zDo not wear metallic rings, watchbands, ear, nose, lip rings or other metallic devices while
installing or troubleshooting photovoltaic systems.
zUse only insulated tools that are approved for working on electrical installations.
zAbide with the safety regulations for all other components used in the system, including wiring
and cables, connectors, charging regulators, inverters, storage batteries and rechargeable
batteries, etc.
zUse only equipment, connectors, wiring and support frames suitable for a solar electric system.
Always use the same type of module within a particular photovoltaic system.
zThe electrical characteristics are within ±3 percent of the indicated values of Isc, Voc, and Pmax
under standard test conditions (irradiance of 1000W/m2, AM 1.5 spectrums, and a cell
temperature of 25°C (77°F)
zUnder normal outdoor conditions the module will produce current and voltages that are different
than those listed in the date sheet. Data sheet values are values expected at standard test
conditions. Accordingly, during system design, values of short-circuit current and open-circuit
voltage should be multiplied by a factor of 1.25 when determining component voltage ratings,
conductor ampacity, fuse ratings and size of controls connected to the modules or system output.
zFire Resistance rated Class is Class C.
2、Product Identification
Each module has four labels providing the following information:
zNameplate:describes the product type,rated power,rated current,rated voltage,open circuit
voltage,short circuit current,all are measured under STC;weight,dimension,the maximum
system voltage,the maximum fuse rating and power tolerance are all shown on the nameplate.
Generally,power tolerance is ±3%。
zBarcode: each module has a unique serial number. The serial number has 16 digits. The