3
(For California Residents)
WARNING: These products can expose you to chemicals including LEAD and DEHP which are known to the state of California to cause cancer and birth defects or other reproductive harm. For more
information go to www.P65WARNINGS.CA.GOV. Wash hands following installation or handling.
1. SAFETY INSTRUCTIONS
• Warning: Do not touch exposed cables w/your bare hands when operating the refrigerator/freezer
• Warning: It is dangerous to touch the plug with wet hands. When using the refrigerator/freezer
in a vehicle or boat, please make sure the electricity has a fuse if using the main power source.
• TheinstallationofaDCpowersourceonaboatshouldbehandledbyqualiedpersonnel
• Make sure the voltage is correct.
• Do not place any electrical devices inside the refrigerator/freezer
• Pleasekeeptherefrigerator/freezerawayfromanysubstancethatmaycauseelectrocutionorre
• The refrigerator/freezer is not intended for use by young children without adult supervision
• Do not turn the refrigerator/freezer upside down to drain liquids. Use the drain plug and a dry cloth
• Do not put any objects in the air inlet or outlet vents
• Turn off and disconnect the refrigerator/freezer from the power source before cleaning
2. NOTES ON USING THE PRODUCT
• Your refrigerator/freezer requires good ventilation, especially around the back of the unit. Allow
a gap of at least 8 inches (200mm) around the back and 4 inches (100mm) on the other sides
• Avoid humidity: Humidity inside the refrigerator/freezer can form frost and impair cooling. Defrost
the refrigerator/freezer before frost is formed. Never clean the refrigerator/freezer under running
water or immerse in water
• Avoid placing your refrigerator/freezer near a heat source. This will help the refrigerator/freezer to
workmoreefcientlyandkeepitscontentscool
• Placetherefrigerator/freezeronaatsurfaceandawayfromanyledges.Whenplacingthe
refrigerator/freezer into a vehicle, use straps to fasten it securely
3. OPERATING INSTRUCTIONS
• POWER: The refrigerator/freezer controls the compressor system and adds battery
protection. When the input voltage is at minimum value, it will stop the compressor; when the
voltage comes back to the normal value, the compressor will automatically restart
• BATTERY PROTECTION: Selectlow,medorhighsettings.Belowyoucanndthebatteryvoltage
levels values when the compressor stops running (cut-out) & when the compressor restarts (cut-in)
BATTERY ELECTRIC POWER
DISPLAY IF CONNECTED TO
W59 PORTABLE BATTERY
BATTERY
PROTECTION 12V CUT-OUT 12V CUT-IN 24V CUT-OUT 24V CUT-IN
LOW 8.5V 10.9V 21.3V 22.7V
MED 10.1V 11.4V 22.3V 23.7V
HIGH 11.1V 12.4V 24.3V 25.7V