- 10 -
In its factory default setting, the radiant element will
be allowed to operate for up to 2 hours after the
beginning of the off peak charge period to maintain a
comfortable room temperature if required. After 2 hours the
radiant element will be automatically disabled until the end
of the off peak charge period.
In circumstances where it will not be necessary to maintain
a high ambient room temperature between the hours of
typically 12am and 2am (for example a commercial
application) this feature can be disabled by removing the
time delay pin on the power enable board (see Fig. 19B),
which will automatically switch the radiant element off at the
beginning of the off peak charge period.
19A
19B
RADIANT ELEMENT OVERRIDE
REASSEMBLY
Reconnect the radiant
element connector as
shown in Fig 20A. Replace the
outer front panel by hooking
onto the two location clips on
the top panel Fig. 20B, 20C&
20D. Swing the bottom of the
front panel gently towards the
radiator Fig. 20Eand carefully
make sure any excess cable
is fed through into the base of
the radiator Fig. 20F. When
securing the front panel with
the screws provided, ensure
the right hand corner is
secured first to avoid trapping
the cable.
20C
20D
If the direct acting mains supply connection is to be made
on the left hand side of the radiator the pre-wired cable
must be passed behind the feet and secured using the clips on
the base of the radiator. Two sets of clips are already attached
to the base of the radiator to allow the mains cables to travel
parallel to each other, if required. See also Section 4 and Fig. 4.
Cut the mains cables to length. Ensuring the
electricity supply is disconnected, connect the free
end of the mains cable to a suitable double pole switch
adjacent to the radiator – reinstate the electricity supply.
Note – the double pole switch must have a contact
separation of at least 3mm in all poles.
ON NO ACCOUNT SHOULD ANY SURPLUS CABLE BE PUSHED INSIDE OR BEHIND THE RADIATOR.
CHECK ALL ELECTRICAL CONNECTIONS FOR TIGHTNESS.
21 22
20E
20A
20F
20B