Cellular Data Modem & IP Router Series
User Manual
Version 1.0

2www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
Rev Version 1.0
Modem Use
The 615M-1 Series modems are designed and intended for use in fixed and mobile applications. “Fixed” assumes
the device is physically secured at one location and not easily moved to another location. Always keep the cellular
antenna a distance of at least 20 cm (8 in.) from anyone’s head or body while the modem is in use. This modem is
designed for use in applications that observe the 20 cm separation distance.
Interference Issues
Avoid possible radio frequency (RF) interference by following these guidelines:
• The use of cellular telephones or devices in aircraft is illegal. Use in aircraft may endanger operation and
disrupt the cellular network. Failure to observe this restriction may result in suspension or denial of cellular
services to the offender, legal action or both.
• Do not operate in the vicinity of gasoline or diesel fuel pumps unless use has been approved and authorized.
• Do not operate in locations where the device could interfere with medical equipment that may be in use.
• Do not operate in fuel depots, chemical plants, or blasting areas unless use has been approved and
authorized.
• Use care if operating in the vicinity of protected personal medical devices, such as hearing aids and
pacemakers.
• Operation in the presence of other electronic equipment may cause interference if the equipment is incorrectly
protected. Follow the installation recommendations provided by the equipment manufacturers.
Mobile Application Safety
• Do not change parameters or perform other maintenance on the 615M-1 modem while driving.
• Road safety is crucial. Observe national regulations for cellular telephones and devices while in vehicles.
• Avoid potential interference with vehicle electronics by correctly installing the 615M-1 modem. ELPRO
recommends installation by a professional.
UL Listed Models
When operating at elevated temperature extremes, the surface may exceed +70°C. For user safety, the
615M-1 should be installed in a restricted access location.
The SIM/SVC connectors are used for maintenance purposes only.
WARNING – EXPLOSION HAZARD, do not connect while circuit is live unless the area is known to be non-
hazardous.
Important Notice
ELPRO reserves the right to modify the equipment, its specification, or this manual without prior notice in the
interest of improving performance, reliability, or servicing. At the time of publication all data is correct for the
operation of the equipment at the referenced voltage and/or temperature. Performance data indicates typical values
related to the particular product.
No part of this documentation or information supplied may be divulged to any third party without the express
written consent of ELPRO. Products offered may contain software which is proprietary to ELPRO. The offer or
supply of these products and services does not include or infer any transfer of ownership.
Release Notice
This is the April 2013 release of the
615M-1 Cellular Data Modem & IP Router Series Manual
version 1.0, which
relates to version 5.0.2e modem firmware.

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
3Rev Version 1.0
Follow Instructions
Read this entire manual and all other publications pertaining to the work to be performed before installing,
operating, or servicing this equipment. Practice all plant and safety instructions and precautions. Failure to follow
the instructions can cause personal injury and/or property damage.
Proper Use
Any unauthorized modifications to or use of this equipment outside its specified mechanical, electrical, or other
operating limits may cause personal injury and/or property damage, including damage to the equipment. Any such
unauthorized modifications: (1) constitute “misuse” and/or “negligence” within the meaning of the product warranty,
thereby excluding warranty coverage for any resulting damage; and (2) invalidate product certifications or listings.

4www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
Rev Version 1.0
Chapter 1 - INTRODUCTION ...................5
1.1 Module Identification .....................5
1.2 Features and Benefits ....................5
1.3 General Specifications....................6
1.4 Mechanical Specifications .................8
1.5 Order Information........................9
1.6 External Connectors ....................10
1.7 Antenna ..............................11
1.8 Power Cable Pinout ....................11
1.9 RS-232 Serial Port Integration Parameters ..12
Chapter 2 - GETTING STARTED ...............13
2.1 Package Contents ......................13
2.2 Device Connections.....................13
2.3 LAN Configuration ......................14
2.4 Cellular Connections ....................15
Chapter 3 - 615M-1 WEB INTERFACE ..........16
3.1 Logging on to the Web Interface...........16
3.2 Unit Status ............................17
Status ...............................17
Identity ..............................20
Basic Settings.........................20
3.3 Cell Connection – 615M-1................22
Carrier ...............................22
GSM Settings .........................23
CDMA Settings ........................24
System Monitor........................27
Dynamic DNS .........................28
3.4 LAN Settings ..........................30
MAC Filtering .........................33
IP Filtering ............................34
3.5 Router ...............................37
Port Forwarding .......................37
Static Routes .........................38
3.6 Security ..............................39
PPTP ................................40
IPsec ................................41
GRE.................................44
3.7 Serial ................................44
External Serial .........................44
3.8 Diagnostics ...........................48
SNMP ...............................48
Logging ..............................50
3.9 I/O Settings ...........................51
Status ...............................51
Settings..............................52
Labels ...............................56
3.10 Firmware Update ......................56
Chapter 4 - IP ADDRESSING..................58
4.1 Overview .............................58
4.2 IP Addressing Tutorial ...................58
4.3 Private vs. Public IP Addresses............58
4.4 Port Forwarding ........................59
4.5 DMZ .................................59
4.6 Friendly IP Address .....................60
Chapter 5 - IPSEC AND VPN PASS-THROUGH
DEPLOYMENT GUIDE .......................61
7.1 Benefits of IPsec .......................61
7.2 615M-1 Configured IPsec Client ...........61
Cisco Router–VPN Server Configuration ....62
615M-1–IPSEC Client Configuration .......62
7.3 615M-1 Configured VPN Pass-through......63
615M-1–VPN Pass-Through Configuration ..64
Chapter 8 - USER I/O PORT ..................65
8.1 Circuit for Analog Inputs .................66
8.2 Simplified Circuit for Digital Input/Outputs ...66
8.3 Simplified Circuit for Mechanical Relays .....67
8.4 Inserting Wires into User Port Connector ....67
Appendix A - GLOSSARY ....................68
CONTENTS

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
5Rev Version 1.0
ChapTEr 1 - INTrODUCTION
The 615M-1 Series from ELPRO is the ideal solution for a wide range of cellular data network serial and Ethernet
connectivity requirements. All 615M-1 Series feature both high-speed 3G HSPA and EVDO cellular communications
in a single device, with full GSM and CDMA backward compatibility. The 615M-1 delivers two LAN, one serial, and
Rx diversity connections.
The GSM mode features a Tri-Band UMTS/HSUPA (850/1900/2100) and Quad-Band GSM/GPRS network support
with data rates up to 14.4Mbps downlink and 5.76Mbps uplink for HSPA, and is backward compatible to HSUPA,
HSDPA, EDGE and GPRS, dependent on carrier service availability.
The CDMa mode features EV-DO Rev A speeds with data rates up to 3.1Mbps downlink and 1.8Mbps uplink,
and is backward compatible to EV-DO Rev 0 and 1xRTT, dependent on carrier service availability. This occurs
automatically to the level of service available. Dual Band Digital CDMA 800MHz and CDMA PCS 1900MHz models
supports packet-switched services.
1.1 Module Identification
The module identification label is located on the bottom of your 615M-1 device. This label contains the product part
number, the serial number, FCC and IC identifications, as well as carrier specific information that is required when
activating your data account.
The module identification label contains information for GSM and CDMA:
• The GSM information contains an International Mobile Equipment Identity (IMEI) number in decimal format.
This number is used by the GSM network only to identify and validate the device. It has no permanent or semi-
permanent relation to the subscriber.
• The CDMa information contains the device MEID numbers. This number is required by your cellular carrier
when activating your data contract. The MEID number is provided in both decimal and hexadecimal formats.
The format required for activation is carrier dependent.
Figure 1 Module Identification Label
1.2 Features and Benefits
The 615M-1 Series provides the following features and benefits:
• Multiple carriers in a single device.
• Supports dynamic or static IP.
• Inbound and outbound Ethernet routing.
• DHCP server and inbound port mapping/translation (port forwarding).
• Firewall configuration for increased network security.
• Diversity antenna port/auxiliary port for increased receive sensitivity.
• Local or remote configuration using HTML web server.

6www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
Rev Version 1.0
• TCP/IP packet assembler and dis-assembler for serial connected devices.
• Inbound IP termination with static IP.
• Modem Domain Names with dynamic DNS.
• Internet access and web browsing via Ethernet connector.
• VPN support.
• On-board 1.8/3V SIM socket (active only for GSM).
1.3 General Specifications
Product specifications are subject to change without notice.
Table 1
Specifications
Transmitter/Receiver
Frequency
Quad-band 850/900/1900/2100 MHz/AWS(1,2)
Quad-band 850/900/1800/1900 MHz(3,4)
800 MHz Cellular/1900 MHz PCS/2100 MHz(5)
800 MHz Cellular/1900 MHz PCS/2100 MHz(6)
800 MHz Cellular/1900 MHz PCS(7)
Transmit Power (Max) 250 mW(1,2); 2 W(3,4); 250 mW(5,6,7)
Transmission UMTS, HSPA, EDGE, GPRS, EVDO Rev A (IS-856-A), 1xEVDO Rev 0 (IS-856), 1xRTT (IS-2000)
Modulation UMTS, HSPA, EDGE, GPRS, EVDO Rev A (IS-856-A), 1xEVDO Rev 0 (IS-856), 1xRTT (IS-2000)
Receive Sensitivity -109 dBm(1); -109 dBm(2); -105 dBm(3,4); -107 dBm(5,6,7)
Channel Spacing 5 MHz(1,2); 10 MHz(2); 1.25 MHz(5,6,7)
Data Rate
Downlink up to 384 kbps; Uplink up to 384 kbps(1)
Downlink up to 14.4 Mbps ; Uplink up to 5.76 Mbps(2)
Downlink up to 236 kbps; Uplink up to 236 kbps(3)
Downlink up to 115 kbps; Uplink up to 115 kbps(4)
Downlink up to 3.1 Mbps; Uplink up to 1.8 Mbps(5)
Downlink up to 2.4 Mbps; Uplink up to 153.6 kbps(6)
Downlink up to 153.6 kbps; Uplink up to 153.6 kbps(7)
Range (LoS) Cellular depends on service provider
Antenna Connector 2 x Female SMA Standard Polarity(1,2,3,4,5,6,7)
Input/Output
Discrete Input ON 2.3 Vdc, OFF 0.7 Vdc, 5.5 Vdc max(8)
Discrete Output NPN Transistor close to Digital Ground, Pull down 100-ohm(8)
Relay Outputs Max voltage 30 Vdc, Max current 1 A(8)
Analog Inputs Voltage input range 0 – 30 Vdc, Accuracy +/-0.2 Vdc(8)
Ethernet Port
Ethernet Port 10/100baseT; RJ45 Connector – 2 x IEEE 802.3 (auto MDIX)

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
7Rev Version 1.0
Specifications
Link Activity Activity LED
Serial
RS232 DB9 Female DCE
Data Rate (Bps) 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 76800, 115200 bps
Serial Settings 8 Data Bits; No Stop/1 Start/Parity (Configurable)
Protocols and Configuration
Protocols Supported
TCP/IP, UDP, ARP, ICMP, FTP, TFTP, TELNET, PING, GPS-
NMEA (optional), DHCP; MAC Filtering (Whitelist),
IP Filtering (Blacklist), DMZ, Dynamic DNS, Port Forwarding;
SNMP, HTTP embedded web server; IPsec, GRE Tunneling,
PPTP, VPN, RADIUS/802.1x
User Configuration Configuration and Firmware upgrades via HTTP/OTA (Over-the-Air)
Configurable Parameters Client/Router, Serial Client Server
Simultaneous RS232 connection
Security VPN, SIM Card PIN, RADIUS, IPsec
Bandwidth Protection MAC Address—Whitelist/Blacklist, IP Filtering—Whitelist/Blacklist
Network Management SNMP V2c, V3
LED Indication/Diagnostics
LED Indication RSSI; SVC; NET; GPS; AUX
Reported Diagnostics Diagnostics available through web pages
Compliance
EMC FCC Part 15; Industry Canada; CE; A-Tick
RF (Radio) EN 300 328; FCC Part 15
Hazardous Area Class I, Division 2
Safety IEC 60950-1
UL UL Listed
Environmental MIL-STD-810F
Approvals PTCRB, Carrier Specific Approvals
General
Size 109 x 153 x 45 mm (4.3 in x 6 in x 1.8 in)
Housing Powder-coated Aluminum
Mounting DIN Rail, Panel Mount (optional)
Terminal Blocks I/O: Removable terminal block, Screwless push-in wire, 18 - 28 AWG
Temperature Rating -30 to +70°C; -22 to +158°F
Humidity Rating 5 – 95% RH Non-condensing
Weight 1.13 kg (2.5 lb)

8www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
Rev Version 1.0
Specifications
Power Supply
Nominal Supply 9 to 28 Vdc; Under/Over Voltage Protection and Reverse Polarity
Molex 43025-0400 4-pin locking connector
Average Current Draw 130 mA @ 13.8 Vdc (Idle)
Transmit Current Draw 350 mA @ 13.8 Vdc
NOTE Specifications subject to change.
1 UMTS
2HSPA
3EDGE
4GPRS
5EVDO Rev A (IS-856-A)
61xEVDO Rev 0 (IS-856)
71xRTT (IS-2000)
8Access via SNMP only
1.4 Mechanical Specifications
This section describes the exterior dimensions of the 615M-1 modem. A DIN rail mounting plate (not shown) is
provided with the modem, and needs to be fitted to the modem using the screws and toothed washers provided,
as described in the installation instructions. The mounting plate can be used to secure the modem to any surface
that can be drilled for such purpose.
The following drawings may be used as layout reference before proceeding with the mounting process.
1.68
2.55 4.28 4.53
4.05
4.50
4.05
1.90 2.18
6.00
Bottom View Product View
1.68
2.55 4.28 4.53
4.05
4.50
4.05
1.90 2.18
6.00
Front View Side View
Figure 2 615M-1 Mechanical Drawings

www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
9Rev Version 1.0
1.5 Order Information
Table 2
Order Code Description
615M-1 3G Modem, GSM/CDMA
Table 3
Product Code Description Data Sheet
Antennas–Cellular
WHGSM-3 Cellular Antenna, 130 mm (5 in.), SMA Male, Magnetic Base Mount, 2 dBi gain 7941
Cables
CC3/10-SMA Coaxial Cable Kit, 3 m (9.8 ft)/10 m (32 ft), N-type to SMA 7932
7947
CCTAIL-SMA-F/M Coaxial Cable Tail, 600 mm (24 in.), SMA to N-type Female or Male 7951
SER-RJ45 Configuration Cable, RS232 Serial, DB9 Female to RJ45 7956
SER-DB9NULL RS232 Serial, Null Modem 7988
ETH-C5X Ethernet Cable, 1.8 m (6 ft), Crossover, RJ45 to RJ45 7952
ETH-C5A Ethernet Cable, 1.8 m (6 ft), Direct, RJ45 to RJ45 7953
Surge Diverters
CSD-SMA-2500 SMA Surge Diverter for use with CC10, CC20 - SMA 7959
CSD-N-6000 Coaxial Surge Diverter, Bulkhead N Female to N Female 7960
IOP32D Signal Surge Diverter, 2 wire/4 wire 7961
Power Supply
PS-WW-XP 100Vac Input Power Supply 7934
PS-DINAC-12DC-OK DIN Rail Power Supply, 100 - 250 Vac, 12 Vdc/2.5 A 7935
PS-DINAC-24DC-OK DIN Rail Power Supply, 100 - 250 Vac, 24 Vdc/2A 7958
Mounting Brackets
BR-615-DINCLIP DIN Rail Mount Kit for 615M-xx Series 7986
BR-615-PLATE Panel Mounting Plate Kit: for 615M-xx Series 7987

10 www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
Rev Version 1.0
1.6 External Connectors
Table 4 describes the external connectors for the 615M-1 modem.
Figure 3 Front Panel Connections
SIM Slot
Mini-USB
Service Port
Eject
I/0
2 Digital Inputs/Outputs
2 Analog Inputs
2 Outputs (relay driven)
Figure 4 Rear Panel Connections
Table 4 External Connectors
Panel Indicator Connection Description
COM RS-232 Serial to IP conversion use
ANT SMA Primary RF antenna
AUX SMA Cellular diversity
LAN 1, LAN 2 RJ-45 Interface for Ethernet connection to devices
SIM/SVC USB Mini Available for ELPRO support use only
Inhaltsverzeichnis
Andere Cooper Bussmann Modem Handbücher
Beliebte Modem Handbücher anderer Marken

Davicom
Davicom DM562AP Bedienungsanleitung

EpiValley
EpiValley TATA indicom SXC-1080 Bedienungsanleitung

Zte
Zte WiMAX Bedienungsanleitung

Intelimax
Intelimax MA-2060 Bedienungsanleitung

SMC Networks
SMC Networks D3CM1604V Gebrauchs- und Pflegehandbuch

Telstra
Telstra Wi-Fi 4G Advanced Pro X Bedienungsanleitung

US Robotics
US Robotics 3453C Bedienungsanleitung

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Bedienungsanleitung

Zte
Zte MF823 Bedienungsanleitung

Four-Faith
Four-Faith F1403 Bedienungsanleitung

Sierra Wireless
Sierra Wireless AIRLINK MP595W Bedienungsanleitung

Gemtek
Gemtek WiMAX WIXFBR-103 Bedienungsanleitung