Cusam Coding Intercom Bedienungsanleitung

www.cusamintercom.com
0
CODING
CODING
CODING
CODING
INTERCOM
INTERCOM
INTERCOM
INTERCOM
USER
USER
USER
USER
’
’
’
’
S
S
S
S
MANUAL
MANUAL
MANUAL
MANUAL

www.cusamintercom.com
1
Contents
Section Description page
Ⅰ 、 System instruction -------- ---------------------------- ------ 2-6
▲
▲
▲
▲
Main Products -------- ------------------------------- ------ 2-3
▲
▲
▲
▲
Description of indoor phone ------- ------------------------ 4
▲
▲
▲
▲
Description of Door station ------- -------------------------5
▲
▲
▲
▲
System features------- ---------------------------------------6
Ⅱ 、 Technical parameter------- --------------------------- ----- -- - -6
Ⅲ 、 Code setting----------- ---------------------------- ----------- 7-9
Ⅳ 、 Use method and problem dealing-- -------------------- - -9-14
Ⅴ 、 System schematic and wiring diagram--------------- - - 15-16
Ⅵ 、 Door station setting order---- ------------------------------ -- 17
Ⅶ 、 User
’
s operational order-- ------------------------------- ----- 18
Ⅷ 、 Wrong code form----------- ------------------------------ ----- 18
Ⅸ 、 Attentions----------------- ----------------------------- ----- 19-21

www.cusamintercom.com
2
1
1
1
1
、System
System
System
System
instruction
instruction
instruction
instruction
Coding video and audio intercom system mainly consist s of
the door station, the module, indoor phone s , the power source
and so on, which is extremely suit for the high building .
▲
▲
▲
▲
Main
Main
Main
Main
Products
Products
Products
Products
Door station

www.cusamintercom.com
3
Indoor phones

www.cusamintercom.com
4
▲Description
Description
Description
Description
of
of
of
of
indoor
indoor
indoor
indoor
phone
phone
phone
phone
Location
Description
Function
1
4″/7 ″Indoor phone Screen
Identify Visitor
2
Power Light
Indicates Power On
3
Monitor Button
View Picture On Indoor phone
4
Call/Alarm( Alarm may choose )
Button
Activate Alarm
5
Unlock Button
Operate Electric Door Lock
6
Microphone
Speak to Visitor
7
Talk Button
Telephone conversation
8
Brightness
Adjust brightness of Indoor
phone
9
Contrast Adjustment
Adjust contrast of Indoor phone
10
Receiver
Listen to Visitor

www.cusamintercom.com
5
▲Description
Description
Description
Description
of
of
of
of
Door
Door
Door
Door
station
station
station
station
Location
Description
Function
1
Camera Lens
Sends Picture
To
Monitor
2
Night Vision Light
(LED Light)
Illuminates Area In Darkness
3
Speaker
Enables
You To
Speak
To
Visitor
4
Door Bell Button
Pressing Gives Ding Dong Sound
5
Microphone
Enables Visitor
To
Speak
To
You

www.cusamintercom.com
6
▲
▲
▲
▲
System
System
System
System
features
features
features
features
LED inside the door station provides a clear picture even at
night.
It is with all functions and features that video and audio coding
intercom system have
Video indoor phones can be installed with audio indoor phones
together, which is very flexible and convenient.
Ⅱ、Technical
Technical
Technical
Technical
parameter
parameter
parameter
parameter
·Working voltage :DC10.8V ~ 16V
·The undistorted power of output:
The main channel: 5mw min
The reply channel: 100mw min
·Frequency response :300 ~ 3400HZ ± 3db
·Environment temperature :-40 ℃to +70 ℃
·Humidity :45% to 95%
·Working current of camera :500mA ± 20mA
·Camera :1/3 ″CCD
·Definition :380 TV Line

www.cusamintercom.com
7
Ⅲ 、 Code
Code
Code
Code
setting
setting
setting
setting
1
1
1
1
. Press**00,XXXX and enter into the coding state.(the original
password of the manager is 2098)
2.
2.
2.
2.
Press **02 to change the coding state into “ 0 ” .
3.
3.
3.
3.
Using order code **16 to set the number of dialing,it depends on
the floors (If it is over 9 floor,please use mixed dialing. Set code “ 7 ” ,you
can dial three and four number mixly). Please press "#" to exit
programming.
The quick establishing of the extension phone number:
(Recommendation )
☆The door station provides a quick order "**41" if the room number
encoding method conforms to the rule of table 1, Just do as
follows:press **00, XXXX (manager password), **41, then it will
come to the programming rule as table one does.
☆The door station provides a quick order "**42" if the room number
encoding method conforms to the rule of table 2,

www.cusamintercom.com
8
☆
The door station provides a quick order "**43" if the room number
encoding method conforms to the rules of table 3.Use order “ **40 ” to
eliminate the comparative table of the module address and the room
number".
☆
The manipulating setting of the extension phone number: press **15
and come up with Y011 after completes steps 1, 2, 3 (Y stands for the
address, the 2
nd
and 3
rd
figure stand for the coding site, and the 4
th
figure
is the room number).Entering three numerals if you want to revise the
address, and press the key "*" if you don ’ t want to. It ’ ll show four
numerals after finishing the above steps.Please enter four numerals to
revise (namely room number), press "* " if do not revise (namely
examination), and then it will demonstrate the next encoding address. If
the four figures have been in table (namely repetition), and it ’ ll show
the repetitious number address. Then please enter 0000,that mean you
don't use this address.
☆
The module(see the picture in the right corner),
the address of module ranges from 0101 to 9904.
Namely the coding sites are 01 to 99 (namely
floors are 01 to 99), room number are 01 to 04.
The first 8,421 is decimal and the latter 8,421 is
the single. T here are eight pairs of two sides
contact pin.

www.cusamintercom.com
9
Coding site 01 (the first floor): the block of short-circuits should be
inserted in the single
1
contact pin
Coding site 03 (the third floor): the block of short-circuits should be
inserted in the single
1
and 2 contact pin.
Coding site 06 (the sixth floor): the block of short-circuits should be
inserted in the single 2 and 4 contact pin.
Coding site 19 (the nineteenth floor): the block of short-circuits should
be inserted in the single
1
and 8 and decimal
1
contact pin.
The room number 01-04 should be inserted in R01, R02, R03, R04
accordingly.
(for example) If the room number you want is 1301, insert the block
of short-circuits to the single
1
and 2 and decimal 1,and the room number
cut over to R01 then. The comparative table of room number and module
address, see details in 6,and 7 pages,
Ⅳ 、 Use
Use
Use
Use
method
method
method
method
and
and
and
and
pro
pro
pro
pro
blem
blem
blem
blem
dealing
dealing
dealing
dealing
1.
1.
1.
1.
The visitor can input the room number directly when he /she comes.
Press “ # ” to eliminate and re-input when you input wrong number, then the
extension telephone will have the ring sound. meanwhile, the indoor phone
Dieses Handbuch passt für folgende Modelle
16
Inhaltsverzeichnis
Andere Cusam Gegensprechanlage Handbücher