmitter of the controller to
the signal receiver and press , the signal
receiver will beep once to indicate a
successful reception.
Mode Button
Temperature
.
4

●Humidity can be adjusted when in auto-Dry mode.
6-level:
(Breeze → SL → L → M
→
4-level:
( L → M → H → SH → AUTO )
Press
to set speed.
Each press of the button will adjust as
the following sequence:
3-level:
( L → M → H → AUTO )
(AUTO SH H
→
Point signal transmitter on
the controller to the signal
receiver, and press
.
Each press of
will increase the
humidity by 5% (max.
90%);
will decrease the
humidity by 5% (min.
35%).
Each press of
Fan
Louver
●In Dry mode, it is adjustable, but indoor unit is
defaulted at the level of Low.
●Auto-fan mode is available only when indoor unit
supports this function.
Louver setting when connected with 4-way cassette type
indoor unit.
●Angle of louver varies along with the types of indoor
unit. Please refer to the manual of indoor unit.
●The location of louver on screen may not match with
the actual location when the louver is swinging.
●In Cool and Dry modes, only Mode 1~5 are
available.
●Hold "Fan+ " for over 3s when the controller is
OFF to select Level 3, 4 or 6.
Humidity
Fan
5

1
1
2
Press "ON/OFF" to start operation, then
press "Louver" to adjust direction of air
flow. The louver will adjust as the following
sequence at each press.
Louver setting when connected with 3D panel.
Hold "Louver+Health" for over 3s to switch to "3d" for
controlling 3D panel.
3
When the controller is ON,
press "Louver", and the
icon of up&down air supply
flashes. During flashing,
press to adjust
the location of louver.
The icon stops flashing
after 5s, and the louver is
at the set location.
When the controller is ON,
press "3D/U.L." and the icon
is displayed, indicating
the louver is in 3D air supply
mode.
6
When the controller is ON,
press "Louver", and the icon
of up&down air supply
flashes, then press "Louver"
again, the icon of left&right
air supply flashes. During
flashing, press to
adjust the location of louver.
The icon stops flashing after
5s, and the louver is at the
set location.
6

Louver setting when connected with 1-way panel.
4
1
Hold "Louver+Health" for over 3s to switch to
"1F" to control 1-way panel.
2
3
When the controller is
, press "3D/U.." and
the icon is displaed.
Press "3D/U.." again and
the icon is displaed,
indicating the louver is in
ultrafar air suppl mode.
When the controller is ON,
press "Louver", and the
icon of up&down air supply
flashes. During flashing,
press to adjust
the location of louver.
The icon stops flashing
after 5s, and the louver is
at the set location.
When the controller is ON,
press "Louver", and the icon
of up&down air supply
flashes, then press "Louver"
again, the icon of left&right
air supply flashes. During
flashing, press to
adjust the location of louver.
The icon stops flashing after
5s, and the louver is at the
set location.
When the controller is ON,
press "3D/U.L." and the icon
is displayed, indicating
the louver is in 3D air supply
mode.
7

1
way cassette type indoor units
Louver unified setting:
when the controller is ON,
press "Louver", the icon of
up&down air supply flashes.
During flashing, press
to adjust the location of
louver.
The icon stops flashing after
5s, and the louver is at the
set location
2
3
(1) (2)
(1) (2)
Louver setting when connected with K3 4-way or K3 2-
Louver separate setting:
When the controller is ON, hold "Louver"
for over 3s to enter louver separate setting
mode. And the display of screen is as Fig.
(1), indicating that No.1 louver is in setting
state. Then press "Louver" again, the
display on screen is as Fig. (2), indicating
that No.2 louver is in setting state. (No.1~4
louvers available).
The display returns to common interface
when there is no operation within 5s.
Louver separate setting:
When the controller is ON, hold "Louver" for
over 3s. And the display of screen is as Fig.
(1), indicating the louver is in separate
setting state, and “01” means the first
louver to be set separately. Then press
"Louver" to select target louver, and adjust
louver by pressing . The display
returns to Fig (2) When there is no
operation within 5s.
Hold "Fan+Health" for over 3s to switch to "4F" to control the
louver.
8

●The setting content will be memorized, no repeat setting is
required in daily operation. If the setting has to be changed,
please refer to this page (setting of temperature, fan and
volume)
●Timed operation is to turn ON/OFF A/C after
a certain period of time.
●Timer can be switched on or off.
Functions
When there is a timer to be canceled, point the
signal transmitter on controller to the signal
receiver, and press . The receiver LED
goes off, indicating the Timer is canceled.
Additional Functions
Timed Operation
Press when the A/C is OFF, and the
A/C will turn on at set time.
Press when the A/C is ON, and the
A/C will turn off at set time.
Cancel Setting
When the timer is adjusted, point the signal
transmitter on controller to the signal
receiver, and press . The time on screen
will stop flashing, indicating a successful
setting, and the LED on the receiver lights up.
Press when the / is , the screen
displas that the / will turn in .h, and
the icon of .h flashes. he timer will be
adusted once at each press of or
when the icon is flashing.
The timer jumps by 0.5 hour interval within 10
hours; and 1 hour interval over 10 to max.23
hours.
Press when the / is , the screen
displas that the / will turn in .h, and
the icon of .h flashes, the time will be
adusted once at each press of or
when the icon is flashing.
When setting a imer, the one set last time will
displa on screen.
Timer
9
Inhaltsverzeichnis
Andere Cooper & Hunter Fernbedienung Handbücher
Beliebte Fernbedienung Handbücher anderer Marken

Panasonic
Panasonic EUR7622KB0 Bedienungsanleitung

Bang & Olufsen
Bang & Olufsen Beo4 Bedienungsanleitung

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Bedienungsanleitung

Multiplex
Multiplex PROFI TX 9 Bedienungsanleitung

One Remote
One Remote RMB4 Bedienungsanleitung

FUTABA
FUTABA 9ZAP - PART2 Bedienungsanleitung















